Loading...
HomeMy WebLinkAboutLAKEVIEW ON THE RISE SUBDIVISION - Filed FDT-FIELD DENSITY TEST - 2019-08-08FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 20181040.0253 07/26/19 07/31/19 Earthwork 1901 Sharp Point Dr, Ste C Fort Collins, CO 80525-4429 970-484-0359 Client Signature Construction LLC Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 Lakeview on the Rise Apartment Development 6740 South College Avenue Fort Collins, CO Project Project Number: 20181040 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description Test Method (pcf) 1 20181040.0153 Dark Brown Clay ASTM D698 19.0 113.4 18.0 - 22.0 Min 95 Field Test Data No. Test Location Elev. No. Test Lift / Mat. Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in) (pcf) (pcf) (pcf) Debera Dr Sewer backfill 368 15' North of Rick Dr and Debra Dr intersection HMAC FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: Client 20181040.0255 07/29/19 08/01/19 Asphalt Revision 1 - enter compaction specs Signature Construction LLC Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 1901 Sharp Point Dr, Ste C Fort Collins, CO 80525-4429 970-484-0359 Lakeview on the Rise Apartment Development 6740 South College Avenue Fort Collins, CO Project Project Number: 20181040 Lab Test Data Comp. Max. Project Requirements Comp. Min. Mat. Material Information Thickness Min. Density Reference Laboratory No. Reference Number Classification and Description Test Method (pcf) (in) (%) (%) 1 Connell Mix 154.2 92 96 Field Test Data Test Pave. Mat. Density Length Nuclear Core Density Core Factor Correction Density Corrected Comp. No. Test Location Lift No. (%) Core Data (pcf) (in) (pcf) (pcf) (pcf) Triliby Sewer backfill top mat 21 100' East of Debra Dr and Triliby intersection Top 1 142.8 93 22 110' East of Debra Dr and Triliby intersection Top 1 142.9 93 23 10' East of Debra Dr and Triliby intersection FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 20181040.0259 07/30/19 08/02/19 Earthwork 1901 Sharp Point Dr, Ste C Fort Collins, CO 80525-4429 970-484-0359 Client Signature Construction LLC Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 Lakeview on the Rise Apartment Development 6740 South College Avenue Fort Collins, CO Project Project Number: 20181040 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description Test Method (pcf) 1 20181040.0153 Dark Brown Clay ASTM D698 19.0 113.4 18.0 - 22.0 Min 95 Field Test Data No. Test Location Elev. No. Test Lift / Mat. Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in) (pcf) (pcf) (pcf) Rick Dr Sewer backfill 373 35' West of Rick Dr and Debra Dr intersection -1' 1 8 131.4 21.0 19.0 110.4 97 374 45' West of Rick Dr and Debra Dr intersection -3' 1 8 127.9 20.1 18.6 107.8 95 375 49' West of Rick Dr and Debra Dr intersection -4' 1 8 128.0 19.6 18.1 108.4 96 Comments: Datum: Std. Cnt. M: 622 Std. Cnt. D: 2280 Test and/or retest results on this report meet project requirements as noted above. S/N: 60674 Make: Troxler Model: 3430 Last Cal. Date: 01/31/2019 Services: Reported To: Contractor: Juan with Connell Connell Craig L. Nelson Project Manager Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt Reviewed By: Terracon Rep.: Douglas Novosad Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1 Top 1 142.6 92 Comments: Datum: Std. Cnt. M: 617 Std. Cnt. D: 2285 Test and/or retest results on this report meet project requirements as noted above. S/N: 60674 Make: Troxler Model: 3430 Last Cal. Date: 01/31/2019 Services: Perform in-place density tests to determine degree of compaction. Reported To: Contractor: Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt Taylor w/ Signature Construction Connell Craig L. Nelson Project Manager Reviewed By: Terracon Rep.: Douglas Novosad Test Methods: ASTM D2950 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0025, 11-16-12, Rev.6 Page 1 of 1 -3' 1 8 132.5 20.8 18.6 111.7 99 369 10' North of Rick Dr and Debra Dr intersection -2' 1 8 133.5 21.1 18.8 112.4 99 370 8' North of Rick Dr and Debra Dr intersection -1' 1 8 134.0 21.5 19.1 112.5 99 Comments: Datum: Std. Cnt. M: 627 Std. Cnt. D: 2295 Test and/or retest results on this report meet project requirements as noted above. S/N: 60674 Make: Troxler Model: 3430 Last Cal. Date: 01/31/2019 Services: Reported To: Contractor: Juan with Connell Connell Craig L. Nelson Project Manager Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt Reviewed By: Terracon Rep.: Douglas Novosad Test Methods: ASTM D6938 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1