Loading...
HomeMy WebLinkAboutLAKEVIEW ON THE RISE SUBDIVISION - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - 2019-10-17Report Number: Service Date: Report Date: Task: Client Fort Collins, CO 6740 South College Avenue Signature Construction LLC Lakeview on the Rise Apartment Development Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 970-484-0359 Fort Collins, CO 80525-4429 1901 Sharp Point Dr, Ste C Concrete 20181040.0362 09/16/19 10/14/19 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 20181040 Specified Strength: 28 days Mix ID: Supplier: Batch Time: Truck No.: A4305 Martin Marietta Materials Material Information 0718 1729 Plant: Ticket No.: Rigden 49163988 Field Test Data Test Air Content (%): Result Specification 4 3-5 5.0 5-8 78 68 141.8 4,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: 09/16/19 Sample Time: 0820 Quinn Zamora Clear 10/60 60 Sample Location: See attachment. CONCRETE COMPRESSIVE STRENGTH TEST REPORT Report Number: 20181040.0362 Service Date: 09/16/19 1901 Sharp Point Dr, Ste C Report Date: 10/14/19 Revision 1 - 28-day results Fort Collins, CO 80525-4429 Task: Concrete 970-484-0359 Client Project Signature Construction LLC Lakeview on the Rise Apartment Development Attn: Matt Boyle 6740 South College Avenue 720 3rd Ave SW Fort Collins, CO Carmel, IN 46032-2036 Project Number: 20181040 Services: Terracon Rep.: Quinn Zamora Reported To: Taylor w/ Signature Construction Contractor: Connell Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Martin Marietta Materials Inc, Bill Meek (1) Martin Marietta Materials Inc, Matt Hysen Reviewed By: ____________________________________ (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine Craig L. Nelson (1) Terracon Consultants, Inc., Eric Bernhardt Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10-16-13, Rev.10 Page 1 of 1 Placement Method: Chute Water Added Before (gal): Water Added After (gal): Accumulative Yards: Batch Size (cy): Driveway pan, curb, and gutter. (see attachment) Placement Location: Laboratory Test Data Set Avg Diam. Area Date Weight Date Test Age at Load Maximum Strength Compressive Fracture No. ID Specimen (in) (sq in) Received Tested (days) (lbs) (psi) Type Tested (lbs) By 38 1 4.00 12.57 09/17/19 8.66 09/23/19 7 70,100 5,580 3 38 2 4.00 12.57 09/17/19 8.66 10/14/19 28 82,740 6,580 3 38 3 4.00 12.57 09/17/19 8.62 10/14/19 28 88,450 7,040 3 38 4 4.00 12.57 09/17/19 8.62 10/14/19 28 86,990 6,920 3 Average (28 days) 6,850 Initial Cure: Outside Final Cure: Moist Room Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Services: Reported To: Contractor: Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Martin Marietta Materials Inc, Bill Meek (1) Martin Marietta Materials Inc, Matt Hysen (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt Craig L. Nelson Project Manager Connell Taylor w/ Signature Construction Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064 Terracon Rep.: Quinn Zamora The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 11-16-12, Rev.6 Page 1 of 1