Loading...
HomeMy WebLinkAboutLAKEVIEW ON THE RISE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - 2019-09-26Report Number: Service Date: Report Date: Task: Client Fort Collins, CO 6740 South College Avenue Signature Construction LLC Lakeview on the Rise Apartment Development Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 970-484-0359 Fort Collins, CO 80525-4429 1901 Sharp Point Dr, Ste C Concrete 20181040.0344 09/07/19 09/17/19 Revision 1 - 7-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 20181040 Specified Strength: 28 days Mix ID: Supplier: Batch Time: Truck No.: A4305 Martin Marietta Materials Material Information 0614 1917 Plant: Ticket No.: 49163652 Field Test Data Test Air Content (%): Result Specification 4 1/2 3-5 5.0 4.5-7.5 76 65 147.4 4,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: 09/07/19 Sample Time: 0720 Shannon Cargile Sunny 10/30 10 Sample Location: Station 24+93.5 Placement Method: Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards: Batch Size (cy): Placement Location: Curb and Gutter, North Site Entryway Laboratory Test Data Set Avg Diam. Area Date Weight Date Test Age at Load Maximum Strength Compressive Fracture No. ID Specimen (in) (sq in) Received Tested (days) (lbs) (psi) Type Tested (lbs) By 36 1 4.00 12.57 09/09/19 8.54 09/09/19 2 51,440 4,090 3 BA 36 2 4.00 12.57 09/09/19 8.62 09/14/19 7 69,230 5,510 3 BA 36 3 09/09/19 8.60 10/05/19 28 36 4 09/09/19 8.64 10/05/19 28 36 5 09/09/19 8.62 10/05/19 28 Initial Cure: Onsite Cooler Final Cure: Moist Room Comments: Samples Made By: Terracon Services: Reported To: Contractor: Report Distribution: (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Martin Marietta Materials Inc, Bill Meek (1) Martin Marietta Materials Inc, Matt Hysen (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt Todd A. Turney Department Manager Connell Taylor w/ Signature Construction Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064 Terracon Rep.: Shannon Cargile The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 11-16-12, Rev.6 Page 1 of 1