HomeMy WebLinkAboutEAST RIDGE FILING PHASE 6 - Filed CT-CONCRETE TEST - 2019-09-12Soilogic, Inc.
3522 Draft Horse Court • Loveland, CO 80538 • (970) 535-6144
August 20, 2019
Coyote Ridge Construction, LLC
PO Box 3128
Loveland, Colorado 80539
Attn: Mr. Ken Baty
Re: Construction Materials Testing and Observation Services Report
East Ridge Subdivision Phase 6
Fort Collins, Colorado
Soilogic Project # 16-2046
Mr. Baty:
During the period of April 4 through July 27, 2018, Soilogic Inc. (Soilogic) provided
construction materials testing and observation services for the referenced project. Our
services were provided on a part-time basis and included the observation and testing of
concrete delivered to the site for placement and asphaltic concrete placed during paving of
the site roadways. Results of the observation and testing services completed during the
referenced period are included with this report.
During the referenced period, Soilogic personnel observed and tested cast-in-place
concrete delivered to the site for construction of inlets, curb and gutter and sidewalks. The
testing completed in the field included slump, air content, unit weight, concrete
temperature, and ambient air temperature at the time of placement. Test cylinders were
molded from representative samples of the plastic concrete for laboratory curing and
compressive strength testing. Results of the field and laboratory tests performed during
the referenced period are included with this report. Results of laboratory concrete
compressive strength tests completed during the referenced period are also included and
will be provided as they become available.
During the site paving operation, Soilogic personnel obtained two (2) representative
samples of the asphaltic concrete being placed for laboratory evaluation. The laboratory
testing performed on the obtained samples included Rice value (ASTM D-2041) asphalt
content by ignition (ASTM D-6307) and washed sieve analysis/gradation (ASTM C-117
and C-136) tests.
Construction Materials Testing and Observation Services Report
East Ridge
Fort Collins, Colorado
Soilogic # 16-2046
2
The completed laboratory testing performed on the asphaltic concrete samples indicated
those materials met the project gradation and asphalt content specifications.
During and after compaction of the asphaltic concrete, density tests were completed on the
in-place pavement using a portable nuclear density gauge in general accordance with
ASTM specification D-2950. The nuclear density tests were completed at random
locations across the pavement surface. Results of the completed field density tests are
outlined on the attached summary sheet. The final completed asphaltic concrete field
density tests met the project compaction requirement of 92 to 96% of the materials Rice
value.
We appreciate the opportunity to be of service to you on this project. If you have any
questions concerning the enclosed information or if we can be of further assistance to you
in any way, please do not hesitate to contact us.
Very Truly Yours,
Soilogic, Inc. Reviewed by:
Jason Horner, E.I. Wolf von Carlowitz, P.E.
Project Engineer Principal Engineer
Maximum
143.9 154.2 93% 92-96% Pass
154.2 94% 92-96% Pass
7/27 12 Top Marquise - 70' N of Conquest -
7/27 11 Top Marquise - @ Coleman - 145.1
143.8 154.2 93% 92-96% Pass
154.2 92% 92-96% Pass
7/27 10 Top Coleman - 160' E of Yeager -
7/27 9 Top Marquise - 25' S of Barnstormer - 142.4
143.8 154.2 93% 92-96% Pass
154.2 94% 92-96% Pass
7/27 8 Top Marquise - 15' N of Biplane -
7/27 7 Top Biplane - 125' E of Yeager - 144.5
144.3 154.2 94% 92-96% Pass
154.2 93% 92-96% Pass
7/27 6 Top Navion - 100' N of Conquest -
7/27 5 Top Yeager - 80' N of Coleman - 143.6
143.9 154.2 93% 92-96% Pass
154.2 92% 92-96% Pass
7/27 4 Top Yeager - 90' S of Barnstormer -
7/27 3 Top Navion - 85' S of Barnstormer - 142.2
143.4 154.2 93% 92-96% Pass
154.2 93% 92-96% Pass
7/27 2 Top Vicot Way - 110' S of Barnstormer -
7/27 1 Top Vicot Way - 90' N of Conquest - 143.0
144.0 153.9 94% 92-96% Pass
153.9 94% 92-96% Pass
7/10 15 Bottom Navion - 100' N of Conquest -
7/10 14 Bottom Navion - 100' S of Barnstormer - 144.5
146.3 153.9 95% 92-96% Pass
153.9 94% 92-96% Pass
7/10 13 Bottom Vicot Way - 100' N of Conquest -
7/10 12 Bottom Vicot Way - 80' S of Barnstormer - 143.9
144.3 153.9 94% 92-96% Pass
153.9 94% 92-96% Pass
7/10 11 Bottom Barnstormer - 60' W of Navion -
7/10 10 Bottom Barnstormer - 40' W of Yeager - 145.3
143.0 153.9 93% 92-96% Pass
153.9 96% 92-96% Pass
7/10 9 Bottom Yeager - 75' S of Biplane -
7/10 8 Bottom Yeager - 80' S of Barnstormer - 147.2
146.5 153.9 95% 92-96% Pass
153.9 93% 92-96% Pass
7/10 7 Bottom Barnstormer - 120' W of Marquise -
7/10 6 Bottom Barnstormer - @ Marquise - 143.5
142.4 153.9 93% 92-96% Pass
153.9 96% 92-96% Pass
7/10 5 Bottom Biplane - 85' E of Yeager -
95% 92-96% Pass
7/10 4 Bottom Biplane - 25' W of Maruise - 147.3
92-96% Pass
7/10 3 Bottom Coleman - 125' W of Marquise - 145.6 153.9
Pass
7/10 2 Bottom Marquise - 75' N of Supercub - 144.3 153.9 94%
7/10 1 Bottom Marquise - 75' N of Conquest - 145.3 153.9 94% 92-96%
(Pass/Fail)
Correction Gravity Required
Percent
Gauge Specific Compaction Compaction
Date Test # Lift Mix With Theoretical Percent
3 of 150
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 1 Application
Location Conquest 69' N of Sykes Mix Code A4520
Sidewalk
Placement Date 3/22/19 Supplier Martin Marietta
1732
Sample Time 11:09 AM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 49155515
Batch Time 10:17 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 143.0
Air Temperature @ Time of Placement - 47 °F
Concrete Temperature ASTM C-1064 90˚ Max 65 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
52760 Cone/Shear 4199
4390
57540 Cone/Shear 4579
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5093
5210
67050 Cone/Shear 5336
- - -
-
- - -
64000 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
3 of 20
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 2 Application
Location Conquest 100' N of Sykes Mix Code A4780
Sidewalk
Placement Date 3/26/19 Supplier Martin Marietta
210
Sample Time 1:00 PM Water Added On Site None
Placement Type Chute Ticket # 49155594
Batch Time 12:19 PM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.8
Air Temperature @ Time of Placement - 54 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
73350 Cone/Shear 5837
5750
71115 Cone/Shear 5659
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6297
6250
77870 Cone/Shear 6197
- - -
-
- - -
79125 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 88
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 3 Application
Location Block 5 Lot 5 Mix Code A4520
Sidewalk
Placement Date 3/27/19 Supplier Martin Marietta
1765
Sample Time 10:10 AM Water Added On Site None
Placement Type Chute Ticket # 49155678
Batch Time 9:33 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 55 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
57095 Cone/Shear 4543
4460
54960 Cone/Shear 4374
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5507
5570
70735 Cone/Shear 5629
- - -
-
- - -
69200 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 100
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 4 Application
Location Conquest - 80' W of Marquise Mix Code A4520
Sidewalk
Placement Date 3/28/19 Supplier Martin Marietta
1721
Sample Time 10:02 AM Water Added On Site 2 Gallons
Placement Type Chute Ticket # 49155781
Batch Time 9:17 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 141.6
Air Temperature @ Time of Placement - 50 °F
Concrete Temperature ASTM C-1064 90˚ Max 72 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60770 Cone/Shear 4836
4880
61815 Cone/Shear 4919
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5702
5670
70790 Cone/Shear 5633
- - -
-
- - -
71650 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 10
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 5 Application
Location Marquise & Conquest - SWC Mix Code A4780
Ramp
Placement Date 4/2/19 Supplier Martin Marietta
1729
Sample Time 9:00 AM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 49155964
Batch Time 8:31 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 142.4
Air Temperature @ Time of Placement - 42 °F
Concrete Temperature ASTM C-1064 90˚ Max 61 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
68540 Cone/Shear 5454
5510
69965 Cone/Shear 5568
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6796
6810
85870 Cone/Shear 6833
- - -
-
- - -
85405 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 11
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 6 Application
Location Marquise & Conquest - NWC Mix Code A4780
Ramp
Placement Date 4/2/19 Supplier Martin Marietta
1406
Sample Time 1:00 PM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 49155998
Batch Time 12:35 PM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 50 °F
Concrete Temperature ASTM C-1064 90˚ Max 60 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
65480 Cone/Shear 5211
5190
64970 Cone/Shear 5170
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6255
6310
80110 Cone/Shear 6375
- - -
-
- - -
78600 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 9
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 7 Application
Location Conquest & Zeppelin - SWC Mix Code A4780
Ramp
Placement Date 4/3/19 Supplier Martin Marietta
1905
Sample Time 9:00 AM Water Added On Site None
Placement Type Chute Ticket # 49156036
Batch Time 8:15 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 145.6
Air Temperature @ Time of Placement - 45 °F
Concrete Temperature ASTM C-1064 90˚ Max 60 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
58890 Cone/Shear 4686
4910
64545 Cone/Shear 5136
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6100
5890
71350 Cone/Shear 5678
- - -
-
- - -
76650 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 9
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 8 Application
Location Conquest & Zeppelin - NWC Mix Code A4780
Ramp
Placement Date 4/3/19 Supplier Martin Marietta
304
Sample Time 1:00 PM Water Added On Site None
Placement Type Chute Ticket # 49156058
Batch Time 12:32 PM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 58 °F
Concrete Temperature ASTM C-1064 90˚ Max 73 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60655 Cone/Shear 4827
4960
63995 Cone/Shear 5093
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6179
6170
77380 Cone/Shear 6158
- - -
-
- - -
77645 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 5
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 9 Application
Location Conquest - 120' W of Marquise Mix Code A4780
Ramp
Placement Date 4/4/19 Supplier Martin Marietta
1732
Sample Time 9:10 AM Water Added On Site None
Placement Type Chute Ticket # 49156087
Batch Time 8:15 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.5%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 51 °F
Concrete Temperature ASTM C-1064 90˚ Max 72 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
63320 Cone/Shear 5039
4830
58090 Cone/Shear 4623
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5967
5830
71635 Cone/Shear 5701
- - -
-
- - -
74980 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 11
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 10 Application
Location Conquest & Vicot - SE Corner Mix Code A4780
Ramp
Placement Date 4/8/19 Supplier Martin Marietta
1623
Sample Time 11:15 AM Water Added On Site None
Placement Type Chute Ticket # 49156262
Batch Time 10:43 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 143.2
Air Temperature @ Time of Placement - 71 °F
Concrete Temperature ASTM C-1064 90˚ Max 80 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
61105 Cone/Shear 4863
4840
60455 Cone/Shear 4811
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6221
6210
77925 Cone/Shear 6201
- - -
-
- - -
78180 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 15
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 11 Application
Location Sykes - 210' N of Conquest Mix Code A4520
Sidewalk
Placement Date 4/9/19 Supplier Martin Marietta
1729
Sample Time 9:33 AM Water Added On Site 3 Gallons
Placement Type Chute Ticket # 49156306
Batch Time 8:53 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 3"
Air Content (%) ASTM C-231 5.0% - 8.0% 60.0%
Unit Weight (pcf) Field - 144.8
Air Temperature @ Time of Placement - 58 °F
Concrete Temperature ASTM C-1064 90˚ Max 68 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
54915 Cone/Shear 4370
4460
57295 Cone/Shear 4559
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5728
5850
74960 Cone/Shear 5965
- - -
-
- - -
71980 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 11
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 12 Application
Location Manhole C11 Mix Code A4520
Manhole
Placement Date 4/9/19 Supplier Martin Marietta
1730
Sample Time 12:45 PM Water Added On Site 7 Gallons
Placement Type Chute Ticket # 49156325
Batch Time 11:56 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.5%
Unit Weight (pcf) Field - 143.2
Air Temperature @ Time of Placement - 71 °F
Concrete Temperature ASTM C-1064 90˚ Max 77 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
54595 Cone/Shear 4345
4230
51740 Cone/Shear 4117
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5604
5510
68110 Cone/Shear 5420
- - -
-
- - -
70420 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
- of -
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 13 Application
Location C7-2 Mix Code A4780
Inlet
Placement Date 4/12/19 Supplier Martin Marietta
743
Sample Time 2:55 PM Water Added On Site None
Placement Type Chute Ticket # 49156395
Batch Time 2:17 PM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 145.6
Air Temperature @ Time of Placement - 36 °F
Concrete Temperature ASTM C-1064 90˚ Max 61 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
75105 Cone/Shear 5977
5870
72335 Cone/Shear 5756
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
7508
7500
94230 Cone/Shear 7499
- - -
-
- - -
94350 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 13
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 14 Application
Location MH D1 Mix Code A4520
Manhole
Placement Date 4/15/19 Supplier Martin Marietta
1729
Sample Time 8:45 AM Water Added On Site None
Placement Type Chute Ticket # 49156409
Batch Time 7:56 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.5%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 55 °F
Concrete Temperature ASTM C-1064 90˚ Max 65 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60975 Cone/Shear 4852
4790
59335 Cone/Shear 4722
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5986
5670
67195 Cone/Shear 5347
- - -
-
- - -
75220 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 10
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 15 Application
Location Conquest St - 60' E of Conquest Way Mix Code A4780
Sidewalk
Placement Date 4/16/19 Supplier Martin Marietta
1624
Sample Time 9:15 AM Water Added On Site None
Placement Type Chute Ticket # 75005120
Batch Time 8:12 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.8
Air Temperature @ Time of Placement - 54 °F
Concrete Temperature ASTM C-1064 90˚ Max 65 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
59275 Cone/Shear 4717
4830
62115 Cone/Shear 4943
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5834
5770
71700 Cone/Shear 5706
- - -
-
- - -
73315 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 7
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 16 Application
Location Sykes - 20' N of Conquest Mix Code A4780
Sidewalk
Placement Date 4/16/19 Supplier Martin Marietta
628
Sample Time 1:05 PM Water Added On Site None
Placement Type Chute Ticket # 49156510
Batch Time 12:25 PM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.0%
Unit Weight (pcf) Field - 143.2
Air Temperature @ Time of Placement - 62 °F
Concrete Temperature ASTM C-1064 90˚ Max 72 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
63165 Cone/Shear 5027
4980
62120 Cone/Shear 4943
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6050
5960
73840 Cone/Shear 5876
- - -
-
- - -
76030 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 8
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 17 Application
Location Conquest - 17' E o Vicot Mix Code A4780
Sidewalk
Placement Date 4/17/19 Supplier Martin Marietta
1917
Sample Time 9:25 AM Water Added On Site None
Placement Type Chute Ticket # 49156554
Batch Time 8:29 AM Truck #
Sampled At (yards) Field Personnel GR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.8
Air Temperature @ Time of Placement - 53 °F
Concrete Temperature ASTM C-1064 90˚ Max 64 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
61705 Cone/Shear 4910
4910
61610 Cone/Shear 4903
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5625
5690
72445 Cone/Shear 5765
- - -
-
- - -
70680 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 5
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 18 Application
Location D3 Mix Code A4780
Inlet Base
Placement Date 4/20/19 Supplier Martin Marietta
1623
Sample Time 11:30 AM Water Added On Site 4 Gallons
Placement Type Chute Ticket # 49156790
Batch Time 10:57 AM Truck #
Sampled At (yards) Field Personnel KR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.9%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 64 °F
Concrete Temperature ASTM C-1064 90˚ Max 60 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
59690 Cone/Shear 4750
4680
57860 Cone/Shear 4604
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
4727
5280
73275 Cone/Shear 5831
- - -
-
- - -
59400 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 5
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 19 Application
Location D3 Mix Code A4780
Inlet Walls
Placement Date 4/22/19 Supplier Martin Marietta
630
Sample Time 2:25 PM Water Added On Site 4 Gallons
Placement Type Chute Ticket # 49156818
Batch Time 1:47 PM Truck #
Sampled At (yards) Field Personnel KR
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.0
Air Temperature @ Time of Placement - 46 °F
Concrete Temperature ASTM C-1064 90˚ Max 61 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
67115 Cone/Shear 5341
5380
68150 Cone/Shear 5423
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6302
6360
80695 Cone/Shear 6422
- - -
-
- - -
79195 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
3 of 10
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 20 Application
Location D6 Mix Code A4780
Inlet Walls
Placement Date 4/24/19 Supplier Martin Marietta
1917
Sample Time 3:41 PM Water Added On Site 10 Gallons
Placement Type Chute Ticket # 49156947
Batch Time 3:14 PM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 141.6
Air Temperature @ Time of Placement - 73 °F
Concrete Temperature ASTM C-1064 90˚ Max 74 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
61985 Cone/Shear 4933
4910
61480 Cone/Shear 4892
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6153
6290
80740 Cone/Shear 6425
- - -
-
- - -
77315 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 10
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 21 Application
Location SE Cor Zeppelin & Alley A Mix Code A4780
Sidewalk
Placement Date 4/25/19 Supplier Martin Marietta
1721
Sample Time 1:15 PM Water Added On Site None
Placement Type Chute Ticket # 49157017
Batch Time 12:36 PM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 144.4
Air Temperature @ Time of Placement - 75 °F
Concrete Temperature ASTM C-1064 90˚ Max 72 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
59755 Cone/Shear 4755
5000
66030 Cone/Shear 5255
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6299
6450
82980 Cone/Shear 6603
- - -
-
- - -
79160 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 8
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 22 Application
Location SE Cor Vicot & Alley A Mix Code A4780
Sidewalk
Placement Date 4/26/19 Supplier Martin Marietta
1721
Sample Time 9:05 AM Water Added On Site None
Placement Type Chute Ticket # 49157063
Batch Time 8:26 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.0%
Unit Weight (pcf) Field - 145.6
Air Temperature @ Time of Placement - 70 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60100 Cone/Shear 4783
4760
59580 Cone/Shear 4741
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6195
6250
79350 Cone/Shear 6314
- - -
-
- - -
77850 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 7
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 23 Application
Location NE Cor Sykes & Conquest Mix Code A4780
Sidewalk
Placement Date 5/2/19 Supplier Martin Marietta
509
Sample Time 1:00 PM Water Added On Site None
Placement Type Chute Ticket # 49157253
Batch Time 12:27 PM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.2%
Unit Weight (pcf) Field - 145.4
Air Temperature @ Time of Placement - 70 °F
Concrete Temperature ASTM C-1064 90˚ Max 66 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
62140 Cone/Shear 4945
4780
57935 Cone/Shear 4610
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6285
6210
77045 Cone/Shear 6131
- - -
-
- - -
78985 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 4
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 24 Application
Location Conquest - 27' W of Navion Mix Code A4780
Ramp
Placement Date 5/3/19 Supplier Martin Marietta
225
Sample Time 9:02 AM Water Added On Site None
Placement Type Chute Ticket # 49157296
Batch Time 8:37 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.2%
Unit Weight (pcf) Field - 145.4
Air Temperature @ Time of Placement - 64 °F
Concrete Temperature ASTM C-1064 90˚ Max 67 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
59590 Cone/Shear 4742
4700
58455 Cone/Shear 4652
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5905
5890
73770 Cone/Shear 5870
- - -
-
- - -
74205 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 9
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 25 Application
Location Conquest & Alley A Mix Code A4780
Sidewalk/Curb & Gutter
Placement Date 5/4/19 Supplier Martin Marietta
1721
Sample Time 9:42 AM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 75006300
Batch Time 8:40 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 3 3/4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.5%
Unit Weight (pcf) Field - 145.6
Air Temperature @ Time of Placement - 54 °F
Concrete Temperature ASTM C-1064 90˚ Max 69 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
49635 Cone/Shear 3950
4080
52895 Cone/Shear 4209
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5612
5680
72280 Cone/Shear 5752
- - -
-
- - -
70525 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 7
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 26 Application
Location 402 Tigercat Way Mix Code A4780
Sidewalk
Placement Date 5/6/19 Supplier Martin Marietta
1732
Sample Time 11:00 AM Water Added On Site None
Placement Type Chute Ticket # 49157418
Batch Time 10:17 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.3%
Unit Weight (pcf) Field - 144.4
Air Temperature @ Time of Placement - 61 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
55325 Cone/Shear 4403
4310
52940 Cone/Shear 4213
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5771
5820
73650 Cone/Shear 5861
- - -
-
- - -
72525 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
2 of 11
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 27 Application
Location Conquest & Vicot - NW Corner Mix Code A4780
Ramp
Placement Date 6/4/19 Supplier Martin Marietta
2012
Sample Time 1:28 PM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 49158573
Batch Time 1:07 PM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0% 5.3%
Unit Weight (pcf) Field - 145.4
Air Temperature @ Time of Placement - 82 °F
Concrete Temperature ASTM C-1064 90˚ Max 84 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60475 Cone/Shear 4812
4780
59610 Cone/Shear 4744
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
6512
6600
83970 Cone/Shear 6682
- - -
-
- - -
81835 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
1 of 150
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
General
Set # 28 Application
Location Conquest - 30' E of Marquise Mix Code A4520
Curb & Gutter
Placement Date 6/10/19 Supplier Martin Marietta
1732
Sample Time 9:00 AM Water Added On Site 7 Gallons
Placement Type Chute Ticket # 49159923
Batch Time 8:26 AM Truck #
Sampled At (yards) Field Personnel LK
Project Specifications and Test Results
Test Specifications Results
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0% 6.7%
Unit Weight (pcf) Field - 145.6
Air Temperature @ Time of Placement - 63 °F
Concrete Temperature ASTM C-1064 90˚ Max 64 °F
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
-
60955 Cone/Shear 4851
4630
55420 Cone/Shear 4410
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
5402
5480
69745 Cone/Shear 5550
- - -
-
- - -
67885 Cone/Shear
-
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
75 of 150
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5301
5440
70210 Cone/Shear 5587
- - -
-
- - -
66615 Cone/Shear
-
53940 Cone/Shear 4292
4330
54995 Cone/Shear 4376
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 69 °F
Concrete Temperature ASTM C-1064 90˚ Max 68 °F
6.4%
Unit Weight (pcf) Field - 143.2
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel KR
1729
Sample Time 11:50 AM Water Added On Site 7 Gallons
Placement Type Chute Ticket # 49158944
Batch Time 11:17 AM Truck #
Location Yaeger - 75' E of Coleman Mix Code A4520
Curb & Gutter
Placement Date 6/10/19 Supplier Martin Marietta
General
Set # 29 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
3 of 200
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5455
5470
68910 Cone/Shear 5484
- - -
-
- - -
68545 Cone/Shear
-
53955 Cone/Shear 4294
4240
52650 Cone/Shear 4190
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 59 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
6.5%
Unit Weight (pcf) Field - 144.0
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel KR
304
Sample Time 7:10 AM Water Added On Site None
Placement Type Chute Ticket # 49158986
Batch Time 6:24 AM Truck #
Location Coleman - 75' W of Marquise Mix Code A4520
Curb & Gutter
Placement Date 6/11/19 Supplier Martin Marietta
General
Set # 30 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
102 of 200
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5040
5070
64105 Cone/Shear 5101
- - -
-
- - -
63340 Cone/Shear
-
49000 Cone/Shear 3899
3850
47765 Cone/Shear 3801
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 75 °F
Concrete Temperature ASTM C-1064 90˚ Max 70 °F
6.9%
Unit Weight (pcf) Field - 144.0
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel KR
8661
Sample Time 11:40 AM Water Added On Site None
Placement Type Chute Ticket # 49159034
Batch Time 10:55 AM Truck #
Location Barnstormer - 40' W of Yeager Mix Code A4520
Curb & Gutter
Placement Date 6/11/19 Supplier Martin Marietta
General
Set # 31 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
3 of 150
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6152
6280
80560 Cone/Shear 6411
- - -
-
- - -
77305 Cone/Shear
-
66285 Cone/Shear 5275
5150
63090 Cone/Shear 5021
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 53 °F
Concrete Temperature ASTM C-1064 90˚ Max 80 °F
6.1%
Unit Weight (pcf) Field - 144.4
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel KR
1765
Sample Time 7:20 AM Water Added On Site None
Placement Type Chute Ticket # 49159208
Batch Time 6:29 AM Truck #
Location Vicoty Way - 100' N of Conquest Mix Code A4520
Curb & Gutter
Placement Date 6/13/19 Supplier Martin Marietta
General
Set # 32 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
83 of 150
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6028
6050
76300 Cone/Shear 6072
- - -
-
- - -
75750 Cone/Shear
-
58385 Cone/Shear 4646
4470
53945 Cone/Shear 4293
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 78 °F
Concrete Temperature ASTM C-1064 90˚ Max 80 °F
6.2%
Unit Weight (pcf) Field - 144.2
Slump (in) ASTM C-143 2" - 4" 2"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel KR
1765
Sample Time 11:15 AM Water Added On Site None
Placement Type Chute Ticket # 4915936
Batch Time 10:46 AM Truck #
Location Barnstormer - 100' W of Maruise Mix Code A4520
Curb & Gutter
Placement Date 6/13/19 Supplier Martin Marietta
General
Set # 33 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
1 of 5
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6090
6290
81490 Cone/Shear 6485
- - -
-
- - -
76525 Cone/Shear
-
58240 Cone/Shear 4635
4620
57835 Cone/Shear 4602
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 70 °F
Concrete Temperature ASTM C-1064 90˚ Max 78 °F
6.0%
Unit Weight (pcf) Field - 146.4
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel GR
304
Sample Time 12:05 PM Water Added On Site None
Placement Type Chute Ticket # 49159409
Batch Time 11:24 AM Truck #
Location Vicoty - 15' N of Conquest Mix Code A4780
Curb & Gutter Tie-In
Placement Date 6/17/19 Supplier Martin Marietta
General
Set # 34 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
2 of 12
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6523
6640
84845 Cone/Shear 6752
- - -
-
- - -
81965 Cone/Shear
-
61535 Cone/Shear 4897
4890
61430 Cone/Shear 4888
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 80 °F
Concrete Temperature ASTM C-1064 90˚ Max 85 °F
5.5%
Unit Weight (pcf) Field - 145.7
Slump (in) ASTM C-143 2" - 4" 3"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1716
Sample Time 1:03 PM Water Added On Site 4 Gallons
Placement Type Chute Ticket # 49159645
Batch Time 12:32 PM Truck #
Location SE Cor of Barnstormer & Vicot Mix Code A4780
Curb & Gutter
Placement Date 6/20/19 Supplier Martin Marietta
General
Set # 35 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
2 of 10
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5868
5900
74630 Cone/Shear 5939
- - -
-
- - -
73745 Cone/Shear
-
58040 Cone/Shear 4619
4550
56345 Cone/Shear 4484
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 68 °F
Concrete Temperature ASTM C-1064 90˚ Max 00 °F
5.5%
Unit Weight (pcf) Field - 145.0
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1735
Sample Time 9:20 AM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 75009565
Batch Time 8:14 AM Truck #
Location Navion - 45' N of Conquest Mix Code A4780
Curb & Gutter
Placement Date 6/25/19 Supplier Martin Marietta
General
Set # 36 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
2 of 6
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6583
6560
82120 Cone/Shear 6535
- - -
-
- - -
82720 Cone/Shear
-
67425 Cone/Shear 5366
5350
66920 Cone/Shear 5325
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 65 °F
Concrete Temperature ASTM C-1064 90˚ Max 80 °F
5.0%
Unit Weight (pcf) Field - 141.7
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
743
Sample Time 9:11 AM Water Added On Site 4 Gallons
Placement Type Chute Ticket # 49159789
Batch Time 8:35 AM Truck #
Location @ Coleman & Marquise Mix Code A4780
Curb & Gutter
Placement Date 6/26/19 Supplier Martin Marietta
General
Set # 37 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
3 of 15
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5343
5540
71990 Cone/Shear 5729
- - -
-
- - -
67145 Cone/Shear
-
50840 Cone/Shear 4046
4190
54375 Cone/Shear 4327
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 73 °F
Concrete Temperature ASTM C-1064 90˚ Max 89 °F
5.5%
Unit Weight (pcf) Field - 143.6
Slump (in) ASTM C-143 2" - 4" 5"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1737
Sample Time 1:35 PM Water Added On Site 5 Gallons
Placement Type Chute Ticket # 75009808
Batch Time 12:36 PM Truck #
Location @ Supercub & Marquise Mix Code A4780
Gutter Cross Pan
Placement Date 6/26/19 Supplier Martin Marietta
General
Set # 38 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
3 of 15
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5460
5360
66075 Cone/Shear 5258
- - -
-
- - -
68615 Cone/Shear
-
55330 Cone/Shear 4403
4410
55460 Cone/Shear 4413
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 63 °F
Concrete Temperature ASTM C-1064 90˚ Max 80 °F
6.0%
Unit Weight (pcf) Field - 143.6
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1707
Sample Time 9:15 AM Water Added On Site None
Placement Type Chute Ticket # 75009931
Batch Time 8:23 AM Truck #
Location @ Coleman & Marquise Mix Code A4780
Gutter Cross Pan
Placement Date 6/27/19 Supplier Martin Marietta
General
Set # 39 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
3 of 15
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
6379
6560
84780 Cone/Shear 6747
- - -
-
- - -
80160 Cone/Shear
-
61240 Cone/Shear 4873
4870
61100 Cone/Shear 4862
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 73 °F
Concrete Temperature ASTM C-1064 90˚ Max 85 °F
6.0%
Unit Weight (pcf) Field - 144.2
Slump (in) ASTM C-143 2" - 4" 3"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1750
Sample Time 1:30 PM Water Added On Site None
Placement Type Chute Ticket # 75010005
Batch Time 12:30 PM Truck #
Location @ Biplane & Marquise Mix Code A4780
Gutter Cross Pan
Placement Date 6/27/19 Supplier Martin Marietta
General
Set # 40 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
24 of 50
Age
Specimen (days)
1.3a 3
1.3b 3
1.7a 7
1.7b 7
1.14a 14
1.14b 14
1.28a 28
1.28b 28
1.56a 56
1.56b 56 -
Specimen Diameter = 4 in Specimen Cross-Sectional Area = 12.57 sq in
- - -
-
- -
5372
5370
67490 Cone/Shear 5371
- - -
-
- - -
67505 Cone/Shear
-
53270 Cone/Shear 4239
4250
53660 Cone/Shear 4270
Load (lbs) Failure Type (psi) (psi)
- - -
-
- -
Compressive Strength Test Results (ASTM C-39/C-31)
Maximum Applied Compressive Strength Rounded Avg.
28-day Compressive Strength (min) 4000 psi See Below
Air Temperature @ Time of Placement - 71 °F
Concrete Temperature ASTM C-1064 90˚ Max 82 °F
5.9%
Unit Weight (pcf) Field - 144.2
Slump (in) ASTM C-143 2" - 4" 4"
Air Content (%) ASTM C-231 5.0% - 8.0%
Project Specifications and Test Results
Test Specifications Results
Sampled At (yards) Field Personnel LK
1601
Sample Time 9:33 AM Water Added On Site None
Placement Type Chute Ticket # 49159925
Batch Time 8:48 AM Truck #
Location @ Biplane & Yeager Mix Code A4780
Gutter Cross Pan
Placement Date 6/29/19 Supplier Martin Marietta
General
Set # 41 Application
16-2046
Summary of Cast-In-Place Concrete Test
EAST RIDGE PHASE 6
Fort Collins, Colorado
Approximate Test Location
Density
Fort Collins, Colorado
Project # 16-2046
July 2019
Field Asphaltic Concrete Density Test Summary
EAST RIDGE