HomeMy WebLinkAboutLAKEVIEW ON THE RISE - Filed CSS-COMPRESSIVE STRENGTH SUMMARY - 2019-08-30Report Number: Service Date: Report Date: Task: Client Fort Collins, CO 6740 South College Avenue Signature Construction LLC Lakeview on the Rise Apartment Development Attn: Matt Boyle 720 3rd Ave SW Carmel, IN 46032-2036 970-484-0359 Fort Collins, CO 80525-4429 1901 Sharp Point Dr, Ste C Concrete 20181040.0265 07/31/19 08/28/19 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 20181040 Specified Strength: 28 days Mix ID: Supplier: Batch Time: Truck No.: A4305 Martin Marietta Materials Material Information 1340 1716 Plant: Ticket No.: 49161549 Field Test Data Test Air Content (%): Result Specification 4 3-5 4.5 4.5-7.5 88 95 145.3 4,500 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: 07/31/19 Sample Time: 1600 Douglas Novosad Sunny 40/40 10 Sample Location: East end of crosspan for Lorien lane Placement Method: Direct Discharge Water Added Before (gal): Report Date: Service Date: Report Number: Task: 20181040.0265 07/31/19 08/28/19 1901 Sharp Point Dr, Ste C Fort Collins, CO 80525-4429 Concrete 970-484-0359 Revision 1 - 28-day results Distribution List Distribution Page (1) Signature Construction LLC, Matt Boyle (1) Connell Resources Inc, Jeff Laugel (1) Martin Marietta Materials Inc, Bill Meek (1) Martin Marietta Materials Inc, Matt Hysen (1) Signature Construction LLC, Taylor Elizalde (1) Signature Construction LLC, Trevor Rine (1) Terracon Consultants, Inc., Eric Bernhardt (1) Total Concrete Services Inc, Jeff Cast (1) Total Concrete Services Inc, John Montanez Water Added After (gal): Accumulative Yards: Batch Size (cy): Crosspans from intersections for Debra Dr and Baggins Dr and Lorien Lane to Parking between Buildings 14 and 13. Placement Location: Laboratory Test Data Set Avg Diam. Area Date Weight Date Test Age at Load Maximum Strength Compressive Fracture No. ID Specimen (in) (sq in) Received Tested (days) (lbs) (psi) Type Tested (lbs) By 23 1 4.00 12.57 8.60 08/07/19 7 51,240 4,080 3 BA 23 2 4.00 12.57 8.68 08/28/19 28 66,790 5,310 3 23 3 4.00 12.57 8.68 08/28/19 28 67,060 5,340 3 23 4 4.00 12.57 8.60 08/28/19 28 66,460 5,290 3 Average (28 days) 5,310 Initial Cure: Outside Final Cure: Moist Room Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Concrete was scheduled for 4:00pm and when terracon tester showed up at 3:50, they were already getting ready to place the last truck. Crosspan for Debra Dr and Baggins Dr had already been completed before tester was present and test ran. Terracon informed JC with TCS that the concrete hold time for the batach was approximately 2 hours and 40 minutes. Samples Made By: Terracon Services: Reported To: Contractor: Report Distribution: See attached distribution list. Craig L. Nelson Project Manager Connell JC w/ TCS Concrete and Wayne w/ City of Fort Collins Reviewed By: Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064 Terracon Rep.: Douglas Novosad The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0001, 11-16-12, Rev.6 Page 1 of 1