Loading...
HomeMy WebLinkAboutCOLORADO IRON AND METAL - Filed FDT-FIELD DENSITY TEST - 2017-12-134396 GREENFIELD DRIVE WINDSOR, COLORADO 80550 (970) 545-3908 FAX (970) 663-0282 www.earth-engineering.com November 20, 2017 Giuliano & Father Construction, Inc. 308 Commerce Drive Fort Collins, Colorado 80524 Attn: Mr. John Giuliano (john@giulianoco.com) Re: Construction Observation and Testing – Submittal No. 1 903 Buckingham Street – Pavement Improvements Fort Collins, Colorado EEC Project No. 1174111 Mr. Giuliano: As requested, during the period of October 23 through November 4, 2017, Earth Engineering Consultants, LLC (EEC) personnel provided construction observation and testing services for the on-going construction improvements associated with the 903 Buckingham Street pavement improvements project in Fort Collins, Colorado. The services provided during the referenced period were on a part-time/on-call basis and included observations, field density testing of road subgrade materials at locations as described herein for the referenced project. The results of the observation and testing services completed by EEC personnel during the referenced period are included with this report. Field Density Testing Services During the referenced period, EEC personnel performed field density tests on road subgrade materials that had been prepared/placed and compacted prior to and/or during our various site visits. The field density tests were completed at random locations within the areas tested, and were performed in general accordance with ASTM Specification D6938. The field density test results and approximate locations of each test completed during the referenced period are shown on the attached summary sheet. The field density test results conformed to typical project specific compaction requirements of at least 95% of standard Proctor maximum dry density (ASTM D698), and were generally within ±2% of optimum moisture content. Proctor Designation Base Maximum Dry Density (pcf) 135.5 Optimum Moisture Content (%) 7.5% Required Moisture Variance OMC +/-2% Required Percent Compaction 95% Laboratory Method ASTM D-698 Compliance with Project Specs Elev. / Lift No. Material (Proctor) Percent Moisture Dry Density Moisture (Pass / Fail) %Comp. (Pass / Fail) 1 11/4 1 Road Subgrade in Easement FSG Base 5.9% 132.3 -1.6% 98% Pass Pass 2 11/4 2 Road Subgrade in Easement FSG Base 6.3% 132.6 -1.2% 98% Pass Pass 3 11/4 3 Road Subgrade in Easement FSG Base 6.4% 131.9 -1.1% 97% Pass Pass EARTH ENGINEERING CONSULTANTS, LLC Approximate Test Location / Notes Daily Test Number Date Consecutive Test Number Moisture Variance Percent Compaction Field Test Results Project Name: 903 Buckingham SUMMARY OF FIELD DENSITY TESTS Location: Fort Collins, Colorado Project No: Date: 1174111 November 2017