Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of
the above referenced project. If you have questions about any comments, you may contact the individual commenter or
direct your questions through the Project Planner, Rebecca Everette, at 970-416-2625 or reverette@fcgov.com.
Comment Summary:
Department: Planning Services
Contact: Rebecca Everette, 970 416-2625, revens1190001com
Topic: General
Comment Number: 8
Comment Originated: 08/05/2015
08/05/2015: Much of the previous conversation on this project centered around activating the
comer at Illinois Drive and Limon Drive. However, the current development plan does not activate
that comer, and defers public improvements and development there to a later project. I am
concerned that development at that comer is not predictable with this plan and may not fully
integrate (in the future) with the project that is currently proposed. Lets discuss options for ensuring
that the ultimate development of the western lot is consistent with the plans shown here. If the
western parcel is ultimately included in the development plan, as discussed at the staff review
meeting, that would help to address my concerns.
Response — Pedestrian improvements have been included in the first phase construction of the
project. The comer of Illinois and Limon are proposed to be activated through the use of enhanced
pedestrian plaza areas that lead to the larger plaza areas associated with the building.
Topic: Landscape Plans
Comment Number: 3
Comment Originated: 08/04/2015
08/04/2015: Section 3.2.1(D)(1)(c) of the LUC requires "full tree stocking"
along all high use or high visibility sides of a building. This standard appears to
be met on the south and east sides of the building, but there are not enough
sewer have capacity.
Response — We have modelled the new total flow to the Iowa inlet with the HGL from the original report to
verify it will not flood the immediate downstream pipe.
Comment Number: 3 Comment Originated: 08/04/2015
08/04/2015: Please provide the LID table to verify the site is meeting the LID
requirements. This detail can be electronically delivered upon request.
Response —Added.
Comment Number: 4 Comment Originated: 08/04/2015
08/04/2015: The porous paver detail is not per City Standards. Please provide
a detail that is consistent with the City's porous paver schematic.
Response — Revised.
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty0fcgov.com
Topic: Building Elevations
Comment Number: 1
08/04/20.15: No comments.
Comment Originated: 08/04/2015
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 08/04/2015
08/04/2015: Please change the title to "Lot 2, Warren Federal Credit Union -
East Drake".
Response — Revised — this is now Lot 3 and Tract A for the PDP.
Comment Number: 3 Comment Originated: 08/04/2015
08/04/2015: Please provide the following information for the Benchmark
Statement in the EXACT format shown below.
PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # w/ DESCRIPTION
ELEVATION:
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE,
THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED
= NAVD88 - X.XXL.
Response — Revised
Comment Number: 4
Comment Originated: 08/04/2015
10
. e -
08/04/2015: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
Response— Revised
Comment Number: 5 Comment Originated: 08/04/2015
08/04/2015: There are line over text issues. See redlines.
Response — Revised
Comment Number: 6 Comment Originated: 08/04/2015
08/04/2015: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
Response — Revised.
Topic: Landscape Plans
Comment Number: 7 Comment Originated: 08/04/2015
08/04/2015: The lighter background text & linework marked is not acceptable. It
will not scan or reproduce. Please darken it up. See redlines.
Response — Linework screening has been corrected
Topic: Lighting Plan
Comment Number: 8
08/04/2015: No comments.
Comment Originated: 08/04/2015
Topic: Plat
Comment Number: 9 Comment Originated: 08/04/2015
08/04/2015: Please change the titleblock to match the title. See redlines.
Response — Revised.
Topic: Site Plan
Comment Number: 10 Comment Originated: 08/04/2015
08/04/2015: Please change the legal description to "Lot 2, Warren Federal
Credit Union - East Drake".
Response — Revised
Comment Number: 11 Comment Originated: 08/04/2015
08/04/2015: There is text that needs to be rotated 180 degrees. See redlines.
Response — Revised
Comment Number: 12 Comment Originated: 08/04/2015
08/04/2015: The lighter background text & linework marked is not acceptable. It
will not scan or reproduce. Please darken it up. See redlines.
Response — Revised
Department: Traffic Operation
Contact: Martina Wilkinson, 970-221-6887, mwilkinso i ft9ov.com
Topic: General
Comment Number: 1
Comment Originated: 08/04/2015
11
08/04/2015: Since access spacing, sidewalk width etc along Illinios is a
concern, it would be helpful on the plans to more clearly indicate that the Lot 1 is
not a part of this submittal (perhaps shaded back more..)
Response — This future drive has been removed from the plan altogether.
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson(occgov.com
Topic: General
Comment Number: 1 Comment Originated: 08/04/2015
08/04/2015: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson(@fcgov.com
Response — Acknowledged
Department: Water -Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wiamarguefficgov.com
Topic: General
Comment Number: 1 Comment Originated: 08/04/2015
08/04/2015: Please add all water and sewer details during final compliance.
Response — Acknowledged
Department: Zoning
Contact: Gary Lopez, 970-416-2338, gloaez(afcgov.com
Topic: Site Plan
Comment Number:
Comment Originated: 07/24/2015
07/24/2015: 1 believe the build to lines for streetfront buildings (LUC 3.5.3[C][21)
would require the building be moved towards the NE corner of the property near
the intersection.
Response — Revised
Please include the following comment(s) from GIS:
Comment Number:1
Addresses will be assigned by the GIS Department after the plans have met final
approval through Development Review and are recorded with the City.
Comment Number: 2
Projects with three or more tenant units require the Unit Level Addressing form to be completed and
submitted to the GIS Department once plans have met final approval through Development Review and are
recorded with the City. This can occur anytime during construction, but before any utilities or address signs
are installed. All addressing will be determined by the GIS Department and submitted to Poudre Fire
Authority, USPS, Building Services, and Fort Collins Utilities. Failure to contact GIS and determining
addresses through other means may result in address changes.
The Unit Level Addressing form can be obtained by contacting the GIS office at gisafcgov.com or (970)
416-2483.
12
Marc Ragasa
From: Mike Oberlander <moberlander@interwestgrp.com>
Sent: Wednesday, December 09, 2015 4:48 PM
To: Marc Ragasa
Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider
Subject: WFCU Additional Information
Attachments: WFCU WALK GRADING.pdf; ILLINOIS SECTION.pdf; Seven Generations Drive - No
Variance.pdf; WFCU 5 Degree Entry Drive.pdf
Marc -
Wanted to respond to a couple of your comments and see if we can satisfy you so we can get to a hearing.
Curb Ramps:
We talked after the meeting and we think it will be OK to have the ramps standard at the corners and not have pots,
colors, or anything in the ROW. You have a comment to match the ramps on the opposite sides of the street — based on
what I can see on an aerial and on PDP plans for the development to the south, I think we are — we are matching the
curb drops that were built when the street was built. The attached grading plan shows the ramps.
Section for Illinois:
The section we want is the one that was approved when Illinois was built — cover sheet of those plans are attached and
the section is on the bottom of the sheet. We can do the 5' tree grates and the "walk" area will still be 6' to ROW (it is a
12' dim from FL of curb to ROW). Except at the 2 inlets, I plan to have this entire walk at 2%. 1 think the issue at Subway
is that there is no utility easement, so that is a zero lot line setup. On our property we have the 9' UE, so the buildings
will be back from the walk and grades can be adjusted outside of the ROW. The grading plan shows what I want to do
here.
Drive entry:
I attached my old plans for the Seven Generations Driveway — I looked at the notes sheet and we did not get a variance
for this. I also have attached a drawing showing if we revise the drive to a tangent section that intersects the street at 5
degrees. This is shown in red and meets standards without any variance. I think on 7 Gens, I argued that the little curve
looked better that the skewed tangent and Sheri and Susan said good enough. If we can leave the curve without a
variance, I would like to do that, if we need to prepare, submit and pay for a variance, we will change to the red, tangent
line.
I think if we can agree on these 3 points, it sounds like you will be good for hearing. Please let us know.
Thanks.
Mike
Michael Oberlander, PE, LEED AP
Interwest Consulting Group
DIRECT — 970-460-8471
C — 970.631.2671
m
Marc Ragasa
From: Mike Oberlander <moberlander@interwestgrp.com>
Sent: Friday, December 11, 2015 7:50 AM
To: Marc Ragasa
Cc: 'Michael McBride';'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider
Subject: RE: WFCU Additional Information
The overall dimension from face of curb to back of walk is 12'. 1 will work with BHA, but we think the 5' tree grate will
start 12" behind face of curb so we can build the concrete to hold the frames and not take out any existing curb). That
would leave 6'-0" clear behind the grate. That may change to 5'-6", but I don't think so.
We will detail on the final plans.
Thanks for working with me quickly on this.
Mike
Michael Oberlander, PE, LEED AP
Interwest Consulting Group
DIRECT — 970-460-8471
C — 970.631.2671
From: Marc Ragasa [mailto:mragasaCalfcgov.com]
Sent: Thursday, December 10, 2015 3:24 PM
To: Mike Oberlander
Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider
Subject: RE: WFCU Additional Information
Mike,
I'm not quite sure what the cross section of Illinois Drive would look like. Are we going to have curb, 1' behind curb, 5'
tree grate and a 5'-6" walk (11'-6" with 6" curb) as opposed to 6'-6" curb? Let's just make sure we depict this cross
section on final plans that depict the larger tree grates.
Engineering would support the driveway as proposed, without the need of a variance.
Tha nk you,
Marc Ragasa
City of Fort Collins
Engineering Department
970-221-6603
mragasaCaD-fcaov.com
From: Mike Oberlander [mailto:moberlanderC&interwestgrp.com]
Sent: Wednesday, December 09, 2015 4:48 PM
To: Marc Ragasa
Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider
Subject: WFCU Additional Information
Marc -
Wanted to respond to a couple of your comments and see if we can satisfy you so we can get to a hearing.
Curb Ramps:
We talked after the meeting and we think it will be OK to have the ramps standard at the corners and not have pots,
colors, or anything in the ROW. You have a comment to match the ramps on the opposite sides of the street — based on
what I can see on an aerial and on PDP plans for the development to the south, I think we are — we are matching the
curb drops that were built when the street was built. The attached grading plan shows the ramps.
Section for Illinois:
The section we want is the one that was approved when Illinois was built — cover sheet of those plans are attached and
the section is on the bottom of the sheet. We can do the 5' tree grates and the "walk" area will still be 6' to ROW (it is a
12' dim from FL of curb to ROW).` Except at the 2 inlets, I plan to have this entke walk at 2%. 1 think the issue at Subway
is that there is no utility easement, so that is a zero lot line setup. On our property we have the 9' UE, so the buildings
will be back from the walk and grades can be adjusted outside of the ROW. The grading plan shows what I want to do
here.
Drive entry:
I attached my old plans for the Seven Generations Driveway — I looked at the notes sheet and we did not get a variance
for this. I also have attached a drawing showing if we revise the drive to a tangent section that intersects the street at 5
degrees. This is shown in red and meets standards without any variance. I think on 7 Gens, I argued that the little curve
looked better that the skewed tangent and Sheri and Susan said good enough. If we can leave the curve without a
variance, I would like to do that, if we need to prepare, submit and pay for a variance, we will change to the red, tangent
line.
I think if we can agree on these 3 points, it sounds like you will be good for hearing. Please let us know.
Thanks.
Mike
Michael Oberlander, PE, LEED AP
Interwest Consulting Group
DIRECT— 970-460-8471
C — 970.631.2671
atypf
o t Cottins
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
kgov.cw Vdeve1opmentrevfew
December 14, 2015 .
Jerod Huwa
BHA Design, Inc.
1603 Oakridge Dr.
Fort Collins, CO 80525
RE: Warren Federal Credit Union, PDP150011, Round Number 2
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Project Planner, Jason Holland, at 970-224-6126orjholland@fcgov.com.
Comment Summary:
Department: Planning Services
Contact: Jason Holland, 970-224-6126, jholland gov.com
Topic: General
Comment Number: 9 Comment Originated: 12/09/2015
12/09/2015: Please see redline plans for detailed comments.
Response — Revised per redlines
Comment Number: 10 Comment Originated: 12/09/2015
12/09/2015: Tree grates along the Illinois Drvie must be 5' if feasible. Also
perimeter evergreen material must be incorporated into parking lot screening.
Response - The tree grates have been resized to 5'x5' and evergreen plant material was added to the
parking lot screening.
Comment Number: 11
Comment Originated: 12/09/2015
12109/2015: Need more landscape transition depth along Limon Drive.
Wall/hardscape transition does not meet the intent of the code. Please refine
the plaza area to provide more landscape planting depth, such as a 5' deep
bed at the top of the wall and/or with ornamental trees in tree grates.
Response - The planting beds along Limon were increased in depth and additional planting beds were
added to the top of the wall.
Comment Number: 12
Comment Originated: 12/09/2015
12/09/2015: Building elevations: For the second story cladding system and
other materials, the plans must show the material which will be used with the
final plans, and not an either/or material callout. Staff is very concerned that the
materials for the second story, in particular the stucco, are not an appropriate
choice for an institutional building, and do not work with the style of the building.
Prior to and in preparation for the hearing, please provide a color material
sample sheet. This can be photographic examples and material images and
incorporated into the elevation sheets. See Banner Health PDP elevation
sheets for an example. Also see redlines for signage and wall comments.
Response — Materials board has been provided and signage has been removed from the elevations.
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mraoasa.@Mcaov.com
Topic: General
Comment Number: 2 Comment Originated: 0810512015
12/09/2015: The sidewalk ramps at the corners of Limon & Iowa and Limon &
Illinois need to be built to City standards. They need to match the existing
access ramps. The Limon & Iowa ramps need to be built for detached
sidewalks on both legs, while the Limon & Illinois ramps need to be built forv/
detached on Limon and attached on Illinois.
08/05/2015: Please label the type of concrete treatment at the corners of Iowa
Drive and Limon Drive as well as Illinois Drive and Limon Drive
Response = Comers are now shown with a standard design
Comment Number: 11 Comment Originated: 12/09/2015
12/09/2015: The entrance angle for all driveway approaches shall be near 90
degrees to the centerline of the street for a minimum of 26 from the curb or
edge of pavement. What is the entrance angle? if it is +/-10 degrees, it must be
consistent for 25'.
Response — Per email from Marc R, do not need variance for current design
Comment Number: 12 Commep Originated: 12/09/2015
12/09/2015: Add a signature block, scale, and north arrow to sheet of the
Utility Plans.
Response —Added
Comment Number: 13 Comment Originated: 12/09/2015
12/09/2015: The 6' Pedestrian Easement on the southwest corner of the
property should be an Access Easement. Please change on the plat as well.
Response — Modified
Comment Number: 14 Comment Originated: 12/09/2015
12/09/2015: Label the dimensions of the drainage easement being shown on
Lot 3 on the Utility Plans. See redlines.
Response — Added
Department: Environmental Planning
Contact: Rebecca Everette, 970-416-2625, rj—vff-qU2@Mov.com
Topic: Lighting Plan
Comment Number: 2 Comment Originated: 12/02/2015.
12/02/2015: In regard to LED light fixtures, cooler color temperatures are
harsher at night and cause more disruption to circadian rhythms for both
humans and wildlife. Please consider a warmer color temperature (2700K or
3000K versions) for your LED light fixtures, rather than the 4000-4500K
versions.
Response — Lighting has been changed as requested to 3000K.
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchananfiilltcgov.com
Topic: Landscape Plans
Comment Number: 2
Comment Originated: 08/04/2015
08/04/2015:
The final landscape plan will need to identify all trees and landscape plants by
direct labeling them on the plan. Street trees should be selected from the City of
Fort Collins street tree list.
Response — Shade and ornamental trees have now been labeled and street trees are labeled using
species from the City of Fort Collins street tree list.
Comment Number: 3
08/04/2015:
Comment Originated: 08/04/2015
Skymaster English oak is no longer in nursery production. Due to likely
availability problems use another canopy shade tree in its place.
Response — Acknowledged
Comment Number: 6
12/08/2015:
Comment Originated: 12/08/2015
Show the locations of any other street lights and the locations where stop signs
will be located. Street tree placement from any of these fixtures should be
adjusted to meet the following standard.
Street Lights:
Canopy shade trees 40 feet
Ornamental trees 15 feet
Response — Required spacing provided
Stop Signs:
All trees 20 feet away from signs
Response — Required spacing provided
Comment Number: 7
Comment Originated: 12/08/2015
12/08/2015:
Evaluate street tree placement for line of site at the following comers:
trees to meet the spacing requirements on the north side of the building. If you
are not able to add another tree to meet this requirement, we can discuss other
options for enhanced landscaping along this side of the building.
Response — Additional ornamental trees as well as planters have been added to the north side of
the building to provide i'or the tree stocking requirements.
Comment Number: 4 Comment Originated: 08/04/2015
08/04/2015: Do you anticipate using any planters, seating, etc. on the south
side of the building? Please note locations on the landscape plan if applicable.
Response — Planters and benches have been added to the south plaza.
Comment Number: 5 Comment Originated: 08/04/2015
08/04/2015: Section 3.2.1(E)(4)(b) describes the requirements for parking lot
screening from the street. Such screening should have a minimum height of 30
inches and consist of a wall, fence, planter, earthen berm, plant material, or
some combination. This should cover a minimum of 70 percent of the length of
the street frontage of the parking lot. Please demonstrate how the proposal
meets this requirement, including a graphic depiction of parking lot screening
(as seen from the street).
Response — The parking lot is proposed to be thoroughly screened with plant material. A graphic depiction
has been provided on the landscape plan.
Comment Number: 6 Comment Originated: 08/04/2015
08/04/2015: Once final numbers and locations of plants have been determined,
please update the landscape plan with details regarding the locations, numbers,
and species diversity.
Response - Plant counts will be provided with the final landscape plan.
Topic: Plat
Comment Number: 1 Comment Originated: 08104/2015
08/04/2015: All references to "MMU" zoning on the plat should be corrected to
"MMN."
Response — Revised
Topic: Site Plan
Comment Number: 2 Comment Originated: 08/04/2015
08/04/2015: If the building changes from 2 stories to 1 story as noted in the
planning objectives, please note that the parking minimumslmaAmums and
other requirements may need to be adjusted. This could affect the layout of the
site plan as presented here.
Response — Acknowledged.
Comment Number: 7
Comment Originated: 08/05/2015
08/05/2015: The trash and recycling enclosure should be designed to allow
walk-in access (separate from the main service gates). Please show this on the
site plan.
2
Illinois and East Drake: The first tree along Illinois and the first tree along Drake.
Illinois and Limon: the first tree on Illinois should be shifted to the north. The first
tree along Limon may be in conflict with where a stop sign will be located and is
also close to the
DVJpV11JV' Gcorner.
'I^J iu.Vr�
AtcVVC %IJ .
East Drake and Iowa: Evaluate the first tree for better clearance of east bound
traffic on Drake.
Response — Plans have been updated.
Comment Number: 8
Comment Originated: 12/08/2015
12/08/2015:
Select landscape Plants that will be in the beds at the corner of Illinois and.
Limon and at Limon and Iowa that are low and less than 18 inches height.
Review plant selection with Clark Mapes in the Planning Department.
Response — Acknowledged.
Comment Number: 9
Comment Originated: 12/08/2015
12/08/2015:
Provide minimum tree species diversity that meets the LUC standard 3.2.1 D 3.
List the percent used of each tree that is used and check for minimum species
diversity.
Response — Species diversity has been added to the plant list.
Comment Number: 10 Comment Originated: 12/08/2015
12/08/2015:
Trees with tree grates along Illinois:
Provide a tree planting detail for the trees located in the sidewalk along Illinois
that will have tree grates. Grates should be 5 feet by feet or larger. Specify in the
detail the tree grate that will be used.
Response — A tree grate detail has been added to the plans.
Add a landscape note that says all
maintenance, repair and replacement of tree grates shall be the responsibility of
the adjacent property owner.
Response — Note has been added.
Department: Internal Services
Contact: Jason Holland, 970-224-6126, lolland(Mcgov.com
Topic: General
Comment Number: 4 Comment Originated: 12/14/2015
Per building services, Russ Hovland, The Warren credit union project shows the
building approx. 9ft from north PL and this will require 1-hour walls with 25%
windows/doors max.
Response — Site plan has been revised to provide 10.5' clearance
Contact: Rebecca Everette, 970-416-2625, reverette(Mcgov.com
Topic: General
Comment Number: 2
Comment Originated: 08/13/2015
GIS COMMENTS 08/13/2015: Addresses will be assigned by the GIS
Department after the plans have met final approval through Development
Review and are recorded with the City.
Response — Acknowledged.
Comment Number: 3 Comment Originated: 08/13/2015
GIS COMMENTS 08/13/2015: Projects with three or more tenant units require
the Unit Level Addressing form to be completed and submitted to the GIS
Department once plans have met final approval through Development Review
and are recorded with the City. This can occur anytime during construction, but
before any utilities or address signs are installed. All addressing will be
determined by the GIS Department and submitted to Poudre Fire Authority,
USPS, Building Services, and Fort Collins Utilities.. Failure to contact GIS and
determining addresses through other means may result in address changes.
The Unit Level Addressing form can be obtained by contacting the GIS office at
gis@fcgov.com or (970) 416-2483.
Response — Acknowledged.
Contact: Russell Hovland, 970-416-2341, rhovland cgov.com
Topic: Building Insp Plan Review
Comment Number: 1 Comment Originated: 07/24/2015
07/24/2015:
Building Permit Pre -Submittal Meeting:
Pre -Submittal meetings are offered to assist the designer/builder by assuring,
early on in the design,
that the new commercial or multi -family projects are on track to complying with
all of the adopted City
codes and Standards listed below. The proposed project should be in the early
to mid -design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi -family projects are advised to
call 416-2341 to schedule
a pre -submittal meeting. Applicants should be prepared to present site plans,
floor plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 Intemational Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code ([PC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the
fcgov.com web page to view them.
Accessibility: State, Law CRS 9-5 & ICCIANSI A117.1-2009.
Snow Load Live Load: 30 PSF 1 Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load:100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi -family and Condominiums 3 stories max: 2012 IECC residential
chapter.
3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial
chapter.
City of Fort Collins
Building Services
Plan Review
416-2341
Response — Acknowledged.
Department: Light And Power
Contact: Luke Unruh, 9704162724, lunruh@fcgov.com
Topic: General
Comment Number: 6 Comment Originated: 1210812015
Street trees will need to be adjusted based on the location of the streetlights.
Forty feet of clearance to the streetlight will need to be maintained by shade
trees and fifteen feet by ornamental trees.
Response — Required spacing provided
Department: Outside Agencies
Contact: Bob Rulli, Century Link,
Topic: General
Comment Number:
Comment Originated: 07/24/2015
CENTURY LINK 07/24/2015: No issues here. Developer/Building to work with
Century Link as needs dictate. I can work with them on specifics (MP at
property edge, entrance conduits, backboard space etc. Century Link has no
facilities in the ROW around this block so we will have a build out to reach
property edge. Also, there are facilities along E Drake (south side) so any
relocates necessary to support this build will be at developers expense.
Short of that looking forward to the project. Developer can reach out to me for
questions as I cover this area. Direct: (970) 490.7503 Cell: (970) 988.2120.
robert.rulliecenturylink.com.
Response — Acknowledged.
Contact: Jason Holland, 970-224-6126, *holland@Lci3ov.com
Topic: General
Comment Number: 3 Comment Originated: 12/14/2015
12114/2015: Comcast requests a 2 conduit from data room to transformer
area. Contact Don Kapperman for details.
Response — Acknowledged.
Contact: Xcel, ,
Topic: General
Comment Number: 2 Comment Originated: 08/25/2015
XCEL ENERGY 08/25/2015: This will require gas main extension to serve
customer.
Response — Acknowledged.
Department: PFA
Contact: Jim Lynxwiler, 970.416-280, llynxwiler@poudre-fire.org
Topic: General
Comment Number: 7 Comment Originated: 12/01/2015
PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM TEST
New buildings require a fire department, emergency communication system
evaluation after the core/shell but prior to final build out. For the purposes of this
section, fire walls shall not be used to define separate buildings. Where
adequate radio coverage cannot be established within a building, public -safety
radio amplification systems shall be designed and installed in accordance with
criteria established by the Poudre Fire Authority. Poudre Fire Authority Bureau
Admin Policy #07-01
Response — Acknowledged.
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-2932, ischlarn@ cgov.com
Topic: Erosion Control
Comment Number: 1
Comment Originated: 07/21/2015
11/30/2015: Waiting for Material Submittle FDP
08/03/2015: Waiting for Material Submittle FDP
07/21/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. Please submit; Erosion Control Plan,
Erosion Control Report, and an Escrow / Security Calculation. If you need
clarification concerning this section, or if there are any questions please contact
Jesse Schlam 970-218-2932 or email @ ischlam .fcgov.com
Response — Acknowledged.
Contact: Wes Lamarque, 970-416-2418, wlam9rau2@fcg0v.c0m
Topic: General
Comment Number: 5
12/09/2015: Stormwater is ready for a hearing.
Response — Acknowledged.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcountv(ai)-fcgov.com
Topic: Building Elevations
Comment Number: 1
12/08/2015: There are line over text issues. See redlines.
08/04/2015: No comments.
Response — Revised
Comment Originated: 12/09/2015
Comment Originated: 08104/2015
Topic: Construction Drawings
Comment Number: 2 Comment Originated: 08/04/2015
12/08/2015: Please change the legal description to "Lot 1, 3 & Tract A, Warren
Federal Credit Union - East Drake".
Response — Revised
08/04/2015: Please change the title to "Lot 2, Warren Federal Credit Union -
East Drake".
Comment Number: 3 Comment Originated: 08/04/2015
12/08/2015: Please show the elevation of benchmark 17-92 to hundredths.
08/04/2015: Please provide the following information for the Benchmark
Statement in the EXACT format shown below.
PROJECT DATUM: NAVD88
BENCHMARK # w/ DESCRIPTION
ELEVATION:
BENCHMARK # wl DESCRIPTION
ELEVATION:
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL
DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29
UNADJUSTED FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE,
THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED
= NAVD88 - X.XX6.
Response — Revised
Comment Number: 5 Comment Originated: 08/04/2015
12/08/2015: There are line over text issues. See redlines.
08/04/2015: There are line over text issues. See redlines.
Response — Revised
Topic: Landscape Plans
Comment Number: 13 Comment Originated: 12/08/2015
12/08/2015: There is text that needs to be masked. Mask all text in hatched
areas. See redlines.
Response — Revised
Comment Number: 14 Comment Originated: 12/08/2015
12/08/2015: Please add "- East Drake" to the titles. See redlines.
Response— Revised
Topic: Lighting Plan
Comment Number: 8 Comment Originated: 08/04/2015
12/08/2015: There are line over text issues. See redlines.
08/04/2015: No comments.
Response — Revised
Comment Number: 15 Comment Originated: 12/08/2015
12/08/2015: There are text over text issues. See redlines.
Response— Revised
Comment Number: 16 Comment Originated: 12/08/2015
12/08/2015: Please add "- East Drake" to the titles. See redlines.
Response — Revised
Comment Number: 17 Comment Originated: 12/08/2015
12108/2015: Please add "Electrical" to the title of sheet E1.0. See redlines.
Response — Revised
Topic: Plat
Comment Number: 18 Comment Originated: 12/08/2015
12/08/2015: Please change "Engineering Department" in the Notice Of Other
Documents statement to "Clerk". See redlines.
Response— Revised
Topic: Site Plan
Comment Number: 10 Comment Originated: 08/04/2015
12/08/2015: Please change the legal description to "Lot 1, 3 & Tract A, Warren
Federal Credit Union - East Drake".
Response — Revised
08/04/20.15: Please change the legal description to "Lot 2, Warren Federal
Credit Union - East Drake".
Comment Number: 19 Comment Originated: 12/08/2015
12/08/2015: There are line over text issues. See redlines.
Response — Revised
Comment Number: 20 Comment Originated: 12/08/2015
12/08/2015: Please add "- East Drake" to the title. See redlines.
Response — Revised
Department: Traffic Operation
Contact: Martina Wilkinson, 970-221-6887, mwilkinsonffcaov.com
Topic: General
Comment Number: 2
12/01/2015: no new comments
Response — Acknowledged
Department: Water Conservation
Contact: Eric Olson, 970-221-6704, eolson(&Jcaov.com
Topic: General
Comment Originated: 12/01/2015
Comment Number: 1 Comment Originated: 08/04/2015
08/04/2015: Irrigation plans are required no later than at the time of building
permit. The irrigation plans must comply with the provisions outlined in Section
3.2.1(J) of the Land Use Code. Direct questions concerning irrigation
requirements to Eric Olson, at 221-6704 or eolson(&fcgov.com
Response — Acknowledged
Department: Water -Wastewater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamaraue00-fcgov.com
Topic: General
Comment Number: 1 Comment Originated:
08/04/2015: Please add all water and sewer details during final compliance.
Response — Acknowledged
Department: Zoning
Contact: GaryLopez, 970-416-2338, gloaezc cgov.com
Topic: Building Elevations
Comment Number: 2 Comment Originated:
11/20/2015: Signage will be approved by separate review requiring sign
permit. However, please note the world globe appearing on the building may
be considered a sign. If that is the case then the height of the sign cannot be
over 7' in height. Currently the sign scales out at 11' in height.
Response — Acknowledged. Sign has been removed
Topic: Site Plan
Comment Number: 1
11/20/2015: Please indicate building dimensions on site plan.
Response — Building dimensions have been added.
08/04/2015
11/20/2015
Comment Originated: 11/20/2015
Response — The trash enclosure has been revised to allow walk-in access.
Department: Engineering Development Review
Contact: Marc Ragasa, 970.221.6603, mragasafficgov.com
Topic: General
Comment Number: 2 Comment Originated: 08105/2015
08/05/2015: Please label the type of concrete treatment at the comers of Iowa
Drive and Limon Drive as well as Illinois Drive and Limon Drive
Response — Hardscape enhancement language has been added to the site plan.
Comment Number: 3 Comment Originated: 08/05/2015
08/05/2015: It appears that the stairs along Limon Drive at the edge of the
ROW line. Please verify that the handrails in these locations will not protrude
into the ROW.
Response — Stair geometry has been revised to prevent the handrails from protruding into the ROW.
Comment Number: 4
Comment Originated: 08/05/2015
08/05/2015: The proposed street cross section for Limon Drive does not meet
City standards. A minimum 6' parkway and a 5' sidewalk with a 9' Utility
Easement are required for a commercial local street. If an attached sidewalk is
desired, the Illinois Drive Cross Section depicted on the Utility Plans for Rigden
Farm 8th Filing, The Shops at Rigden Farm can be used. This calls for a 6'-6"
walk, 4' tree grate and a 1' additional walk between the tree grate and 6' curb.
Response — The crass section for Limon has been revised to meet City standards.
Comment Number: 5
Comment Originated: 08/05/2015
08/05/2015: Type III Barricades will be needed on the north end of the sidewalk
comer on Illinois and Limon Drive. See redlines.
Response — All of the perimeter sidewalks are now proposed to be built
Comment Number: 6 Comment Originated: 08/05/2015
08/05/2015: Please clearly define the lot boundaries on the Utility Plans.
Response — Lot lines have been revised and are now more square.
Comment Number: 7
Comment Originated: 08/05/2015
08/05/2015: It is unclear what is being proposed for this PDP. Please only
show details for the Lot 2 improvements on the Utility Plan. Is the storm pipe that
extends into Lot 1 a part of this submittal? Will there be off site improvements
for the grading required on Lot 1? Will the sidewalk along Illinois Drive be
constructed with this proposal?
Response — Lot 1 and Lot 2 are now clearly not included in the PDP. The lots will be graded.
Comment Number: 8
Comment Originated: 08/05/2015
08/05/2015: There seems to be a discrepancy between the elevations and the
Utility/Site Plans. The elevation drawings show a retaining wall for the proposed
ramps to run parallel with the sidewalk on Iowa Drive. There is a minimum 2'
3
setback required for walls that run parallel to sidewalks.
Response — 2' setback has been provided between the walls and the sidewalk.
Comment Number: 10 Comment Originated: 08/06/2015
08/06/2015: Utility Plans show 4.5' wide sidewalks along Iowa Drive. The
minimum sidewalk width for a commercial local street is 5'.
Response — A 5' sidewalk has been provided.
Contact: Sheri Langenberger, 970-221-6573, slanoenbergerftgov.com
Topic: General
Comment Number: 9 Comment Originated: 08/05/2015
08/05/2015: The project owes an additional $197.50 for the PDP TDRF. It
looks like the project did not include the entire area being platted within the
calculations.
Response — Additional fees have been provided with the resubmittal.
Contact: Tom Knostman, tknostman&cgov.com
Topic: General
Comment Number: 1 Comment Originated: 08/0412015
FROM STREETS DEPARTMENT 08/04/2015: Need to see civil drawings for
ROW improvements.
Department: Environmental Planning
Contact: Kelly Kimple, kkimple ccov.com
Topic: General
Comment Number:
Comment Originated: 08/04/2015
08/04/2015: Our city has an established identity as a forward -thinking
community that cares about the quality of life it offers its citizens and has many
sustainability programs and goals that may benefit your project. Of particular
interest may be the:
• ClimateWise program: http://www.fcgov.com/climatewise/
• Zero Waste Plan and the Waste Reduction and Recycling Assistance
Program (WRAP):
http://www.fcgov.com/recyclinglpdf/_20120404_WRAP_ProgramOverview.pdf,
contact Caroline Mitchell at 970-221-6288 or cmtichell@fcgov.com
• Green Building and the Climate Action Plan:
http:/twww.fcgov.com/enviro/green-building.php, contact Tony Raeker at 970-
416-4238 or traeker@fcgov.com
• Nature in the City Strategic Plan:
http://www.fcgov.com/planning/natureinthecity/?key=advanceplanning/natureinthecity/, contact Justin
Scharton at 970-221-6213
4
or jscharton@fcgov.com
Please consider the City's sustainability goals and ways for your development
to engage with these efforts.
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchanang&aov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 08104/2015
08/04/2015:
Use the newly developed project and landscape notes on the project plans.
These notes are available from the City Planner.
Response — Revised
Comment Number: 2
Comment Originated: 08/04/2015
08/04/2015:
The final landscape plan will need to identify all trees and landscape plants by
direct labeling them on the plan. Street trees should be selected from the City of
Fort Collins street tree list.
Response — Plant callouts will be provided on the final landscape plan.
Comment Number: 3
Comment Originated: 08/04/2015
08/04/2015:
Skymaster English oak is no longer in nursery production. Due to likely
availability problems use another canopy shade tree in its place.
Response — Acknowledged.
Comment Number: 4
Comment Originated: 08/04/2015
08/04/2015:
If there are existing trees on site schedule an on -site meeting with the City
Forester to obtain tree inventory information that is required on the plans.
Response — There are no existing trees on site.
Comment Number: .5
Comment Originated: 08/04/2015
08/04/2015:
Is it possible to increase the planting area where trees are shown along Limon
Drive by a foot to 5 feet wide to provide a little more room for the trees.
Response — The tree law along Limn drive averages 5.5' with the latest plan.
Department: Internal Services
Contact: Russell Hovland, 970-416-2341, rhovlandWcgov.com
Topic: Building Insp Plan Review
Comment Number: 1
Comment Originated: 07/24/2015
07/24/2015:
Building Permit Pre -Submittal Meeting:
Pre -Submittal meetings are offered to assist the designer/builder by assuring,
5
early on in the design,
that the new commercial or multi -family projects are on track to complying with
all of the adopted City
codes and Standards listed below. The proposed project should be in the early
to mid -design stage for
this meeting to be effective and is typically scheduled after the Current Planning
conceptual review
meeting. Applicants of new commercial or multi -family projects are advised to
call 416-2341 to schedule
a pre -submittal meeting. Applicants should be prepared to present site plans,
floor plans, and elevations
and be able to discuss code issues of occupancy, square footage and type of
construction being proposed.
Construction shall comply with the following adopted codes as amended:
2012 International Building Code (IBC)
2012 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
2012 International Mechanical Code (IMC)
2012 International Fuel Gas Code (IFGC)
2012 International Plumbing Code (IPC) as amended by the State of Colorado
2014 National Electrical Code (NEC) as amended by the State of Colorado
Fort Collins has amendments to most of the codes listed above. See the
fcgov.com web page to view them.
Accessibility: State Law CRS 9-5 & ICC/ANSI Al 17.1-2009.
Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF.
Frost Depth: 30 inches.
Wind Load:100- MPH 3 Second Gust Exposure B.
Seismic Design: Category B.
Climate Zone: Zone 5
Energy Code Use
1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC.
2. Multi -family and Condominiums 3 stories max: 2012 IECC residential
chapter.
3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial
chapter.
City of Fort Collins
Building Services
Plan Review
416-2341
Response — Acknowledged
Department: Light And Power
Contact: Luke Unruh, 9704162724, Iunruhb-fcaov.com
Topic: General
Comment Number: 1 Comment Originated: 08/04/2015
08/04/2015: Light and Power has electric facilities on the south side of Drake
Rd that could be utilized to provide power to the proposed site.
Response — Acknowledged
s
Comment Number: 2
Comment Originated: 08/04/2015
08/04/2015: Please provide a one line diagram and a C-1 form to Light and
Power Engineering. The C-1 form can be found at:
http://zeus fimov com/uols-procedurestfiles/Encl ikiWl(Pdfs/C/C-1 Form.adf
Response — One fine diagram will be provided.
Comment Number: 3
Comment Originated: 08/04/2015
08/04/2015: d.) Contact Light and Power Engineering to coordinate the
transformer and electric meter locations, please show the locations on the utility
plans. Transformer must be within 10' of an asphalt/concrete surface. Pay close
attention to the transformer clearances in the Electric Construction Policies,
Practices & Procedures.
Response — Transformer has been shown on the site and utility plans.
Comment Number: 4
Comment Originated: 08/04/2015
08/04/2015: e.) Please contact Luke Unruh at Light & Power Engineering if
you have any questions at 970.416-2724. Please reference our policies,
development charge processes, and use our fee estimator at
http:/twww.ftov.com/ublftk,-Ausiness/builders-and-developers
Response — Acknowledged
Comment Number: 5 Comment Originated: 08/04/2015
08/04/2015: Development and capacity charges will apply at owner's expense.
Response — Acknowledged
Department: Outside Agencies
Contact: Bob Rulli, Century Link,
Topic: General
Comment Number:
Comment Originated: 07/24/2015
07/24/2015: No issues here. Developer/Building to work with Century Link as
needs dictate. I can work with them on specifics (MP at property edge, entrance
conduits, backboard space etc. Century Link has no facilities in the ROW
around this block so we will have a build out to reach property edge. Also, there
are facilities along E Drake (south side) so any relocates necessary to support
this build will be at developers expense.
Short of that looking forward to the project. Developer can reach out to me for
questions as I cover this area. Direct: (970) 490.7503 Cell: (970) 988.2120.
robert.rulligbcenturvlink.com.
Response — Acknowledged
7
Department: PFA
Contact: Jim Lynxwiler, 970416-2869, 11ynxwiler0boudre-fire.ore
Topic: General
Comment Number: 1 Comment Originated: 07131/2015
07/31/2015: WATER SUPPLY
Minimum water supply requirements have been met with the existing utility
infrastructure available in the area. Nothing further required.
Response — Acknowledged
Comment Number: 2
Comment Originated: 07/31/2015
07/31/2015: GENERAL FIRE ACCESS
Fire access is required to within 150' of all exterior portions of the ground floor.
This minimum fire access requirement has not been met with the site plan,
however as the building will be equipped with an automatic sprinkler system, the
52 out of access condition is permitted.
Response — Acknowledged
Comment Number: 3 Comment Originated: 07/31/2015
07/31/2015: BUILDINGS EXCEEDING THREE STORIES OR 30 FEET IN
HEIGHT
Minimum aerial access requirements have not been met as per code language
provided below. In circumstances when aerial apparatus access cannot be met
due to site constraints, upgraded building design and systems may allow for
alternative means of compliance. Further discussion would be needed.
AERIAL FIRE APPARATUS ACCESS ROADS - WHERE REQUIRED
> IFC D105.1: Where the vertical distance between the grade plane and the
highest roof surface exceeds 30 feet, approved aerial fire apparatus access
roads shall be provided. For purposes of this section, the highest roof surface
shall be determined by measurement to the eave of a pitched roof, the
intersection of the roof to the exterior wall, or the top of parapet walls, whichever
is greater.
AERIAL FIRE APPARATUS ACCESS ROADS - WIDTH
> IFC D105.2; FCLUC 3.6.2(B)2006; and Local Amendments: Aerial fire
apparatus access roads shall have a minimum unobstructed width of 30 feet,
exclusive of shoulders, in the immediate vicinity of the building or portion
thereof.
AERIAL FIRE APPARATUS ACCESS ROADS - PROXIMITY TO BUILDING
> IFC D105.3: At least one of the required access routes meeting this condition
shall be located within a minimum of 15 feet and a maximum of 30 feet from the
building, and shall be positioned parallel to one entire side of the building. The
side of the building on which the aerial fire apparatus access road is positioned
shall be approved by the fire code official.
Response — Building is only one story now (no second floor) and is 23' high except for fireplace/sign wall
element that is 36' high.
8
Comment Number: 4
Comment Originated: 07/31/2015
07/31/2015: PARAPET HEIGHT
From submitted materials, it appears the parapet height above the roof line will
be 5'. In order to allow firefighters access on and off the roof during ladder truck
operations, the parapet height would need to be somewhat reduced in all or
some portions, unless alternative means of gaining roof access have been
approved (See comment no. 4 above).
Response — Most parapets are 4' high now.
Comment Number: 5
Comment Originated: 07/31/2015
07/31/2015: FDC
> IFC 912.2: Fire Department Connections shall be installed in accordance with
NFPA standards. Fire department connections shall be located on the street
side of buildings, fully visible and recognizable from the street or nearest point
of fire department vehicle access. The location of the FDC shall be approved by
the fire department.
Response — Acknowledged. We are planning on locating FDC on east elevation accessed from Iowa Drive.
Comment Number: 6
Comment Originated: 07/31/2015
07/31/2015: KEY BOXES REQUIRED
2012 IFC 506.1 and Poudre Fire Authority Bureau Policy 88-20: Poudre Fire
Authority requires at least one key box ('Knox Box") to be mounted in an
approved, exterior location (or locations) on every new or existing building
equipped with a required fire sprinkler or fire alarm system. The box shall be
positioned 3 to 7 feet above finished floor and within 10 feet of the front door, or
closest door to the fire alarm panel. Exception can be made by the PFA if it is
more logical to have the box located somewhere else on the structure
Response — Acknowledged
Department: Stormwater Engineering
Contact: Jesse Schlam, 970-218-293Z 'schiam@Mov.com
Topic: Erosion Control
Comment Number: 1
Comment Originated: 07/21/2015
08/03/2015: Waiting for Material Submttle FDP
07/21/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and
Sediment Control Materials need to be submitted for FDP. The erosion control
requirements are in the Stormwater Design Criteria under the Amendments of
Volume 3 Chapter 7 Section 1.3.3. Please submit; Erosion Control Plan,
Erosion Control Report, and an Escrow / Security Calculation. If you need
clarification concerning this section, or if there are any questions please contact
Jesse Schlam 970-218-2932 or email @ ischlam( fcaov.com
Response — Acknowledged
Contact: Wes Lamarque, 970-416-2418, wlamarauMfcgov.com
Topic: General
Comment Number: 2 Comment Originated: 08/04/2015
08/04/2015: Please compare the flows for each sub-bsin as well. The flow to
the inlet in Iowa Drive is proposed to increase. Please verify the inlet and storm
9