Loading...
HomeMy WebLinkAboutWARREN FEDERAL CREDIT UNION - EAST DRAKE - Filed CS-COMMENT SHEETS - 2016-09-13` It of Fart Collins Community Development and August 07, 2015 Jerod Huwa BHA Design, Inc. 1603 Oakridge Dr. Fort Collins, CO 80525 RE: Warren Federal Credit Union, PDP150011, Round Number 1 Neighborhood SOMIC" 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov.com1d& elOPmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Rebecca Everette, at 970-416-2625 or reverette@fcgov.com. Comment Summary: Department: Planning Services Contact: Rebecca Everette, 970 416-2625, revens1190001com Topic: General Comment Number: 8 Comment Originated: 08/05/2015 08/05/2015: Much of the previous conversation on this project centered around activating the comer at Illinois Drive and Limon Drive. However, the current development plan does not activate that comer, and defers public improvements and development there to a later project. I am concerned that development at that comer is not predictable with this plan and may not fully integrate (in the future) with the project that is currently proposed. Lets discuss options for ensuring that the ultimate development of the western lot is consistent with the plans shown here. If the western parcel is ultimately included in the development plan, as discussed at the staff review meeting, that would help to address my concerns. Response — Pedestrian improvements have been included in the first phase construction of the project. The comer of Illinois and Limon are proposed to be activated through the use of enhanced pedestrian plaza areas that lead to the larger plaza areas associated with the building. Topic: Landscape Plans Comment Number: 3 Comment Originated: 08/04/2015 08/04/2015: Section 3.2.1(D)(1)(c) of the LUC requires "full tree stocking" along all high use or high visibility sides of a building. This standard appears to be met on the south and east sides of the building, but there are not enough sewer have capacity. Response — We have modelled the new total flow to the Iowa inlet with the HGL from the original report to verify it will not flood the immediate downstream pipe. Comment Number: 3 Comment Originated: 08/04/2015 08/04/2015: Please provide the LID table to verify the site is meeting the LID requirements. This detail can be electronically delivered upon request. Response —Added. Comment Number: 4 Comment Originated: 08/04/2015 08/04/2015: The porous paver detail is not per City Standards. Please provide a detail that is consistent with the City's porous paver schematic. Response — Revised. Department: Technical Services Contact: Jeff County, 970-221-6588, icounty0fcgov.com Topic: Building Elevations Comment Number: 1 08/04/20.15: No comments. Comment Originated: 08/04/2015 Topic: Construction Drawings Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: Please change the title to "Lot 2, Warren Federal Credit Union - East Drake". Response — Revised — this is now Lot 3 and Tract A for the PDP. Comment Number: 3 Comment Originated: 08/04/2015 08/04/2015: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XXL. Response — Revised Comment Number: 4 Comment Originated: 08/04/2015 10 . e - 08/04/2015: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response— Revised Comment Number: 5 Comment Originated: 08/04/2015 08/04/2015: There are line over text issues. See redlines. Response — Revised Comment Number: 6 Comment Originated: 08/04/2015 08/04/2015: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response — Revised. Topic: Landscape Plans Comment Number: 7 Comment Originated: 08/04/2015 08/04/2015: The lighter background text & linework marked is not acceptable. It will not scan or reproduce. Please darken it up. See redlines. Response — Linework screening has been corrected Topic: Lighting Plan Comment Number: 8 08/04/2015: No comments. Comment Originated: 08/04/2015 Topic: Plat Comment Number: 9 Comment Originated: 08/04/2015 08/04/2015: Please change the titleblock to match the title. See redlines. Response — Revised. Topic: Site Plan Comment Number: 10 Comment Originated: 08/04/2015 08/04/2015: Please change the legal description to "Lot 2, Warren Federal Credit Union - East Drake". Response — Revised Comment Number: 11 Comment Originated: 08/04/2015 08/04/2015: There is text that needs to be rotated 180 degrees. See redlines. Response — Revised Comment Number: 12 Comment Originated: 08/04/2015 08/04/2015: The lighter background text & linework marked is not acceptable. It will not scan or reproduce. Please darken it up. See redlines. Response — Revised Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinso i ft9ov.com Topic: General Comment Number: 1 Comment Originated: 08/04/2015 11 08/04/2015: Since access spacing, sidewalk width etc along Illinios is a concern, it would be helpful on the plans to more clearly indicate that the Lot 1 is not a part of this submittal (perhaps shaded back more..) Response — This future drive has been removed from the plan altogether. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson(occgov.com Topic: General Comment Number: 1 Comment Originated: 08/04/2015 08/04/2015: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson(@fcgov.com Response — Acknowledged Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wiamarguefficgov.com Topic: General Comment Number: 1 Comment Originated: 08/04/2015 08/04/2015: Please add all water and sewer details during final compliance. Response — Acknowledged Department: Zoning Contact: Gary Lopez, 970-416-2338, gloaez(afcgov.com Topic: Site Plan Comment Number: Comment Originated: 07/24/2015 07/24/2015: 1 believe the build to lines for streetfront buildings (LUC 3.5.3[C][21) would require the building be moved towards the NE corner of the property near the intersection. Response — Revised Please include the following comment(s) from GIS: Comment Number:1 Addresses will be assigned by the GIS Department after the plans have met final approval through Development Review and are recorded with the City. Comment Number: 2 Projects with three or more tenant units require the Unit Level Addressing form to be completed and submitted to the GIS Department once plans have met final approval through Development Review and are recorded with the City. This can occur anytime during construction, but before any utilities or address signs are installed. All addressing will be determined by the GIS Department and submitted to Poudre Fire Authority, USPS, Building Services, and Fort Collins Utilities. Failure to contact GIS and determining addresses through other means may result in address changes. The Unit Level Addressing form can be obtained by contacting the GIS office at gisafcgov.com or (970) 416-2483. 12 Marc Ragasa From: Mike Oberlander <moberlander@interwestgrp.com> Sent: Wednesday, December 09, 2015 4:48 PM To: Marc Ragasa Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider Subject: WFCU Additional Information Attachments: WFCU WALK GRADING.pdf; ILLINOIS SECTION.pdf; Seven Generations Drive - No Variance.pdf; WFCU 5 Degree Entry Drive.pdf Marc - Wanted to respond to a couple of your comments and see if we can satisfy you so we can get to a hearing. Curb Ramps: We talked after the meeting and we think it will be OK to have the ramps standard at the corners and not have pots, colors, or anything in the ROW. You have a comment to match the ramps on the opposite sides of the street — based on what I can see on an aerial and on PDP plans for the development to the south, I think we are — we are matching the curb drops that were built when the street was built. The attached grading plan shows the ramps. Section for Illinois: The section we want is the one that was approved when Illinois was built — cover sheet of those plans are attached and the section is on the bottom of the sheet. We can do the 5' tree grates and the "walk" area will still be 6' to ROW (it is a 12' dim from FL of curb to ROW). Except at the 2 inlets, I plan to have this entire walk at 2%. 1 think the issue at Subway is that there is no utility easement, so that is a zero lot line setup. On our property we have the 9' UE, so the buildings will be back from the walk and grades can be adjusted outside of the ROW. The grading plan shows what I want to do here. Drive entry: I attached my old plans for the Seven Generations Driveway — I looked at the notes sheet and we did not get a variance for this. I also have attached a drawing showing if we revise the drive to a tangent section that intersects the street at 5 degrees. This is shown in red and meets standards without any variance. I think on 7 Gens, I argued that the little curve looked better that the skewed tangent and Sheri and Susan said good enough. If we can leave the curve without a variance, I would like to do that, if we need to prepare, submit and pay for a variance, we will change to the red, tangent line. I think if we can agree on these 3 points, it sounds like you will be good for hearing. Please let us know. Thanks. Mike Michael Oberlander, PE, LEED AP Interwest Consulting Group DIRECT — 970-460-8471 C — 970.631.2671 m Marc Ragasa From: Mike Oberlander <moberlander@interwestgrp.com> Sent: Friday, December 11, 2015 7:50 AM To: Marc Ragasa Cc: 'Michael McBride';'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider Subject: RE: WFCU Additional Information The overall dimension from face of curb to back of walk is 12'. 1 will work with BHA, but we think the 5' tree grate will start 12" behind face of curb so we can build the concrete to hold the frames and not take out any existing curb). That would leave 6'-0" clear behind the grate. That may change to 5'-6", but I don't think so. We will detail on the final plans. Thanks for working with me quickly on this. Mike Michael Oberlander, PE, LEED AP Interwest Consulting Group DIRECT — 970-460-8471 C — 970.631.2671 From: Marc Ragasa [mailto:mragasaCalfcgov.com] Sent: Thursday, December 10, 2015 3:24 PM To: Mike Oberlander Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider Subject: RE: WFCU Additional Information Mike, I'm not quite sure what the cross section of Illinois Drive would look like. Are we going to have curb, 1' behind curb, 5' tree grate and a 5'-6" walk (11'-6" with 6" curb) as opposed to 6'-6" curb? Let's just make sure we depict this cross section on final plans that depict the larger tree grates. Engineering would support the driveway as proposed, without the need of a variance. Tha nk you, Marc Ragasa City of Fort Collins Engineering Department 970-221-6603 mragasaCaD-fcaov.com From: Mike Oberlander [mailto:moberlanderC&interwestgrp.com] Sent: Wednesday, December 09, 2015 4:48 PM To: Marc Ragasa Cc: 'Michael McBride'; 'Gopal Shrestha'; David Kress; Jason Holland; Erika Schneider Subject: WFCU Additional Information Marc - Wanted to respond to a couple of your comments and see if we can satisfy you so we can get to a hearing. Curb Ramps: We talked after the meeting and we think it will be OK to have the ramps standard at the corners and not have pots, colors, or anything in the ROW. You have a comment to match the ramps on the opposite sides of the street — based on what I can see on an aerial and on PDP plans for the development to the south, I think we are — we are matching the curb drops that were built when the street was built. The attached grading plan shows the ramps. Section for Illinois: The section we want is the one that was approved when Illinois was built — cover sheet of those plans are attached and the section is on the bottom of the sheet. We can do the 5' tree grates and the "walk" area will still be 6' to ROW (it is a 12' dim from FL of curb to ROW).` Except at the 2 inlets, I plan to have this entke walk at 2%. 1 think the issue at Subway is that there is no utility easement, so that is a zero lot line setup. On our property we have the 9' UE, so the buildings will be back from the walk and grades can be adjusted outside of the ROW. The grading plan shows what I want to do here. Drive entry: I attached my old plans for the Seven Generations Driveway — I looked at the notes sheet and we did not get a variance for this. I also have attached a drawing showing if we revise the drive to a tangent section that intersects the street at 5 degrees. This is shown in red and meets standards without any variance. I think on 7 Gens, I argued that the little curve looked better that the skewed tangent and Sheri and Susan said good enough. If we can leave the curve without a variance, I would like to do that, if we need to prepare, submit and pay for a variance, we will change to the red, tangent line. I think if we can agree on these 3 points, it sounds like you will be good for hearing. Please let us know. Thanks. Mike Michael Oberlander, PE, LEED AP Interwest Consulting Group DIRECT— 970-460-8471 C — 970.631.2671 atypf o t Cottins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov.cw Vdeve1opmentrevfew December 14, 2015 . Jerod Huwa BHA Design, Inc. 1603 Oakridge Dr. Fort Collins, CO 80525 RE: Warren Federal Credit Union, PDP150011, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126orjholland@fcgov.com. Comment Summary: Department: Planning Services Contact: Jason Holland, 970-224-6126, jholland gov.com Topic: General Comment Number: 9 Comment Originated: 12/09/2015 12/09/2015: Please see redline plans for detailed comments. Response — Revised per redlines Comment Number: 10 Comment Originated: 12/09/2015 12/09/2015: Tree grates along the Illinois Drvie must be 5' if feasible. Also perimeter evergreen material must be incorporated into parking lot screening. Response - The tree grates have been resized to 5'x5' and evergreen plant material was added to the parking lot screening. Comment Number: 11 Comment Originated: 12/09/2015 12109/2015: Need more landscape transition depth along Limon Drive. Wall/hardscape transition does not meet the intent of the code. Please refine the plaza area to provide more landscape planting depth, such as a 5' deep bed at the top of the wall and/or with ornamental trees in tree grates. Response - The planting beds along Limon were increased in depth and additional planting beds were added to the top of the wall. Comment Number: 12 Comment Originated: 12/09/2015 12/09/2015: Building elevations: For the second story cladding system and other materials, the plans must show the material which will be used with the final plans, and not an either/or material callout. Staff is very concerned that the materials for the second story, in particular the stucco, are not an appropriate choice for an institutional building, and do not work with the style of the building. Prior to and in preparation for the hearing, please provide a color material sample sheet. This can be photographic examples and material images and incorporated into the elevation sheets. See Banner Health PDP elevation sheets for an example. Also see redlines for signage and wall comments. Response — Materials board has been provided and signage has been removed from the elevations. Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mraoasa.@Mcaov.com Topic: General Comment Number: 2 Comment Originated: 0810512015 12/09/2015: The sidewalk ramps at the corners of Limon & Iowa and Limon & Illinois need to be built to City standards. They need to match the existing access ramps. The Limon & Iowa ramps need to be built for detached sidewalks on both legs, while the Limon & Illinois ramps need to be built forv/ detached on Limon and attached on Illinois. 08/05/2015: Please label the type of concrete treatment at the corners of Iowa Drive and Limon Drive as well as Illinois Drive and Limon Drive Response = Comers are now shown with a standard design Comment Number: 11 Comment Originated: 12/09/2015 12/09/2015: The entrance angle for all driveway approaches shall be near 90 degrees to the centerline of the street for a minimum of 26 from the curb or edge of pavement. What is the entrance angle? if it is +/-10 degrees, it must be consistent for 25'. Response — Per email from Marc R, do not need variance for current design Comment Number: 12 Commep Originated: 12/09/2015 12/09/2015: Add a signature block, scale, and north arrow to sheet of the Utility Plans. Response —Added Comment Number: 13 Comment Originated: 12/09/2015 12/09/2015: The 6' Pedestrian Easement on the southwest corner of the property should be an Access Easement. Please change on the plat as well. Response — Modified Comment Number: 14 Comment Originated: 12/09/2015 12/09/2015: Label the dimensions of the drainage easement being shown on Lot 3 on the Utility Plans. See redlines. Response — Added Department: Environmental Planning Contact: Rebecca Everette, 970-416-2625, rj—vff-qU2@Mov.com Topic: Lighting Plan Comment Number: 2 Comment Originated: 12/02/2015. 12/02/2015: In regard to LED light fixtures, cooler color temperatures are harsher at night and cause more disruption to circadian rhythms for both humans and wildlife. Please consider a warmer color temperature (2700K or 3000K versions) for your LED light fixtures, rather than the 4000-4500K versions. Response — Lighting has been changed as requested to 3000K. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchananfiilltcgov.com Topic: Landscape Plans Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: The final landscape plan will need to identify all trees and landscape plants by direct labeling them on the plan. Street trees should be selected from the City of Fort Collins street tree list. Response — Shade and ornamental trees have now been labeled and street trees are labeled using species from the City of Fort Collins street tree list. Comment Number: 3 08/04/2015: Comment Originated: 08/04/2015 Skymaster English oak is no longer in nursery production. Due to likely availability problems use another canopy shade tree in its place. Response — Acknowledged Comment Number: 6 12/08/2015: Comment Originated: 12/08/2015 Show the locations of any other street lights and the locations where stop signs will be located. Street tree placement from any of these fixtures should be adjusted to meet the following standard. Street Lights: Canopy shade trees 40 feet Ornamental trees 15 feet Response — Required spacing provided Stop Signs: All trees 20 feet away from signs Response — Required spacing provided Comment Number: 7 Comment Originated: 12/08/2015 12/08/2015: Evaluate street tree placement for line of site at the following comers: trees to meet the spacing requirements on the north side of the building. If you are not able to add another tree to meet this requirement, we can discuss other options for enhanced landscaping along this side of the building. Response — Additional ornamental trees as well as planters have been added to the north side of the building to provide i'or the tree stocking requirements. Comment Number: 4 Comment Originated: 08/04/2015 08/04/2015: Do you anticipate using any planters, seating, etc. on the south side of the building? Please note locations on the landscape plan if applicable. Response — Planters and benches have been added to the south plaza. Comment Number: 5 Comment Originated: 08/04/2015 08/04/2015: Section 3.2.1(E)(4)(b) describes the requirements for parking lot screening from the street. Such screening should have a minimum height of 30 inches and consist of a wall, fence, planter, earthen berm, plant material, or some combination. This should cover a minimum of 70 percent of the length of the street frontage of the parking lot. Please demonstrate how the proposal meets this requirement, including a graphic depiction of parking lot screening (as seen from the street). Response — The parking lot is proposed to be thoroughly screened with plant material. A graphic depiction has been provided on the landscape plan. Comment Number: 6 Comment Originated: 08/04/2015 08/04/2015: Once final numbers and locations of plants have been determined, please update the landscape plan with details regarding the locations, numbers, and species diversity. Response - Plant counts will be provided with the final landscape plan. Topic: Plat Comment Number: 1 Comment Originated: 08104/2015 08/04/2015: All references to "MMU" zoning on the plat should be corrected to "MMN." Response — Revised Topic: Site Plan Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: If the building changes from 2 stories to 1 story as noted in the planning objectives, please note that the parking minimumslmaAmums and other requirements may need to be adjusted. This could affect the layout of the site plan as presented here. Response — Acknowledged. Comment Number: 7 Comment Originated: 08/05/2015 08/05/2015: The trash and recycling enclosure should be designed to allow walk-in access (separate from the main service gates). Please show this on the site plan. 2 Illinois and East Drake: The first tree along Illinois and the first tree along Drake. Illinois and Limon: the first tree on Illinois should be shifted to the north. The first tree along Limon may be in conflict with where a stop sign will be located and is also close to the DVJpV11JV' Gcorner. 'I^J iu.Vr� AtcVVC %IJ . East Drake and Iowa: Evaluate the first tree for better clearance of east bound traffic on Drake. Response — Plans have been updated. Comment Number: 8 Comment Originated: 12/08/2015 12/08/2015: Select landscape Plants that will be in the beds at the corner of Illinois and. Limon and at Limon and Iowa that are low and less than 18 inches height. Review plant selection with Clark Mapes in the Planning Department. Response — Acknowledged. Comment Number: 9 Comment Originated: 12/08/2015 12/08/2015: Provide minimum tree species diversity that meets the LUC standard 3.2.1 D 3. List the percent used of each tree that is used and check for minimum species diversity. Response — Species diversity has been added to the plant list. Comment Number: 10 Comment Originated: 12/08/2015 12/08/2015: Trees with tree grates along Illinois: Provide a tree planting detail for the trees located in the sidewalk along Illinois that will have tree grates. Grates should be 5 feet by feet or larger. Specify in the detail the tree grate that will be used. Response — A tree grate detail has been added to the plans. Add a landscape note that says all maintenance, repair and replacement of tree grates shall be the responsibility of the adjacent property owner. Response — Note has been added. Department: Internal Services Contact: Jason Holland, 970-224-6126, lolland(Mcgov.com Topic: General Comment Number: 4 Comment Originated: 12/14/2015 Per building services, Russ Hovland, The Warren credit union project shows the building approx. 9ft from north PL and this will require 1-hour walls with 25% windows/doors max. Response — Site plan has been revised to provide 10.5' clearance Contact: Rebecca Everette, 970-416-2625, reverette(Mcgov.com Topic: General Comment Number: 2 Comment Originated: 08/13/2015 GIS COMMENTS 08/13/2015: Addresses will be assigned by the GIS Department after the plans have met final approval through Development Review and are recorded with the City. Response — Acknowledged. Comment Number: 3 Comment Originated: 08/13/2015 GIS COMMENTS 08/13/2015: Projects with three or more tenant units require the Unit Level Addressing form to be completed and submitted to the GIS Department once plans have met final approval through Development Review and are recorded with the City. This can occur anytime during construction, but before any utilities or address signs are installed. All addressing will be determined by the GIS Department and submitted to Poudre Fire Authority, USPS, Building Services, and Fort Collins Utilities.. Failure to contact GIS and determining addresses through other means may result in address changes. The Unit Level Addressing form can be obtained by contacting the GIS office at gis@fcgov.com or (970) 416-2483. Response — Acknowledged. Contact: Russell Hovland, 970-416-2341, rhovland cgov.com Topic: Building Insp Plan Review Comment Number: 1 Comment Originated: 07/24/2015 07/24/2015: Building Permit Pre -Submittal Meeting: Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 Intemational Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code ([PC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com web page to view them. Accessibility: State, Law CRS 9-5 & ICCIANSI A117.1-2009. Snow Load Live Load: 30 PSF 1 Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load:100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi -family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial chapter. City of Fort Collins Building Services Plan Review 416-2341 Response — Acknowledged. Department: Light And Power Contact: Luke Unruh, 9704162724, lunruh@fcgov.com Topic: General Comment Number: 6 Comment Originated: 1210812015 Street trees will need to be adjusted based on the location of the streetlights. Forty feet of clearance to the streetlight will need to be maintained by shade trees and fifteen feet by ornamental trees. Response — Required spacing provided Department: Outside Agencies Contact: Bob Rulli, Century Link, Topic: General Comment Number: Comment Originated: 07/24/2015 CENTURY LINK 07/24/2015: No issues here. Developer/Building to work with Century Link as needs dictate. I can work with them on specifics (MP at property edge, entrance conduits, backboard space etc. Century Link has no facilities in the ROW around this block so we will have a build out to reach property edge. Also, there are facilities along E Drake (south side) so any relocates necessary to support this build will be at developers expense. Short of that looking forward to the project. Developer can reach out to me for questions as I cover this area. Direct: (970) 490.7503 Cell: (970) 988.2120. robert.rulliecenturylink.com. Response — Acknowledged. Contact: Jason Holland, 970-224-6126, *holland@Lci3ov.com Topic: General Comment Number: 3 Comment Originated: 12/14/2015 12114/2015: Comcast requests a 2 conduit from data room to transformer area. Contact Don Kapperman for details. Response — Acknowledged. Contact: Xcel, , Topic: General Comment Number: 2 Comment Originated: 08/25/2015 XCEL ENERGY 08/25/2015: This will require gas main extension to serve customer. Response — Acknowledged. Department: PFA Contact: Jim Lynxwiler, 970.416-280, llynxwiler@poudre-fire.org Topic: General Comment Number: 7 Comment Originated: 12/01/2015 PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM TEST New buildings require a fire department, emergency communication system evaluation after the core/shell but prior to final build out. For the purposes of this section, fire walls shall not be used to define separate buildings. Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be designed and installed in accordance with criteria established by the Poudre Fire Authority. Poudre Fire Authority Bureau Admin Policy #07-01 Response — Acknowledged. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, ischlarn@ cgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 07/21/2015 11/30/2015: Waiting for Material Submittle FDP 08/03/2015: Waiting for Material Submittle FDP 07/21/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ ischlam .fcgov.com Response — Acknowledged. Contact: Wes Lamarque, 970-416-2418, wlam9rau2@fcg0v.c0m Topic: General Comment Number: 5 12/09/2015: Stormwater is ready for a hearing. Response — Acknowledged. Department: Technical Services Contact: Jeff County, 970-221-6588, jcountv(ai)-fcgov.com Topic: Building Elevations Comment Number: 1 12/08/2015: There are line over text issues. See redlines. 08/04/2015: No comments. Response — Revised Comment Originated: 12/09/2015 Comment Originated: 08104/2015 Topic: Construction Drawings Comment Number: 2 Comment Originated: 08/04/2015 12/08/2015: Please change the legal description to "Lot 1, 3 & Tract A, Warren Federal Credit Union - East Drake". Response — Revised 08/04/2015: Please change the title to "Lot 2, Warren Federal Credit Union - East Drake". Comment Number: 3 Comment Originated: 08/04/2015 12/08/2015: Please show the elevation of benchmark 17-92 to hundredths. 08/04/2015: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # wl DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - X.XX6. Response — Revised Comment Number: 5 Comment Originated: 08/04/2015 12/08/2015: There are line over text issues. See redlines. 08/04/2015: There are line over text issues. See redlines. Response — Revised Topic: Landscape Plans Comment Number: 13 Comment Originated: 12/08/2015 12/08/2015: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Response — Revised Comment Number: 14 Comment Originated: 12/08/2015 12/08/2015: Please add "- East Drake" to the titles. See redlines. Response— Revised Topic: Lighting Plan Comment Number: 8 Comment Originated: 08/04/2015 12/08/2015: There are line over text issues. See redlines. 08/04/2015: No comments. Response — Revised Comment Number: 15 Comment Originated: 12/08/2015 12/08/2015: There are text over text issues. See redlines. Response— Revised Comment Number: 16 Comment Originated: 12/08/2015 12/08/2015: Please add "- East Drake" to the titles. See redlines. Response — Revised Comment Number: 17 Comment Originated: 12/08/2015 12108/2015: Please add "Electrical" to the title of sheet E1.0. See redlines. Response — Revised Topic: Plat Comment Number: 18 Comment Originated: 12/08/2015 12/08/2015: Please change "Engineering Department" in the Notice Of Other Documents statement to "Clerk". See redlines. Response— Revised Topic: Site Plan Comment Number: 10 Comment Originated: 08/04/2015 12/08/2015: Please change the legal description to "Lot 1, 3 & Tract A, Warren Federal Credit Union - East Drake". Response — Revised 08/04/20.15: Please change the legal description to "Lot 2, Warren Federal Credit Union - East Drake". Comment Number: 19 Comment Originated: 12/08/2015 12/08/2015: There are line over text issues. See redlines. Response — Revised Comment Number: 20 Comment Originated: 12/08/2015 12/08/2015: Please add "- East Drake" to the title. See redlines. Response — Revised Department: Traffic Operation Contact: Martina Wilkinson, 970-221-6887, mwilkinsonffcaov.com Topic: General Comment Number: 2 12/01/2015: no new comments Response — Acknowledged Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson(&Jcaov.com Topic: General Comment Originated: 12/01/2015 Comment Number: 1 Comment Originated: 08/04/2015 08/04/2015: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 221-6704 or eolson(&fcgov.com Response — Acknowledged Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamaraue00-fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/04/2015: Please add all water and sewer details during final compliance. Response — Acknowledged Department: Zoning Contact: GaryLopez, 970-416-2338, gloaezc cgov.com Topic: Building Elevations Comment Number: 2 Comment Originated: 11/20/2015: Signage will be approved by separate review requiring sign permit. However, please note the world globe appearing on the building may be considered a sign. If that is the case then the height of the sign cannot be over 7' in height. Currently the sign scales out at 11' in height. Response — Acknowledged. Sign has been removed Topic: Site Plan Comment Number: 1 11/20/2015: Please indicate building dimensions on site plan. Response — Building dimensions have been added. 08/04/2015 11/20/2015 Comment Originated: 11/20/2015 Response — The trash enclosure has been revised to allow walk-in access. Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mragasafficgov.com Topic: General Comment Number: 2 Comment Originated: 08105/2015 08/05/2015: Please label the type of concrete treatment at the comers of Iowa Drive and Limon Drive as well as Illinois Drive and Limon Drive Response — Hardscape enhancement language has been added to the site plan. Comment Number: 3 Comment Originated: 08/05/2015 08/05/2015: It appears that the stairs along Limon Drive at the edge of the ROW line. Please verify that the handrails in these locations will not protrude into the ROW. Response — Stair geometry has been revised to prevent the handrails from protruding into the ROW. Comment Number: 4 Comment Originated: 08/05/2015 08/05/2015: The proposed street cross section for Limon Drive does not meet City standards. A minimum 6' parkway and a 5' sidewalk with a 9' Utility Easement are required for a commercial local street. If an attached sidewalk is desired, the Illinois Drive Cross Section depicted on the Utility Plans for Rigden Farm 8th Filing, The Shops at Rigden Farm can be used. This calls for a 6'-6" walk, 4' tree grate and a 1' additional walk between the tree grate and 6' curb. Response — The crass section for Limon has been revised to meet City standards. Comment Number: 5 Comment Originated: 08/05/2015 08/05/2015: Type III Barricades will be needed on the north end of the sidewalk comer on Illinois and Limon Drive. See redlines. Response — All of the perimeter sidewalks are now proposed to be built Comment Number: 6 Comment Originated: 08/05/2015 08/05/2015: Please clearly define the lot boundaries on the Utility Plans. Response — Lot lines have been revised and are now more square. Comment Number: 7 Comment Originated: 08/05/2015 08/05/2015: It is unclear what is being proposed for this PDP. Please only show details for the Lot 2 improvements on the Utility Plan. Is the storm pipe that extends into Lot 1 a part of this submittal? Will there be off site improvements for the grading required on Lot 1? Will the sidewalk along Illinois Drive be constructed with this proposal? Response — Lot 1 and Lot 2 are now clearly not included in the PDP. The lots will be graded. Comment Number: 8 Comment Originated: 08/05/2015 08/05/2015: There seems to be a discrepancy between the elevations and the Utility/Site Plans. The elevation drawings show a retaining wall for the proposed ramps to run parallel with the sidewalk on Iowa Drive. There is a minimum 2' 3 setback required for walls that run parallel to sidewalks. Response — 2' setback has been provided between the walls and the sidewalk. Comment Number: 10 Comment Originated: 08/06/2015 08/06/2015: Utility Plans show 4.5' wide sidewalks along Iowa Drive. The minimum sidewalk width for a commercial local street is 5'. Response — A 5' sidewalk has been provided. Contact: Sheri Langenberger, 970-221-6573, slanoenbergerftgov.com Topic: General Comment Number: 9 Comment Originated: 08/05/2015 08/05/2015: The project owes an additional $197.50 for the PDP TDRF. It looks like the project did not include the entire area being platted within the calculations. Response — Additional fees have been provided with the resubmittal. Contact: Tom Knostman, tknostman&cgov.com Topic: General Comment Number: 1 Comment Originated: 08/0412015 FROM STREETS DEPARTMENT 08/04/2015: Need to see civil drawings for ROW improvements. Department: Environmental Planning Contact: Kelly Kimple, kkimple ccov.com Topic: General Comment Number: Comment Originated: 08/04/2015 08/04/2015: Our city has an established identity as a forward -thinking community that cares about the quality of life it offers its citizens and has many sustainability programs and goals that may benefit your project. Of particular interest may be the: • ClimateWise program: http://www.fcgov.com/climatewise/ • Zero Waste Plan and the Waste Reduction and Recycling Assistance Program (WRAP): http://www.fcgov.com/recyclinglpdf/_20120404_WRAP_ProgramOverview.pdf, contact Caroline Mitchell at 970-221-6288 or cmtichell@fcgov.com • Green Building and the Climate Action Plan: http:/twww.fcgov.com/enviro/green-building.php, contact Tony Raeker at 970- 416-4238 or traeker@fcgov.com • Nature in the City Strategic Plan: http://www.fcgov.com/planning/natureinthecity/?key=advanceplanning/natureinthecity/, contact Justin Scharton at 970-221-6213 4 or jscharton@fcgov.com Please consider the City's sustainability goals and ways for your development to engage with these efforts. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchanang&aov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 08104/2015 08/04/2015: Use the newly developed project and landscape notes on the project plans. These notes are available from the City Planner. Response — Revised Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: The final landscape plan will need to identify all trees and landscape plants by direct labeling them on the plan. Street trees should be selected from the City of Fort Collins street tree list. Response — Plant callouts will be provided on the final landscape plan. Comment Number: 3 Comment Originated: 08/04/2015 08/04/2015: Skymaster English oak is no longer in nursery production. Due to likely availability problems use another canopy shade tree in its place. Response — Acknowledged. Comment Number: 4 Comment Originated: 08/04/2015 08/04/2015: If there are existing trees on site schedule an on -site meeting with the City Forester to obtain tree inventory information that is required on the plans. Response — There are no existing trees on site. Comment Number: .5 Comment Originated: 08/04/2015 08/04/2015: Is it possible to increase the planting area where trees are shown along Limon Drive by a foot to 5 feet wide to provide a little more room for the trees. Response — The tree law along Limn drive averages 5.5' with the latest plan. Department: Internal Services Contact: Russell Hovland, 970-416-2341, rhovlandWcgov.com Topic: Building Insp Plan Review Comment Number: 1 Comment Originated: 07/24/2015 07/24/2015: Building Permit Pre -Submittal Meeting: Pre -Submittal meetings are offered to assist the designer/builder by assuring, 5 early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amended by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com web page to view them. Accessibility: State Law CRS 9-5 & ICC/ANSI Al 17.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load:100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi -family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi -family 4 stories and taller: 2012 IECC commercial chapter. City of Fort Collins Building Services Plan Review 416-2341 Response — Acknowledged Department: Light And Power Contact: Luke Unruh, 9704162724, Iunruhb-fcaov.com Topic: General Comment Number: 1 Comment Originated: 08/04/2015 08/04/2015: Light and Power has electric facilities on the south side of Drake Rd that could be utilized to provide power to the proposed site. Response — Acknowledged s Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: Please provide a one line diagram and a C-1 form to Light and Power Engineering. The C-1 form can be found at: http://zeus fimov com/uols-procedurestfiles/Encl ikiWl(Pdfs/C/C-1 Form.adf Response — One fine diagram will be provided. Comment Number: 3 Comment Originated: 08/04/2015 08/04/2015: d.) Contact Light and Power Engineering to coordinate the transformer and electric meter locations, please show the locations on the utility plans. Transformer must be within 10' of an asphalt/concrete surface. Pay close attention to the transformer clearances in the Electric Construction Policies, Practices & Procedures. Response — Transformer has been shown on the site and utility plans. Comment Number: 4 Comment Originated: 08/04/2015 08/04/2015: e.) Please contact Luke Unruh at Light & Power Engineering if you have any questions at 970.416-2724. Please reference our policies, development charge processes, and use our fee estimator at http:/twww.ftov.com/ublftk,-Ausiness/builders-and-developers Response — Acknowledged Comment Number: 5 Comment Originated: 08/04/2015 08/04/2015: Development and capacity charges will apply at owner's expense. Response — Acknowledged Department: Outside Agencies Contact: Bob Rulli, Century Link, Topic: General Comment Number: Comment Originated: 07/24/2015 07/24/2015: No issues here. Developer/Building to work with Century Link as needs dictate. I can work with them on specifics (MP at property edge, entrance conduits, backboard space etc. Century Link has no facilities in the ROW around this block so we will have a build out to reach property edge. Also, there are facilities along E Drake (south side) so any relocates necessary to support this build will be at developers expense. Short of that looking forward to the project. Developer can reach out to me for questions as I cover this area. Direct: (970) 490.7503 Cell: (970) 988.2120. robert.rulligbcenturvlink.com. Response — Acknowledged 7 Department: PFA Contact: Jim Lynxwiler, 970416-2869, 11ynxwiler0boudre-fire.ore Topic: General Comment Number: 1 Comment Originated: 07131/2015 07/31/2015: WATER SUPPLY Minimum water supply requirements have been met with the existing utility infrastructure available in the area. Nothing further required. Response — Acknowledged Comment Number: 2 Comment Originated: 07/31/2015 07/31/2015: GENERAL FIRE ACCESS Fire access is required to within 150' of all exterior portions of the ground floor. This minimum fire access requirement has not been met with the site plan, however as the building will be equipped with an automatic sprinkler system, the 52 out of access condition is permitted. Response — Acknowledged Comment Number: 3 Comment Originated: 07/31/2015 07/31/2015: BUILDINGS EXCEEDING THREE STORIES OR 30 FEET IN HEIGHT Minimum aerial access requirements have not been met as per code language provided below. In circumstances when aerial apparatus access cannot be met due to site constraints, upgraded building design and systems may allow for alternative means of compliance. Further discussion would be needed. AERIAL FIRE APPARATUS ACCESS ROADS - WHERE REQUIRED > IFC D105.1: Where the vertical distance between the grade plane and the highest roof surface exceeds 30 feet, approved aerial fire apparatus access roads shall be provided. For purposes of this section, the highest roof surface shall be determined by measurement to the eave of a pitched roof, the intersection of the roof to the exterior wall, or the top of parapet walls, whichever is greater. AERIAL FIRE APPARATUS ACCESS ROADS - WIDTH > IFC D105.2; FCLUC 3.6.2(B)2006; and Local Amendments: Aerial fire apparatus access roads shall have a minimum unobstructed width of 30 feet, exclusive of shoulders, in the immediate vicinity of the building or portion thereof. AERIAL FIRE APPARATUS ACCESS ROADS - PROXIMITY TO BUILDING > IFC D105.3: At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. Response — Building is only one story now (no second floor) and is 23' high except for fireplace/sign wall element that is 36' high. 8 Comment Number: 4 Comment Originated: 07/31/2015 07/31/2015: PARAPET HEIGHT From submitted materials, it appears the parapet height above the roof line will be 5'. In order to allow firefighters access on and off the roof during ladder truck operations, the parapet height would need to be somewhat reduced in all or some portions, unless alternative means of gaining roof access have been approved (See comment no. 4 above). Response — Most parapets are 4' high now. Comment Number: 5 Comment Originated: 07/31/2015 07/31/2015: FDC > IFC 912.2: Fire Department Connections shall be installed in accordance with NFPA standards. Fire department connections shall be located on the street side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access. The location of the FDC shall be approved by the fire department. Response — Acknowledged. We are planning on locating FDC on east elevation accessed from Iowa Drive. Comment Number: 6 Comment Originated: 07/31/2015 07/31/2015: KEY BOXES REQUIRED 2012 IFC 506.1 and Poudre Fire Authority Bureau Policy 88-20: Poudre Fire Authority requires at least one key box ('Knox Box") to be mounted in an approved, exterior location (or locations) on every new or existing building equipped with a required fire sprinkler or fire alarm system. The box shall be positioned 3 to 7 feet above finished floor and within 10 feet of the front door, or closest door to the fire alarm panel. Exception can be made by the PFA if it is more logical to have the box located somewhere else on the structure Response — Acknowledged Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-293Z 'schiam@Mov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 07/21/2015 08/03/2015: Waiting for Material Submttle FDP 07/21/2015: The site disturbs more than 10,000 sq-ft, therefore Erosion and Sediment Control Materials need to be submitted for FDP. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ ischlam( fcaov.com Response — Acknowledged Contact: Wes Lamarque, 970-416-2418, wlamarauMfcgov.com Topic: General Comment Number: 2 Comment Originated: 08/04/2015 08/04/2015: Please compare the flows for each sub-bsin as well. The flow to the inlet in Iowa Drive is proposed to increase. Please verify the inlet and storm 9