HomeMy WebLinkAboutCRAFTS RESUB 412 EAST PITKIN - Filed CS-COMMENT SHEETS - 2016-06-02iiiiPROJECT
Citvof Fort Collins COMMENT SHEET
Current Planning
DATE: July 18, 2006
TO: Engineering Pavement
RECEIVED
JUL 18 2006
PROJECT PLANNER: Shelby Sommer
#20-06 412 E. Pitkin Change of Use PDP — Type II
Please return all comments to the project planner no later than the staff
review meeting:
August 9, 2006
Note -.Please identifyyour redlines for future reference
7 No Problems
❑ Problems or Concerns (see below, attached, or DMS)
Name (le a print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _Site _Drainage Report _Other
Utility Redline Utility Landscape `" °tutCAN"
Response to Conceptual Review Comments
412 E Pitkin PDP
COMMENTS:
1. Jenny Nuckois of the Zoning Department had the following comments:
A. Changes of use of this sort are permitted in the NCM District, subject to a Type 2
(Administrative) Review and Public Hearing, due to the fact that structural alterations are
proposed to the existing building.
RESPONSE: We are submitting the appropriate matmWs and schedulina a hearing with the
Planning and Zoning Board.
B. Minimum side yard setback is five feet, and minimum rear yard setback is five feet from
existing alleys.
RESPONSE: Acknowledged
C. For the proposed two units with two bedrooms each, a minimum of four off-street parking
spaces are required. The existing drive at the side of the house will count as one parking
space, and the drive must extend beyond the font of the house since parking spaces
cannot be in the front yard. The other three parking spaces will need to be accessed from
the alley. Garage spaces will count towards the parking requirement as long as they are
made available to dwelling unit occupants at no additional rental or purchase cost.
RESPONSE: Four off street narking soaces will be orovided at no additlonal chame
2. Mark Virata of the Engineering Department had the following comments:
A. The Transportation Development Review Fee will apply to this project.
RESPONSE: Acknowledaed. See attached.
B. Street Oversizing fees may apply to this development.
RESPONSE: Street oversiz-ina fees have been waived by Matt Baker.
C. A Transportation Impact Study (TIS) may be required but will likely be waived for this
project.
RESPONSE: A TIS for this project was waived per Eric Bracke.
D. Alley improvements are required per Section 3.6.2(J)(2) of the Land Use Code. This
involves the design and construction of the alley from this property to the nearest street
(most likely Whedbee SQ.
RESPONSE: We are seeking a modification to this standard
E. Utility Plans, a Development Construction Permit (DCP) and a Development Agreement
(DA) may be required..
RESPONSE: It is our understandina that these items will only be required if the modification to
alley improvements sought is not granted.
F. Any public improvements must be built according to Larimer County Urban Area Street
Standards (LUCASS).
RESPONSE: Acknowledged.
G. Damaged curb, gutter and sidewalk existing prior to construction, as well as streets,
sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this
project, shall be replaced or restored in like kind at the Developer's expense prior to the
acceptance of completed improvements and/or prior to the issuance of the first Certificate
of Occupancy.
RESPONSE: Acknowledoed
H. Applicant is responsible for undergrounding any existing overhead utilities.
RESPONSE: Acknowledged
3. Rob Irish, of Light and Power, had the following comments:
A. The existing service may be sufficient If a separate meter is needed, development
charges will apply.
RESPONSE: Acknowledged.
4. Glen Schlueter of Storrnwater Utility had the following comments::
A. This site is in the Spring Creek drainage basin. The city wide development fee is
$3,070/acre which is it is subject to the runoff coefficient reduction. This fee is to be paid
at the time the building permit is issued.
RESPONSE: Acknowledged
B. If there is an increase in imperviousness greater than 1000 square feet a drainage and
erosion control report and construction plans are required and they must be prepared by a
Professional Engineer registered in Colorado. A grading plan is required when there is
between 1000 and 350 square feet of new imperviousness, but no drainage study. There
are no requirements for less than 350 square feet.
RESPONSE: Imperviousness will increase by less than 350 square feet. This is documented
on the Site Plan.
C. Onsite detention is required with a 2 year historic release rate for water quantity and
extended detention is required for water quality treatment. These are required if there is
an increase in imperviousness greater than 1000 square feet. If there is less than 1000
but more than 350 square feet of new imperviousness a site grading plan is all that is
required.
RESPONSE: Acknowledged. See 4-B.
D. There are storm sewers in Pitkin St and Whedbee St. if a lower outfall is needed,
otherwise the site can drain Into the street
RESPONSE: Acknowledged
E. It is important to document all impervious areas that are to be removed to show that the
net difference is less than a 1000 square feet of new imperviousness. A letter and sketch
documenting imperviousness on the site is needed with the submittal and it can be
prepared by the applicant or their architect instead of a registered engineer.
RESPONSE: Admowledned. See Site Plan.
5. Roger Buffington, of Water / Wastewater, had the following comments:
A. Development fees and water rights for the additional unit will be due at time of building
permit.
RESPONSE: Acknowledged,
6. David Averill, of Transportation Planning, had the following comments:
A. A 4 foot wide walkway should be provided to the basement entrance from the street
sidewalk.
RESPONSE: David Averill said a 3 foot wide walkway from the street would be aawtable
B. A walkway should be provided from the rear parking spaces to the rear building entrance.
RESPONSE: Acknowledged.
7. Doug Moore, of Natural Resources, had the following comments:
A. Consider using native plants and grass to help to reduce the amount of water needed for
landscaping.
RESPONSE: Acknowledged.
B. If tree removal is proposed, please contact Tim Buchanan, City Forester at (970) 221-
6361 to see if removal of existing bees will be allowed and if mitigation will be required.
RESPONSE: Acknowledged.
8. Cade Dann, of Poudre Fire Authority, had the following comments:
A. The new address will be 412E (Basement) Pitkin St. and must be
displayed with 6" letters visible from Pitkin St.
RESPONSE: Acknowledged
B. A fire hydrant must be located within 300 feet of the site and be able to
provide 1000 gallons per minute at 20 psi.
RESPONSE: There is a fire hydrant within 300' of the property.
C. Egress windows are required in the basement.
RESPONSE: Acknowledged.
Request for Modification
412 E Pitkin PDP
Overview:
Proposed are a change of use in the NCM Zone District from a single-family dwelling to a two-
family residence and a 424 square foot addition to the North side of the existing house.
Modification Request - Section 3.6.2-J(2):
Section 3.6.2-J (2) of the Fort Collins Land Use Code states that "All public alleys shall be
constructed in conformance with the Larimer County Urban Area Street Standards as adopted by the City
Council by ordinance or resolution, except those public alleys within the N-C-L, N-C-M and N-C-B zone
districts that do not abut commercially zoned properties and that provide access only for carriage houses
and habitable accessory buildings as such terns are described in Article 4. Dead-end alleys shall not be
allowed"
Requested Modification:
The 412 E Pitkin PDP will result in a situation exactly the same as the alley/carriage house
exception in the Code, with the lone exception that the additional residential unit is attached. The tenant
entrance will face the alley, where parking will be provided in an existing garage and on a new slab. We are
requesting that alley improvements be waived for this project because of the similarity to the intent of the
Code where it relates to a detached alley house.
Modification Review Procedures — Section 2.8.2 (H)
We are requesting this modification in accordance with Section 2.8.2 (H) which states that the
":..granting of the modification would not be detrimental to the public good..." and that "the plan as
submitted will not diverge from the standards of the Land Use Code ... except in a nominal, inconsequential
way when considered from the perspective of the entire development plan, and will continue to advance the
purposes of the Land Use Code as contained in Section 1.2.2 "
Findings:
Per Section 2.8.2, any finding made "shall, be supported by specific findings showing how the plali,
as submitted, meets the requirements and criteria" of the Modification Review Criteria as stated in T.9.2(M
as follows:
1) The granting of the requested modification would not be detrimental to the public
good because the modification would result in the alley remaining the same as it
exists and because attached residential units have no different impact than detached
residential units provided that access characteristics remain the same.
2) The plan as submitted will not diverge substantially from the standards of the Land
Use Code because the nature and impact of the project will be exactly that of an alley
or carriage house.
STAFF PROJECT REVIEW
City of Fort Collins
Date: 08/23/2006
`fl2C= tp rtQ
RESPONSE TO COMMENTS:
ISSUES:
Department: Current Planning Issue Contact: Shelby Sommer
Topic: Elevations
Number:17 Created: 8/4/2006
[8/4/06] It would be helpful if you could identify what is existing vs. what is proposed on the building
elevations (see redlines).
RESPONSE: See revised Elevations.
Topic: General
Number. 4 Created: 7121/2006
[7/21/06] Don Kapperman (Comcast): No utility easement is shown in the alley. Please revise plans to
show this easement, or dedicate a utility easement if none exists.
RESPONSE: An 8' utility easement will be dedicated and shown on the Site Plan. See attached
document
Number. 5 Created: 7/28/2006
[7/28/06] Bonnie Ham (Post Office): Developer must provide adequate mail receptacles on front of
house.
RESPONSE: Two mail receptacles (412 Pitkin & 412-B Pitkin) will be provided.
Number. 6 Created: 8/2/M
[812/06] Rick Lee (Building Inspection): Please find attached the various odes that the Fort Collins
Building Department will enforce. Be aware that multiple family dwellings have some special
construction requirements. The most challenging is going to be the required one -hour floor / ceiling
tenant separation. This may mean providing a new 5V gypsum board ceiling supported by hat
channels throughout and surface mounted light fixtures. Another challenging component is that the
interior air cannot be shared and that independent heat sources shall be provided.
RESPONSE: Aclmowledged Developer is aware of the applicable codes and will adhere to them.
Page 1
Number: 21 Created: 8/10/2006
[8110/06] Karen McWilliams (Historic Preservation): This proposal went through the
Demolition/Alteration Review process (required because the residence is 50+ years old). The property
was determined to not qualify to be individually eligible for landmark designation, due to previous
alterations to the building (notably the front porch). Because the building is not individually eligible,
there is no additional historic preservation review - - the standards in LUC Section 3.4.7 (Historic and
Cultural Resources) do not apply, nor would there be a hearing in front of the LPC.
RESPONSE: Acknowledged.
Number. 22 Created: 8/10/2006
[8110/06] JR Wilson (Technical Services): No concerns.
RESPONSE: Acknowledged.
Topic: Landscaping
Number.15 Created: 8/4/2006
[8/4/06] Please show any existing street trees in the parkway strip between the sidewalk and street.
RESPONSE: See revised Site Plan,
Topic: Lighting
Number:18 Created: 8/4/2006
[8l4/06] There seems to be a lot of motion sensor lighting that could potentially affect neighboring
properties. Can they be positioned so that they do not spill over onto neighboring properties? Will they
have an override switch to tam them off?
RESPONSE: Proposed motion sensor lighting has been reduced on the revised Site Plan and will be
equipped with an override switch Also landscape lighting will be dose to the -ground. See revised Site
Plan for details.
Topic: Site Plan
Number:16 Created: 8/4/2006
[8/4/06] Please show proposed dimensions for new addition, porch, garage and concrete slab. Also,
please include floor area calculations for what is existing and what is proposed. Per Division 4.7 (D)(1)
Minimum lot area is 2 times the total floor area of the buildings, and per Division 4.7(D)(5) lots are
subject to a minimum floor area ratio (FAR) of .33 on the rear 50 percent of the lot. Please confirm
these calculations in your comment response letter or on the site plan.
RESPONSE: See revised Site Plan.
Page 2
Department: Engineering Issue Contact: Randy Maizland
Topic: General
Number: 7 Created: 8/4/2006
[8/4106] Show any new proposed utility connections or relocations of existing services on the Site Plan
— water, sewer, power etc...
RESPONSE: No new utilities other than a separate electric meter will be required for this project. The
existing electric meter will be relocated. See revised Site Plan for details.
Number. 8 Created: 8/4006
[8/4/06] An 8 foot wide utility easement must be dedicated behind the alley right-of-way along the alley
frontage of the property. This dedication can be recorded by separate instrument. The document shall
contain a written legal description and exhibit map prepared by a CO licensed surveyor. A copy of the
standard easement dedication language is included with the red -lines. Please show and label the 8 foot
utility easement with a dashed line on the site Plan. A Transportation Development Review Fee of $250
must be submitted with the easement document.
RESPONSE: An 8' utility easement will be dedicated and shown on the Site Plan. See attached
document.
Number 9 Created: 8/4/2006
[8/4/06] Please show surface drainage patterns around the new building additions and all new
concrete and flagstone flatwork with arrows. All surface drainage shall be conveyed toward Pitkin or the
alley without crossing adjoining property lines.
RESPONSE: See revised Site Plan.
Number 10 Created: 8/4/2006
[814/06] Please label concrete patios as existing or proposed on the Site Plan showing surface
drainage patterns with arrows.
RESPONSE: See revised Site Plan
Number 11 Created: 8/4/2006
[8/4/06] Add the following note to the Site Plan: Any damage sidewalk, curb & gutter existing or
damaged during construction shall be replaced at the direction of the City Engineering Inspector prior
to final acceptance by the City and issuance of a Certificate of Occupancy.
RESPONSE: Acknowledged. See revised Site Plan.
Number 12 Created: 8/4/2006
[8/4/06] The request for a modification to the Land Use Code Section 3.6.2-J(2) is supported by the
Transportation Development Review staff.
RESPONSE: Acknowledged.
Page 3
Number:13 Created: 8/4/2006
[8/4/06] Add a Vicinity Map to the Site Plan showing the project location with respect to major arterial
cross streets.
RESPONSE: See revised Site Plan.
Department: Light & Power Issue Contact: Doug Martine
Topic: Electric Utility
Number:1 Created: 7/19/2006
[7/19/06] City ordinances require separate dwelling units to have separate electric meters. Therefore,
the owner will need to modify the electric metering system to provide two meters (one for existing
dwelling, and a second for the basement dwelling). Additional electric development charges as well as
possible electric system modification charges will apply. Contact Light & Power engineering at 221-
6700.
RESPONSE: Acknowledged. See revised Site Plan for details.
Department: Natural Resources
Topic: General
Number: 2
[7/19/06] No issues.
' RESPONSE: Acknowledged.
Issue Contact: Doug Moore
Created: 7/19/2006
Department: PFA Issue Contact: Carle Dann
Topic: Fire
Number:19 Created: 8/8/2006
[8/8/06] Applicant needs to meet PFA requirements from conceptual review regarding addressing,
water supply and egress windows (applicant acknowledged comments in response letter), in addition to
Building Department requirements related to fire safety.
RESPONSE: 4040 egress windows will be provided in the new basement bedrooms. A fire hydrant is
located at the NW comer of Pitkin and Whedbee, approximately 200' from the center of the property.
Additionally, the address of the proposed new dwelling unit will be displayed as 412-B in 6" letters
visible from Pitkin Street.
Department: Transportation Planning
Topic: Fire
Number: 20
[8/9/06] No comments or concerns.
RESPONSE: Acknowledged.
Issue Contact: David Averill
Created: 8/9/2006
Page 4
Department: Stormwater-Water-Wastewaterlssue Contact: Roger Buffington
Topic: General
Number:14 Created: 8/4/2006
[8/4/06] No comments.
RESPONSE: Acknowledged.
Department: Zoning Issue Contact: Jenny Nuckols
Topic: General
Number. 3 Created: 7/19/2006
[7/19/06] no comments
RESPONSE: Acknowledged.
Please revise your plans and make an appointment with Sandy Lindell at 221-6750 when you are
ready to submit your PDP revisions. I have attached a revision routing sheet that indicates how many
of each item to submit for further review. Please be sure and return all of your redlined plans when
you re -sit.
, - # any questions regarding these issues or any other issues related to this project, please feel
to �dOv a at (970) 221-6750.
fly,
Shelby Sommer
Associate City Planner
Page 5
Straightedge Drafting & Design 8/23/20M
4115 Terry Lake Road
Fort Collins, CO 80524
RE: 412 E PITKIN PDP / UTILITY EASEMENT DEDICATION
Staff:
Staff Project Review notes from 8/10/2006 indicate that an 8' utility easement needs to be
dedicated behind the alley ROW and shown on the Site Plan for 412 E Pitkin. We are requesting a Type II
Daring for September without having yet dedicated this easement with the understanding that said
easement will be recorded before a permit can be issued.
Thank You,
Phillip Sand
Straightedge Drafting & Design
M
STAFF PROJECT REVIEW
City of Fort Collins
PHILLIP SAND Date: 09/08/2006
STRAIGHTEDGE DRAFTING AND DESIGN
4115 TERRY LAKE ROAD
FORT COLLINS, CO 80524
Staff has reviewed your submittal for 412 E. PITKIN CHANGE OF USE PDP -TYPE
II, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Shelby Sommer
Topic: General
Number: 25 Created: 9/6/2006
[9/6/06] This project has been scheduled for the September 21 Planning and Zoning
Board meeting to be held at 6 pm in the City Council Chambers. This project has
been placed on the Consent Agenda, but may be pulled off for discussion by any
member of the Board or the public. Please let me know if you have any questions
about the P&Z hearing. A draft version of the staff report is available for you if you
would like a copy.
If the project is approved at the P&Z hearing, you must wait 14 days for an appeal
period, in which the decision may be appealed. If the project is approved, and after
the appeal period passes, you may submit final mylars. A Final Plan Transportation
Development Review Fee of $1000 will be due when the final plan/mylars are
submitted.
Department: Engineering Issue Contact: Randy Maizland
Topic: General
Number: 8 Created: 8/4/2006
[8/29/06] Please graphically show the limits of the utility easement on the Site Plan
with a dashed line or hatch filled. The easement document and associated review
fee must be submitted and approved, ready to record, prior to final plan approval.
OK to schedule for a hearing prior to the easement submital.
[8/4/06] An 8 foot wide utility easement must be dedicated behind the alley right-of-
way along the alley frontage of the property. This dedication can be recorded by
separate instrument. The document shall contain a written legal description and
exhibit map prepared by a CO licensed surveyor. A copy of the standard easement
dedication language is included with the red -lines. Please show and label the 8 foot
utility easement with a dashed line on the site Plan. A Transportation Development
Review Fee of $250 must be submitted with the easement document.
Department: Stormwater-Water-Wastewater
Topic: Lot Drainage
Number: 23
Page 1
Issue Contact: Basil Harridan
Created: 8/11 /2006
[9/8/06] Please add a note to the site plan stating that no drainage from this site will
be directed at the neighboring properties.
Be sure and return all of your redlined plans when you submit your mylars.
If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at (970) 221-6750.
Sincerely,
3u b( �
ShelbySorrtmer
Associate City Planner
Page 2