HomeMy WebLinkAboutWESTSIDE ADDITION BLOCK 292 LOT 19 224 WOOD STREET - Filed CS-COMMENT SHEETS - 2016-06-02City of
F6rt Collins
Current Planning
PO Box 580
Fart Collins, CO 80522-0580
Far: 970-224-61 i4
DATE: June 17, 2010
TO: Engineering
FINAL PLAN
COMMENT SHEET
PROJECT PLANNER: Emma McArdle
# 8-10IA 224 WOOD STREET
Please return all comments to the project planner no later than
the staff review meeting:
June 30, 2010
Note -.Please identify your redlines for future reference
No Problems
Problems or Concerns (see below, attached, or DMS)
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
_Plat _Site _Drainage Report _Other
_ Utility _Redline Utility _Landscape
(5/19/10] Please add the following note:
"General Construction Notes #1 through 18, 20 through 39, and 42 through 46 as listed in
Appendix E-1 of the Larimer County Urban Area Street Standards (LCUASS) shall apply
and be followed for this project."
"The Construction Notes under subsection Street Improvement Notes and Traffic Signing,
and Pavement Marking Construction Notes in Appendix E-2 of the Larimer County Urban
Area Street Standards (LCUASS) shall apply and be followed by this project as applicable.
(Plans were revised accordingly)
Number: 24 Created: 5/19/2010
[5/19/10] Please add the following details: 701 (or 702 depending on whether Wood St has
Rollover or VC), 706, 1601, 1602.
(Plans were revised accordingly)
Page 2
Fort Collins STAFF PROJECT REVIEW
BRYAN SOTH Date: 4/28/2010
HIGHCRAFT BUILDERS
429 S. HOWES ST
FORT COLLINS, CO 80521
Staff has reviewed your submittal for 224 WOOD STREET - ACCESSORY BUILDING WITH
HABITABLE SPACE PDP - TYPE I, and we offer the following comments:
ISSUES:
Department: Advance Planning Issue Contact: Emma McArdle
Topic: Modification of Standards
Number: 14 Created: 4/28/2010
[4/28/10] The modification of standards request needs to identify which criteria the request
is meeting in 2.8.2 of the LUC, there are 4 criteria, please site the once you are using, it
would most likely be the criteria describing hardship.
(The modification is requested for reasons of "exceptional physical conditions or
other extraordinary and exceptional situations... ")
Topic: Site Plan
Number: 15 Created: 4/28/2010
[4/28/10] Please add standard signature blocks to the site plan, I can give you an example
of what these look like and say.
(Acknowledged)
Number: 16 Created: 4/28/2010
(4/28/10] Please start off with Title on top - "224 Wood Street - Accessory Building with
Habitable Space," the legal description should follow below.
(Acknowledged)
Number: 17 Created: 4/28/2010
[4/28/10] Please add/change the following on the Site Plan:
- change scale to engineer's scale,
- show height of building,
- add 1/2 lot line for FAR reference,
- show full ROW and dimensions (including separated out sidewalk, parkway, curbline),
- add existing and proposed utility lines (water, sewer, electric),
- clarify easements,
- proposed impervious surface in s.f.
- change SYSB to spell out Side Yard Setback, FYSB, etc.,
- change gravel to paved surface used,
- add lines of neighboring property lines to show some context,
- are there existing trees in the parkway? If so please show them.
(Acknowledged)
Number: 18 Created: 4/28/2010
[4/28/10] Please add the following notes to the site plan:
Page 1
Z aft"d
OI,OZ/9Z/b :pa;eajo £ :aagwnN
�f;iaoy;nd eagd :oidol
uuea alaeo :;ae;uoo anssl VAd :;uewueda(3
{pa;eoo/ai aq o; paau;ou saop jauuo,;sueal •asnoy woaj awoo jym jaMod}
-Aldde Ilion sac; Iewaou pue jauuolsuej;
Bul;slxa ay} wa; awoo ll!M GOINas `papeau si jannod leuoi;lppe;I •s;uewwoo jeq:pn; ou
ane4 ann 'asnoy a4; wa; uaMe; sl aolnias;I asuadxa d�� ;e auop aq IIIM s14; `(;uawasea
a4;;o epls;no peoeld seen;! aM!I sMool;!) pa;eoolaj aq o; spaau aawjojsuea; a4;;I IOULZ/,l
060Z/LZ/b :pa;eaJO v :aagwnN
on6e a /eaauao :aidol
1 W ;aue� :;ae;uo� anssl aannod V ;461-1 :;uew:pedaa
{paBpaIMou.Yob}
sueid adeospuel pue a;ls 'A;!I!;n 94; a;eulpa000 pue ;as ueld Al!lgn
943 uo umogs aq;snw;e4; uol;ewjojul pailnbai 94; jo lie ao; ssdflol aas aseald 106/LZ/V1
OI,OZ/LZ/V :pa;eaao £ 6 :jagwnN
{paBpaIMouVod}
1uawase3 Ailpn ,6 pasodoad Jo IUawase3 Apmn ,6 Bu11slx3 :aidwexe jo3
•Bul;sixe jo pesodoid si ;! p pue sl ;! adA;;egm 4;Inn pelegel eq ;snw s;uawasea Ilb 10I-/LZ/V1
060Z/LZ/17:pa3eajo Zi, aagwnN
{pafipa1Mou-YaW
weld adeospuel ay; uo sai;!gn Ile mo4S [Ol/LZ/t,l
060Z/LZ/ti :pa;eajO I, I, :aagwnN
tpe.gnbai jj AeManup a;aaouoo y;/M
)/o s►;nq oBeureip aoj AeManup IeAeaB pue uoide a)aa3uo3 a jejoid pinoM aauMo)
•paned aq ;snw Rape ay; };o ABM,9niJp a41 IO 4/LZ/til
OI,OZ/LZ/ti :pa;e0aO 01• :jagwnN
{paBpa/Mouvow
s;as ueld mop( uo swat! pajlnbaj lie apnioui pue
le:4!wgns;xou ay; Wm ti3 xipueddy wog;;sllNoa4o pa;aldwoo e;!wgns aseald 10L/LZ/til
0 60Z/LZ/ti :pa;eaJO 6 :jagwnN
{096081MouNad}
,ssv lol 4;Inn aouepa000e ul ;as ueld A3!mn a pwgns aseald IO I,/LZ/Vl
OLOZ/LZ/IP:pa;eaaO a :aagwnN
�(o uesn BuuaautBu3 :o1dol
S :;ae;uo3 onssl BupoeulBu3 wowpedea
{paBpaIMouNad}
•Bulssaippe ain;onj;s pue Alddns aa;em Bul;yBl;ajl;
`ssaooe 910149n AouaBJawa Bulpieft Ajpo4;ny aji3 aapnod;o s;uawaimbaa pal;loads ay;
;caw o; paau II!nn ainioni;s ay; `Ajpo4;nV aji3 ajpnod Aq „Aouedn000 Iei;uaplsaj„ pajap!suoo
si 4o14nn 'am;onj;s tiewpd ay;;o ;ueplsaj a Aq sja:penb Buidaals jo; pasn si ain;oni;s ay;;!
•A;pou;nV aa13 aapnod pue 40 941
Aq nnalnaJ ja4ljn; ;no4;!M ain;n; a4; ui ;lun BuillaMp a se pasn aq ;ou Aew pue ;lun BulllaMp
e ;ou si ;! „'coeds elge;!ge4 4;!nn amion4s AJOSSaooe„ ue pajaplsuoo si ain;ona;s si41
it-
This structure is considered an "accessory structure with habitable space," it is not a
dwelling unit and may not be used as a dwelling unit in the future without further review by
the City and Poudre Fire Authority.
If the structure is used for sleeping quarters by a resident of the primary structure, which is
considered "residential occupancy" by Poudre Fire Authority, the structure will need to meet
the specified requirements of Poudre Fire Authority regarding emergency vehicle access,
firefighting water supply and structure addressing.
(Acknowledged)
Department: Engineering Issue Contact: Susan Joy
Topic: Engineering
Number: 8 Created: 4/27/2010
[4/27/10] Please submit a Utility Plan set in accordance with LCUASS.
(Acknowledged)
Number: 9 Created: 4/27/2010
[4/27/10] Please submit a completed checklist from Appendix E4 with the next submittal
and include all required items on your plan sets.
(Acknowledged)
Number: 10 Created: 4/27/2010
[4/27/10] The driveway off the alley must be paved.
(Owner would prefer a concrete apron and gravel driveway for drainage but is OK
with concrete driveway if required.)
Number: 11 Created: 4/27/2010
[4/27/10] Show all utilities on the landscape plan.
(Acknowledged)
Number: 12 Created: 4/27/2010
[4/27/10] All easements must be labeled with what type it is and if it is proposed or existing.
For example: Existing 9' Utility Easement or Proposed 9' Utility Easement.
(Acknowledged)
Number: 13 Created: 4/27/2010
[4/27/10] Please see LCUASS for all of the required information that must be shown on the
utility plan set and coordinate the utility, site and landscape plans.
(Acknowledged)
Department: Light & Power Issue Contact: Janet McTague
Topic: General
Number: 4 Created: 4/27/2010
[4/27/10] If the transformer needs to be relocated ( it looks like it was placed outside of the
easement), this will be done at L&P expense. If service is taken from the house, we have
no further comments. If additional power is needed, service will come from the existing
transformer and normal fees will apply.
/Power will come from house. Transformer does not need to be relocated.)
Department: PFA
Topic: Fire Authority
Number: 3
Issue Contact: Carle Dann
Created: 4/26/2010
Page 2
If the structure will ever be used as a sleeping area (Residential Occupancy Type), the
following requirements must be met:
WATER SUPPLY
Fire hydrants, where required, must be the type approved by the water district having
jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum
requirements based on type of occupancy. Minimum flow and spacing requirements include:
Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not
further than 400 feet to the building, on 800-foot centers thereafter
These requirements may be modified if buildings are equipped with automatic fire sprinkler
systems.
PLEASE NOTE: In response, to Bryan Soth's question, I don't have flow records for that
area but Roger Buffington from FC Water might. The closest hydrant is at 240 Wood St.
REQUIRED ACCESS
Fire access roads (fire lanes) shall be provided for every facility, building or portion of a
building hereafter constructed or moved into or within the PFA's jurisdiction when any
portion of the facility or any portion of an exterior wall of the first story of the building is
located more than 150 feet from fire apparatus access as measured by an approved route
around the exterior of the building or facility. This fire lane shall be visible by painting and
signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for
approval prior to installation. In addition to the design criteria already contained in relevant
standards and policies, any new fire lane must meet the following general requirements:
❑ Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of
supporting fire apparatus weights. Compacted road base shall be used only for temporary
fire lanes or at construction sites.
❑ Have appropriate maintenance agreements that are legally binding and enforceable.
Be designated on the plat as an Emergency Access Easement.
Maintain the required minimum width of 20 feet throughout the length of the fire lane
(30 feet on at least one long side of the building when the structures is three or more stories
in height).
If the building is equipped throughout with an approved automatic fire -sprinkler system, the
fire code official is authorized to increase the dimension of 150 feet.
PLEASE NOTE: The proposed structure is approximately 165 feet from the edge of Wood
Street. Also, PFA does not "count" alleys as a means of emergency vehicle access.
2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
ADDRESS NUMERALS
Address numerals shall be visible from the street fronting the property, and posted with
minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown
brick are not acceptable). 2006 International Fire Code 505.1
{Acknowledged)
Department: Technical Services
Topic: General
Number: 2
[4/22/10] We have no comments.
Department: Stormwater-Water-Wastewater
Topic: Stormwater
Number: 5
Issue Contact: Jeff County
Created: 4/22/2010
Issue Contact: Wes Lamarque
Created: 4/27/2010
Page 3
.: '5
[4/27/10] Please provide a grading plan for the rear third of the lot per conceptual review
comments. The distance to the south lot line is very minimal. The drainage of this new
structure can not have a negative impact to the property and structure to the south. A
concrete pan may be needed to direct the water to the alley or to the front.
{Drainage will be addressed with gutters and spouts per plan.}
Number: 6 Created: 4/27/2010
[4/27/10] Please direct the downspouts to grassy surfaces for water quality treatment.
(Acknowledged)
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: WaterMastewater
Number: 7 Created: 4/27/2010
[4/27/10] The water and sewer services for the house connect to water and sewer mains in
Wood Street. There are no water/sewer mains in the alley.
(Acknowledged)
Department: Zoning Issue Contact: Gary Lopez
Topic: Zoning
Number: 1 Created: 4/21 /2010
[4/21/10] There is not enough information to conclude this bldg. is 1.5 stories. Interior
elevation drawings and floor plans are required. Per LUC 5.1 Def. Story, half "shall mean a
space under a sloping roof which as the line of intersection of the roof and wall face not
more than three (3) feet above the floor level, and in which space the possible floor area
with head room of five (5) feet or less occupies at least forty (40) percent of the total floor
area of the story directly beneath."
(Acknowledged)
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
Emma McArdle
City Planner
Page 4
[4/27/10] Please provide a grading plan for the rear third of the lot per conceptual review
comments. The distance to the south lot line is very minimal. The drainage of this new
structure can not have a negative impact to the property and structure to the south. A
concrete pan may be needed to direct the water to the alley or to the front.
(Drainage will be addressed with gutters and spouts per plan.)
Number: 6 Created: 4/27/2010
[4/27/10] Please direct the down spouts to grassy surfaces for water quality treatment.
(Acknowledged)
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: Water/Wastewater
Number: 7 Created: 4/27/2010
[4/27/10] The water and sewer services for the house connect to water and sewer mains in
Wood Street. There are no water/sewer mains in the alley.
(Acknowledged)
Department: Zoning Issue Contact: Gary Lopez
Topic: Zoning
Number: 1 Created: 4/21 /2010
[4/21/10] There is not enough information to conclude this bldg. is 1.5 stories. Interior
elevation drawings and floor plans are required. Per LUC 5.1 Def. Story, half "shall mean a
space under a sloping roof which as the line of intersection of the roof and wall face not
more than three (3) feet above the floor level, and in which space the possible floor area
with head room of five (5) feet or less occupies at least forty (40) percent of the total floor
area of the story directly beneath."
{Acknowledged}
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
Emma McArdle
City Planner
Page 4
at yof Project Comments Sheet
F ort Collins
Selected Departments
Department: Engineering
Date: June 15, 2010
Project:
224 WOOD STREET - ACCESSORY BUILDING WITH HABITABLE SPACE
PDP - TYPE I
All comments must be received by Emma McArdle in Advance Planning, no later
than the staff review meeting:
May 21, 2010
Note - Please identify your redlines for future reference
Issue Contact: Susan Joy
Topic: Engineering
Number: 11 Created: 4/27/2010
[5/19/10] 1 was not routed a Landscape plan. I was only given a Site plan. Was this to be a
combined Site and Landscape Plan? If so, please label as such. (Plans were revised
accordingly)
[4/27/10] Show all utilities on the landscape plan. (Plans were revised accordingly)
Number: 19 Created: 5/19/2010
[5/19/10] Please dimension in engineering scale, not architectural. {Plans were revised
accordingly}
Number: 20 Created: 5/19/2010
[5/19/10] Please dimension all sidewalks and parkway along Wood Street. (Plans were
revised accordingly)
Number: 21 Created: 5/19/2010
[5/19/10] Please label the existing curb type on Wood Street. (Plans were revised
accordingly)
Number: 22 Created: 5/19/2010
[5/19/10] Please see Appendix E6 for scanning requirements. The Vicinty map will not
scan. Please change to a one -line map, to scale (1" = 1000-1,500'), without any shading.
(Plans were revised accordingly)
Number: 23
Signature
Created: 5/19/2010
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report Other
Utility Redline Utility Landscape
Page 1
[5/19/10] Please add the following note:
General Construction Notes #1 through 18, 20 through 39, and 42 through 46 as listed in
Appendix E-1 of the Larimer County Urban Area Street Standards (LCUASS) shall apply
and be followed for this project."
"The Construction Notes under subsection Street Improvement Notes and Traffic Signing,
and Pavement Marking Construction Notes in Appendix E-2 of the Larimer County Urban
Area Street Standards (LCUASS) shall apply and be followed by this project as applicable.
{Plans were revised accordingly}
Number: 24 Created: 5/19/2010
[5/19/10] Please add the following details: 701 (or 702 depending on whether Wood St has
Rollover or VC), 706, 1601, 1602.
(Plans were revised accordingly)
Page 2