HomeMy WebLinkAboutWILLOW STREET RESIDENCES - FDP180027 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLAN (4)IRRIGATION LEGEND THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE 1-INCH BACKFLOW PREVENTER INSTALLED BY OTHERS INSIDE OF 'BUILDING A' CENTRAL PLANT ROOM (ROOM 103). THE IRRIGATION CONTRACTOR SHALL FIELD LOCATE A 1-INCH IRRIGATION WATER SERVICE INSTALLED TO THIS APPROXIMATE LOCATION IN LANDSCAPE BED, MAKE CONNECTION AND INSTALL MASTER VALVE AND FLOW SENSOR AS INDICATED, SAME SIZE AS POC. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE. WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN INSIDE OF 'BUILDING A' CENTRAL PLANT ROOM (ROOM 103) . COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. FIELD LOCATE PVC CONDUIT INSTALLED BY OTHERS AND ROUTE CONTROL WIRES TO IRRIGATION CONTROL VALVES. FINAL CONTROLLER LOCATION TO BE APPROVED BY OWNER'S REPRESENTATIVE. IRRIGATION SHOWN OUT OF LANDSCAPED AREA FOR CLARITY ONLY. INSTALL IRRIGATION COMPONENTS WITHIN LANDSCAPED AREA. PLANTER POTS LOCATED ALONG WILLOW STREET FRONTAGE SHALL BE HAND WATERED. TYPICAL ALL PLANTERS. INSTALLATION GENERAL NOTES CONSTRUCTION NOTES 1. THE SYSTEM DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM OF 75 PSI, AT A MAXIMUM DISCHARGE OF 25 GPM AT THE 1-INCH IRRIGATION POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. 2. READ THOROUGHLY AND BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. 3. COORDINATE UTILITY LOCATES ("CALL BEFORE YOU DIG") OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. 4. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS OR GRADE DIFFERENCES EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. IF DISCREPANCIES IN CONSTRUCTION DETAILS, LEGEND, NOTES, OR SPECIFICATIONS ARE DISCOVERED, BRING ALL SUCH OBSTRUCTIONS OR DISCREPANCIES TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE. 5. THE DRAWINGS ARE DIAGRAMMATIC. THEREFORE, THE FOLLOWING SHOULD BE NOTED: A. ALTHOUGH IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY, INSTALL IRRIGATION PIPE AND WIRING IN LANDSCAPED AREAS WHENEVER POSSIBLE. B. TREE AND SHRUB LOCATIONS AS SHOWN ON LANDSCAPE PLANS TAKE PRECEDENCE OVER IRRIGATION EQUIPMENT LOCATIONS. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES. C. USE ONLY STANDARD TEES AND ELBOW FITTINGS. USE OF TEES IN THE BULLNOSE CONFIGURATION, OR USE OF CROSS TYPE FITTINGS IS NOT ALLOWED. 6. PROVIDE THE FOLLOWING COMPONENTS TO THE OWNER PRIOR TO THE COMPLETION OF THE PROJECT: A. TWO (2) OPERATING KEYS FOR EACH TYPE OF MANUALLY OPERATED VALVES. B. TWO (2) OF EACH SERVICING WRENCH OR TOOL NEEDED FOR COMPLETE ACCESS, ADJUSTMENT, AND REPAIR OF ALL ROTARY SPRINKLERS. 7. SELECT NOZZLES FOR SPRAY AND ROTARY SPRINKLERS WITH ARCS WHICH PROVIDE COMPLETE AND ADEQUATE COVERAGE WITH MINIMUM OVERSPRAY FOR THE SITE CONDITIONS. CAREFULLY ADJUST THE RADIUS OF THROW AND TF E E NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DUCTILE IRON NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST DUCTILE IRON TF E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FLOW SENSOR ASSEMBLY ISOLATION GATE VALVE ASSEMBLY QUICK COUPLING VALVE ASSEMBLY REMOTE CONTROL TURF VALVE ASSEMBLY REMOTE CONTROL DRIP VALVE ASSEMBLY SINGLE OUTLET DRIP EMITTER ASSEMBLY DRIP FLUSH CAP ASSEMBLY WALL MOUNT CONTROLLER ASSEMBLY MASTER VALVE ASSEMBLY PROFILE VIEW PLAN VIEW TYPICAL IRRIGATION CONTROLLER GROUNDING ROD OR PLATE INSTALLATION EMITTER SCHEDULE 1 2 3 4 5 6 7 8 9 10 11 IR-501 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: FINAL DEVELOPMENT PLAN APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® PDP 1 04/17/2018 PDP 2 07/17/2018 PDP 3 08/15/2018 P+Z 09/04/2018 FDP 1 10/31/2018 FDP 2 12/12/2018 12/12/2018 As indicated WILLOW STREET RESIDENCES 118014.00 SH EP EP IRRIGATION DETAILS TYPICAL TRENCHING DETAIL TYPICAL SLEEVING DETAIL BUBBLER ASSEMBLY FOR TREES IN GRATES 6-INCH POP UP SPRAY SPRINKLER ASSEMBLY TYPICAL VALVE BOX INSTALLATION 12 13 14 15 16 IR-502 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: FINAL DEVELOPMENT PLAN APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® PDP 1 04/17/2018 PDP 2 07/17/2018 PDP 3 08/15/2018 P+Z 09/04/2018 FDP 1 10/31/2018 FDP 2 12/12/2018 12/12/2018 As indicated WILLOW STREET RESIDENCES 118014.00 SH EP EP IRRIGATION DETAILS F F W ILLOW ST. PINE STREET. PINE STREET. 11 4 " 11 4 " 112" 11 4 " BUILDING A BUILDING B CONTROLLER 120 VAC POWER REQUIRED POC SIZE: 1-INCH PRESSURE: 75 PSI FLOW: 25 GPM 1-INCH IRRIGATION SERVICE BY MECHANICAL. FOR REFERENCE ONLY 1-INCH IRRIGATION BACKFLOW BY MECHANICAL. FOR REFERENCE ONLY 1.5-INCH PVC CONDUIT FOR CONTROL WIRES BY MECHANICAL. FOR REFERENCE ONLY 1 1 4 " A1 2.00 Tree 1" A2 Drip Shrub 1" A3 Drip Shrub 1" A4 13.2 Turf 1" A5 12.2 Turf 1" A6 16.1 Turf 1" A7 Drip Shrub 1" A8 7.80 Turf 1" A9 18.6 Turf 1" A10 Drip Shrub 1" A11 3.00 Tree 1" A F 1.5" 4 4 3 4 4 4 2 1 3" 1.5" 3" 3" 1.5" 1.5" 1.5" 1.5" 3" 2" 1.5" 2" 2" 1.5" 1.5" 2" 2" 1.5" 1.5" 1.5" 1.5" 1.5" 3" 1.5" 1.5" 1.5" 2" 1.5" 1.5" 3" 20' 0 10' 20' 40' N O R T H IR-101 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: FINAL DEVELOPMENT PLAN APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® PDP 1 04/17/2018 PDP 2 07/17/2018 PDP 3 08/15/2018 P+Z 09/04/2018 FDP 1 10/31/2018 FDP 2 12/12/2018 12/12/2018 As indicated WILLOW STREET RESIDENCES 118014.00 SH EP EP IRRIGATION PLAN ARC OF COVERAGE OF EACH ROTARY SPRINKLER TO PROVIDE THE BEST PERFORMANCE. 8. THE IRRIGATION CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF IRRIGATION SLEEVING. SLEEVES ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. PIPE SLEEVES SHALL BE SIZED TWICE THE NOMINAL SIZE OF THE PIPE PASSING THROUGH. 9. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 10. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 11. INSTALL TWO (2) #14 AWG CONTROL WIRES FOR USE AS SPARES. INSTALL SPARE WIRES FROM CONTROLLER LOCATION TO EACH DEAD-END OF MAINLINE. COIL 3 FEET OF WIRE IN VALVE BOX. IRRIGATION PIPE SCHEDULE THE IRRIGATION CONTRACTOR SHALL CONTACT PARRY WEBB WITH WEATHERMATIC FOR CONTROLLER BUNDLE ORDERING AND PRICING ASSISTANCE. PARRY.WEBB@WEATHERMATIC.COM OFFICE: 972-926-2193 MOBILE: 303-638-6268 REMOTE CONTROL DRIP VALVE ASSEMBLY: RAIN BIRD XCZ-PRB-100-COM QUICK COUPLING VALVE ASSEMBLY: RAIN BIRD 5RC ISOLATION GATE VALVE ASSEMBLY: MATCO 514 POINT-OF-CONNECTION ASSEMBLY UNCONNECTED PIPE CROSSING C IRRIGATION CONTROLLER UNIT BUNDLE W/ WEATHER STATION WEATHERMATIC VAR#: 11530 IRRIGATION CONTROL WIRES IN CONDUIT OR WITH WARNING TAPE A1 14 1" INDICATES LATERAL DISCHARGE (GPM) INDICATES VALVE SIZE (INCHES) INDICATES CONTROLLER AND STATION NUMBER INDICATES LANDSCAPE APPLICATION Turf LATERAL PIPE TO SPRINKLERS: 1-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC MAINLINE PIPE: 1 1/2-INCH SIZE UNLESS OTHERWISE INDICATED CLASS 200 PVC LATERAL PIPE TO DRIP EMITTERS: 3/4-INCH SIZE UNLESS OTHERWISE INDICATED, ROUTING IS DIAGRAMMATIC UV RADIATION RESISTANT POLYETHYLENE SLEEVES: CLASS 200 PVC REMOTE CONTROL VALVE ASSEMBLY FOR SPRINKLER LATERALS: WEATHERMATIC MAX-DW (SIZED PER PLAN) F FLOW SENSOR ASSEMBLY: WEATHERMATIC SLFSI-T10 MASTER VALVE ASSEMBLY: WEATHERMATIC MAX-DW FLUSH CAP ASSEMBLY POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 30 PSI 8 FEET Q-0.26 H-0.52 F-1.05 POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES 30 PSI 10 FEET Q-0.41 H-0.82 F-1.64 POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): Q-0.65 H-1.30 F-2.60 30 PSI 12 FEET WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): Q-0.92 H-1.85 F-3.70 30 PSI 15 FEET WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD U-SERIES NOZZLES POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): EST-0.61 SST-1.21 30 PSI 4 FEET X 15 FEET WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD MPR SERIES NOZZLE POP-UP SPRAY SPRINKLER: PRESSURE: RADIUS: FLOW (GPM): 30 PSI VARIES WEATHERMATIC MAX6PRS30-CV W/RAIN BIRD HE-VAN SERIES NOZZLE HEVAN08-1.17 HEVAN10-1.78 HEVAN12-2.37 HEVAN15-3.70 CLASS 200 PVC PIPE SIZE FLOW (GPM) 1" 0-15 1-1/4" 16-25 1-1/2" 26-35 2" 36-55 2-1/2" 56-80 3" 81-110 4" 111-200 IF THERE IS A DISCREPANCY BETWEEN PIPE SIZES SHOWN ON THE DRAWINGS AND THIS PIPE SCHEDULE, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTACT THE IRRIGATION DESIGNER FOR CLARIFICATION. BACKFLOW PREVENTION ASSEMBLY: INSTALLED BY OTHERS BUBBLER ASSEMBLY FOR TREES IN GRATES: TWO (2) WEATHERMATIC MAX4PRS30-CV W/ RAINBIRD 1402 BUBBLER NOZZLE FLOW: 0.5 GPM PER BUBBLER (1.0 GPM PER TREE) PRESSURE: 30 PSI 1 2 3 4 PROJ. NO. DRAWN: CHECKED: DATE: © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: FINAL DEVELOPMENT PLAN APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 www.ozarch.com ARCHITECTURE ® PDP 1 04/17/2018 PDP 2 07/17/2018 PDP 3 08/15/2018 P+Z 09/04/2018 FDP 1 10/31/2018 FDP 2 12/12/2018 12/12/2018 As indicated WILLOW STREET RESIDENCES 118014.00 SH EP EP IR-001 IRRIGATION LEGEND AND NOTES NOTE: THE DISCREPANCY BETWEEN THE WATER BUDGET CALCULATION ON LANDSCAPE PLANS AND ANNUAL WATER USE CHART SHOWN ABOVE IS DUE TO 158 SQUARE FEET OF PLANTER BOXES THAT ARE TO BE HAND WATERED THUS ARE NOT CONSIDERED IN THE WATER BUDGET CALCULATION FOR THESE IRRIGATION PLANS.