HomeMy WebLinkAboutPROSPECT AND COLLEGE HOTEL - STAND ALONE MODIFICATION - MOD180001 - SUBMITTAL DOCUMENTS - ROUND 1 - (3)Page 1 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
STAND ALONE MODIFICATION REQUEST _PROSPECT + COLLEGE HOTEL
FT. COLLINS COLORADO
19 JULY 2018
PROJECT OVERVIEW
Page 2 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
N
SITE LOCATION
Page 3 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
EXISTING CONDITIONS [site]
looking north looking south
looking east looking west
Page 4 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
EXISTING CONDITIONS [context buldings]
looking north looking south
looking east looking west
CSU Heath Medical Center
“The Summit” Student Housing
+0’-0” (sidewalk ave.)
+7’-0” (floor 01)
+81’-0” (peak)
+61’-0” (peak) +51’-0” (peak)
Page 5 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
EXISTING CONDITIONS [roads & intersections]
w. prospect rd. looking north
intersection of college & prospect looking west
Page 6 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
SITE CONSTRAINTS & SETBACKS
80ft setback from ROW
130ft setback from centerline
Prospect Road
and
College Avenue
Setbacks
Legend
setback_name
130ft
80ft
GIS_RoadE911
QSection
Section
GIS_Lot
²
80ft setback from ROW
130ft setback from centerline
Prospect Road
and
College Avenue
Setbacks
By: Fort Collins, Colorado
Legend
setback_name
130ft
80ft
GIS_RoadE911
QSection
Section
GIS_Lot
²
0 50 100
Feet
80ft setback from ROW
130ft setback from centerline
Prospect Road
and
College Avenue
Setbacks
By: Fort Collins, Colorado
Legend
setback_name
130ft
80ft
GIS_RoadE911
QSection
Section
GIS_Lot
²
0 50 100
Feet
State Highway Development Standards:
Land Use Code section 4.9.1.
- US Highway 287 (S. College Ave.) - minimum setback is 130’ from
centerline of the right-of-way or 80 feet from the right-of-way line,
whichever is greater
- Prospect Road - (Arterial) 110’ building setback from center line of right-
of-way (Prospect Road street scape program)
Page 7 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
TOD Overlay District:
Off-street parking shall be located behind, above, within or below street-facing
buildings to the maximum extent feasible. No parking will be allowed between
the street and the front or side of a building
Flat-roofed buildings shall feature three-dimensional cornice treatment on all
walls facing streets or connecting walkways, or a rail at the top of the wall of a
usable rooftop deck, unless the top floor is stepped back to form a usable roof
terrace area.
-Buildings shall have a base portion consisting of one (1) or two (2)
stories.
-Buildings greater than two (2) stories in height shall also be designed so
that upper portions of the building are stepped back from the base
Parking
Within TOD, current feedback is there is a lack of parking: To address
these concerns, the City Council adopted a “stop-gap” ordinance
requiring minimum off-street parking in the TOD Overlay Zone. The
temporary minimum requirement is 70% of the existing standard with
an alternative compliance element that permits reduced parking if
supported through a parking impact study. (City of FOCO Transit-
Oriented Development Parking Study, 2014)
SITE LOCATION WITHIN
THE TOD OVERLAY ZONE
TRANSIT- ORIENTED DEVELOPMENT OVERLAY ZONE
SITE LOCATION & ZONING
Fort Collins Land Use Code:
4.21 - General Commercial District (C-G) and Multi-Use Zone -
Design Review Board Required
(D) Land Use Standards . The maximum building height shall
be four (4) stories.
3.2.2. – Lodging – parking minimum .5/unit, maximum 1/unit (since within
TOD, 25% of gross sf can be exempt from parking requirement, not to
exceed 5000sf)
Page 8 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
Hotel Public Space Prototypes
fitness_wellness meetings_terraces lobbies_lounges
standard guest room
Page 9 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
W. Prospect Rd. CONCEPTUAL SITE PLAN
N
0’ 20’ 40’ 80’
Program Summary
Level 02 - 28 Keys
Level 03 - 33 Keys
Level 04 - 33 Keys
Level 05 - 33 Keys
Level 06 - 22 Keys
Total 149 Keys
Building Height:
Level 01 - 18’-0”
Level 02 - 11’-0”
Level 03 - 11’-0”
Level 04 - 11’-0”
Level 05 - 11’-0”
Level 06 - 11’-0”
Total: 75 ‘-0” (top of parapet @ main roof)
80’-0” (top of high parapet @ entry)
Parking Required:
0.5/key (Code) = 75 spaces
1.0/key (typ. hotel standard) = 149 spaces
Parking Provided:
127 Surface Spaces
80’-0” ROW setback
6 parking spaces
encroach into setback
25’-0” +/- encroachment @ ground floor
32’-0” +/- encroachment @ upper floors
possible
vehicular
access
possible
left
turn in
right in /right out
bike pkg
possible
connection to
bike route
existing bike route
possible
vehicular
access
possible
vehicular
access
possible
emergency vehicle
egress
S. College Ave.
15 15 15
26
18
13
16
7
existing bike route
ride share / EV
Page 10 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
CONCEPTUAL FLOOR PLANS
N
0’ 05’ 10’ 20’
LEVEL 01
LOBBY/ FRONT DESK
LOUNGE/BAR/
LIBRARY
BREAKFAST
BOH/
LOADING/
SERVICE
W
M
KITCHEN
ADMIN/ BOH
GUEST
LAUNDRY
FLEX/ MEETING
PRE
FUNCTION
16
7
15 15 15
LEVEL 02
Page 11 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
N
LEVELS 03-05 LEVEL 06
0’ 05’ 10’ 20’
TERRACE EXERCISE
TERRACE EXERCISE
CONCEPTUAL FLOOR PLANS
Page 12 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
looking from northwest looking from northeast
CONCEPTUAL BUILDING FORM & MASSING
Note: Extend the natural character of the College Ave.
Parkway along the east side of site. “Open up” the site
along the south east corner to draw pedestrian energy
into property. Incorporate high quality hardscape &
plant materials into front plaza.
Page 13 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
looking from southeast looking from southwest
CONCEPTUAL BUILDING FORM & MASSING
note: building massing steps back along south &
west elevations. 6th floor rooftop amenity space
additionally steps back to reduce bulk.
Page 14 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
south elevation east elevation
CONCEPTUAL BUILDING ELEVATIONS
level 01
+0’-0”
level 02
+18’-0” (+/-)
level 03
+29’-0” (+/-)
level 04
+40’-0” (+/-)
level 05
+51’-0” (+/-)
level 06
+62’-0” (+/-)
low parapet
+75’-0” (+/-)
high parapet
+80’-0” (+/-)
NOTES:
Top floor @ +62’ above grade = below high rise
Materials & fenestration patterns change @ levels 05 & 06 to
create horizontal datum along College Ave. & articulate top
Building massing steps back and changes materials at Level 06
along south elevation. Roof canopy extends to articulate top
Entry massing and materials are highly transparent at south
east corner (building entry lobby, lounge and meeting spaces)
Window mullion cap extensions help to articulate Floors 02-04
and animate facades along primary frontages
Ground floor steps back 6-8’ along College Ave. to extend front
lawn and create building base articulation
1
2
3
4
5
6
1
2
3
4 4
5
5
6
Page 15 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
CONCEPTUAL BUILDING SECTION
level 01
+0’-0”
level 02
+18’-0” (+/-)
level 03
+29’-0” (+/-)
level 04
+40’-0” (+/-)
level 05
+51’-0” (+/-)
level 06
+62’-0” (+/-)
low parapet
+75’-0” (+/-)
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
GUEST ROOM
HOTEL FRONT-OF-HOUSE
LOBBY BEYOND
E-W section looking south through guest room wing
8’ +/-
offset
GUEST ROOM
possible solar PV over guestroom wing
Page 16 STAND ALONE MODIFICATION REQUEST - Prospect + College Hotel
CONCEPTUAL BUILDING SECTION
E-W section looking south through entry lobby
level 01
+0’-0”
level 02
+18’-0” (+/-)
level 03
+29’-0” (+/-)
level 04
+40’-0” (+/-)
level 05
+51’-0” (+/-)
level 06
+62’-0” (+/-)
high parapet
+80’-0” (+/-)
typical
guest
room
amenity
(bar/fitness)
roof terrace
east terrace
meeting
space
pre-function
space
check in
lobby
lounge bar west
terrace
exterior sun control device
over terraces, typical