Loading...
HomeMy WebLinkAboutFTC MUGS COFFEE SC, WTE (VERIZON) - PDP - PDP170031 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC MUGS COFFEE SC 714 S COLLEGE AVE FT. COLLINS, COLORADO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: MERGE ONTO I-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W, FOLLOW SIGNS FOR FORT COLLINS/BOULDER. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, CONTINUE SOUTH ON COLLEGE AVE PAST LAUREL STREET, THE SITE AND PARKING ENTRANCE WILL BE ON THE LEFT. FT. COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 VENTUREPRO LLLP, ROBIN & CHRISTIAN BACHELET CONTACT: ROBIN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: Ram.Nandiraju@verizonwireless.com RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. EM EM EM ET ET VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" REVISION SCHEDULE REV A DATE 06-19-17 BY VP VP VP VP VP VP VP VP 3'-0" 3'-0" EM EM EM ET ET 10'-0" 5'-0" GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 8. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 9. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 10. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 11. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 12. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 13. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 14. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 15. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 16. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS 39'-5" 44'-9" 47'-9" 39'-5" REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED ELEVATIONS Z-3 5 PROPOSED QUASI-OMNI ANTENNA WITHIN FAUX CHIMNEY NOTE: FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 2 Z-3 ELEVATION SCALE: 1/16" = 1'-0" PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S FACADE PROPOSED NON-PENETRATING PEAK MOUNT PROPOSED VERIZON RAD CENTER 44'-9" AGL TOP OF ROOF 39'-5" AGL TOP OF PROPOSED SHROUD 47'-9" AGL 1 Z-3 ELEVATION SCALE: 1/16" = 1'-0" 130'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-4 PROPOSED LINE OF SIGHT SCALE: N.T.S. REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED LINE OF SIGHT Z-4 6 S COLLEGE AVE EXISTING BUILDING'S CROSS SECTION EXISTING SIDEWALK EXISTING CURB PROPOSED LINE OF SIGHT FROM 5'8" IN THE MIDDLE OF THE SIDEWALK ACROSS S COLLEGE AVE EXISTING CURB PROPOSED QUASI-OMNI ANTENNA WITHIN CONCEALING SHROUD PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE PROPOSED NON-PENETRATING PEAK MOUNT TOP OF ROOF 39'-5" AGL PROPOSED COAX ROUTED IN CONDUIT WITH SHROUD TO MATCH EXISTING DOWNSPOUT 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. A SECTOR CABLE TABLE N/A AZIMUTH 80'-0" LENGTH 2 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 7/8" COAX REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED EQUIPMENT PLAN Z-2 4 N PROPOSED EQUIPMENT CABINET MOUNTED ON EXISTING WALL PROPOSED POWER PANEL MOUNTED ON EXISTING WALL PROPOSED 3'x3'x8'-4" FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (2) PROPOSED RRH'S AND DIPLEXERS MOUNTED ON EXISTING WALL PROPOSED QUASI-OMNI ANTENNA MOUNTED ON PROPOSED NON-PENETRATING PEAK MOUNT PROPOSED COAX RUN THROUGH DROP CEILING TO EXTERIOR PROPOSED COAX RUN THROUGH CONCEALED EXTERIOR CONDUIT PAINTED TO MATCH BUILDING'S EXTERIOR EXISTING POWER PANEL PROPOSED NON-PENETRATING PEAK ROOF MOUNT INSTALL CHECK METER TO PROPOSED ELECTRICAL RUN 1 Z-2 EQUIPMENT PLAN UPPER LEVEL DETAIL SCALE: 1/16"=1'-0" 2 Z-2 EQUIPMENT PLAN GROUND LEVEL DETAIL SCALE: 1/16"=1'-0" PROPOSED FIBER VAULT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED ELECTRICAL LINE TO EXISTING POWER PANEL 1 Z-4 2 Z-3 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 8 0 4 8 16 32 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED SITE PLAN Z-1 3 EXISTING CURB (TYP) EXISTING SIDEWALK LEGEND W SS F GAS GAS OE UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O O U/G OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET PROPOSED EQUIPMENT CABINET MOUNTED ON EXISTING WALL PROPOSED FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE (2) PROPOSED RRH'S MOUNTED ON EXISTING WALL PROPOSED QUASI-OMNI ANTENNA MOUNTED ON PROPOSED NON-PENETRATING PEAK MOUNT (SEE ELEVATION 2/Z-3) PROPOSED COAX RUN TO PROPOSED ROOF EQUIPMENT EXISTING POWER PANEL S COLLEGE AVE EXISTING FIBER LINE PROPOSED FIBER VAULT PROPOSED 5' WIDE ACCESS AND UTILITY EASEMENT PROPOSED 5'x10' VERIZON LEASE AREA (SEE DETAIL 2/Z-2) EXISTING 6' WIDE ELECTRICAL EASEMENT VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING 2 Z-3 1 Z-4 NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 15 0 7.5 15 30 60 1 inch = 30 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-3 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL: (2) RRHS, (1) POWER PANEL, AND (1) EQUIPMENT CABINET MOUNTED TO THE WALL IN THE LOWER PARKING STRUCTURE. 2. INSTALL NEW NON-PENETRATING PEAK ROOF MOUNT WITH A QUASI-OMNI ANTENNA WITHIN A FAUX CHIMNEY PAINTED & TEXTURED TO MATCH EXISTING BUILDING'S BRICK FACADE. 3. INSTALL UNDERGROUND FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE. 4. INSTALL NEW COAX CABLE FROM THE EQUIPMENT CABINET THROUGH THE DROP CEILING, UP AN EXTERIOR CONDUIT PAINTED TO MATCH THE BUILDING'S EXTERIOR TO THE PROPOSED ROOF EQUIPMENT. 5. RUN NEW ELECTRICAL FROM THE EXISTING POWER PANEL IN THE PARKING STRUCTURE TO THE PROPOSED POWER PANEL AND EQUIPMENT BOX. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: COMMUNITY COMMERCIAL DISTRICT APN: 9713219004 PARCEL SIZE: 14,000 S.F. ELEVATION: 4995' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 39'-5"± AGL ANTENNA RAD CENTER: 44'-9" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 06-19-17 BY EGW PRELIMINARY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 6 SITE NAME: FTC MUGS COFFEE SC SITE ADDRESS: 714 S COLLEGE AVE FT COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0099 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 07-10-17 KRC FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 C 09-22-17 GAC REVISED LEGAL DESCRIPTION THE SOUTH 1/2 OF LOT 3; AND ALL OF LOT 4; IN BLOCK 127, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Z-4 LINE OF SIGHT PH-1 PHOTOSIMULATION VIEW