Loading...
HomeMy WebLinkAboutFLATS AT RIGDEN FARM - PDP - PDP140006 - PLANS - ELEVATIONS46' Maximum 1 W-CRM W-SB R-CS W-SW 2 3 4 5 6 W-SV 9 11 46' Maximum 1 R-CS 2 4 5 6 7 8 W-SW W-SB W-CRM W-SV 9 MATERIALS LEGEND R-CS COMPOSITION SHINGLES - WARM GRAY COLOR W-CRM CORRUGATED RUSTED METAL SIDING W-CGM CORRUGATED METAL SIDING - PREFINISHED IN GRAY W-SB STUCCO - BUFF COLOR W-SG STUCCO - SAGE GREEN COLOR W-SW STUCCO - OFF WHITE COLOR W-SV SYTHETIC STONE VENEER - BUFF COLOR NOTE: 3 BUILDING COLOR SCHEMES PROVIDED WITH STUCCO & METAL SIDING COLOR VARYING AMONG THE SCHEMES. STONE VENEER & COMPOSITION SHINGLES TO REMAIN CONSTANT AMONG ALL BUILDINGS. CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 5:06:18 PM A-1 7/16/14 GDF The Flats at Rigden Farm Fort Collins, Colorado 20 Unit Bldg. Elevations 1 20 1/8" = Unit 1'-0" Building - Front Elevation 2 20 1/8" = Unit 1'-0" Building - Rear Elevation 46' Maximum 1 W-SB W-CRM 2 3 4 5 6 W-SV R-CS W-SW 7 5" 12" 3" 12" 3" 12" 3" 12" 5" 12" APPROX. 30' APPROX. 32' - 6" 1 W-SW W-CRM 2 3 4 5 6 R-CS W-SB 7 5 8 R-CS W-SV W-CRM 5 5" 12" 16' MAXIMUM APPROX. 9' - 6" W-SB W-SV W-SV W-CRM R-CS 5 MATERIALS LEGEND R-CS COMPOSITION SHINGLES - WARM GRAY COLOR W-CRM CORRUGATED RUSTED METAL SIDING W-CGM CORRUGATED METAL SIDING - PREFINISHED IN GRAY W-SB STUCCO - BUFF COLOR W-SG STUCCO - SAGE GREEN COLOR 1 2 3 4 5 6 9 35' MAXIMUM W-SB W-SW W-CGM R-CS W-SV 1 4 2 5 6 7 8 9 R-CS W-SV W-CGM W-SB W-SW 1 W-SW W-CGM 2 3 4 5 6 R-CS W-SW 7 W-SV 1 W-SB W-CGM 2 3 4 5 6 W-SV R-CS W-SW 7 5" 12" 3" 12" 3" 12" 5" 12" 3" 12" 35' MAXIMUM 1 W-SG 2 3 4 5 6 7 W-SV W-SW W-SG W-CRM 1 W-SG R-CS 2 3 4 5 6 W-SW W-CRM W-SV 9 1 W-SV R-CS 2 4 5 6 W-SG W-CRM 7 8 W-SW 1 W-SG 2 3 4 5 6 R-CS W-SW 7 W-CRM W-SV 45' Maximum APPROX. 30' APPROX. 31' - 6" 10 MATERIALS LEGEND R-CS COMPOSITION SHINGLES - WARM GRAY COLOR W-CRM CORRUGATED RUSTED METAL SIDING W-CGM CORRUGATED METAL SIDING - PREFINISHED IN GRAY W-SB STUCCO - BUFF COLOR W-SG STUCCO - SAGE GREEN COLOR W-SV W-CGM W-SW 12 13 14 35' MAXIMUM APPROX. 25' 4 R-CS MATERIALS LEGEND R-CS COMPOSITION SHINGLES - WARM GRAY COLOR W-CRM CORRUGATED RUSTED METAL SIDING W-CGM CORRUGATED METAL SIDING - PREFINISHED IN GRAY W-SB STUCCO - BUFF COLOR W-SG STUCCO - SAGE GREEN COLOR W-SW STUCCO - OFF WHITE COLOR W-SV SYTHETIC STONE VENEER - BUFF COLOR NOTE: 3 BUILDING COLOR SCHEMES PROVIDED WITH STUCCO & METAL SIDING COLOR VARYING AMONG THE SCHEMES. STONE VENEER & COMPOSITION SHINGLES TO REMAIN CONSTANT AMONG ALL BUILDINGS. CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 5:07:41 PM A-5 7/16/14 GDF The Flats at Rigden Farm Fort Collins, Colorado Commercial Bldg. Elevations 1 Commercial 1/8" = 1'-0" - West Elevation 2 Commercial 1/8" = 1'-0" - East Elevation 3 Commercial 1/8" = 1'-0" - South Elevation 4 Commercial 1/8" = 1'-0" - North Elevation KEYNOTES 1 STEEL RAILING PAINTED DEEP GRAY 2 TUBE STEEL COLUMNS PAINTED DEEP GRAY 3 SANDSTONE CAP 4 REVEAL IN STUCCO 5 CEMENT FIBER BOARD FASCIA PAINTED DEEP BROWN 6 MECHANICAL EQUIPMENT SCREEN WALL - ALL AC UNITS & METERS TO BE LOCATED WITHIN 7 TUBE STEEL BRACKETS PAINTED DEEP GRAY 8 ALUMINUM GARAGE DOORS PAINTED WARM GRAY 9 FIREPLACE VENT - FINAL LOCATION TO BE DETERMINED BY ARCHITECT OF RECORD Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 3 stories Bldg. 2 2 stories Bldg. 3 2 stories Bldg. 7 3 stories View D View C View A View B View E Illustrations shown herein have been created by taking digital photographs at the locations illustrated on the site reference plan and then overlaying them with a Revit model of the proposed buildings. Based on this analysis, the proposed project does not have an adverse affect on the adjacent properties. Buildings proposed on the west side of the property are all two story structures which do not exceed 40' in height. Buildings on the east exceed 40' in height only at the uppermost ridgelines. The proposed buildings are also comparable in scale and height to the adjacent buildings respective to each side of the project. Furthermore proposed building massing is varied in height, undulation, materials and colors providing visual interest. VISUAL ANALYSIS NOTES: CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 3:55:54 PM A-7 7/16/14 GDF The Flats at Rigden Farms Fort Collins, Colorado Visual Analysis View B - Looking West from Custer & Iowa - PROPOSED 1 Site 1" = 80'-0" Reference Plan NORTH View A - Looking Northwest from Custer & Iowa - PROPOSED View A - Looking Northwest from Custer & Iowa - EXISTING View B - Looking West from Custer & Iowa - EXISTING View C - Looking Southwest from Limon & Iowa - PROPOSED View C - Looking West from Limon & Iowa - PROPOSED View D - Looking Southwest from Limon & Iowa - EXISTING View D - Looking West from Limon & Iowa - EXISTING View E - Looking Northwest from Stoop of Adjacent Townhomes - PROPOSED 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Bldg. 1 2 stories Bldg. 4 3 stories Bldg. 5 3 stories Bldg. 6 Bldg.stories 2 3 2 stories Bldg. 3 2 stories Bldg. 7 3 stories Illustrations shown herein have been created using an aerial photograph obtained from Google Earth as a base site which was then overlaid with a site plan of the proposed project and further overlaid with a Revit model of the porposed buildings. Shadow analysis was then conducted using Revit software, using the site location and at the times of 9am, 12pm and 3 pm on the summer and winter solstices. Based on this analysis, the proposed project does not have an adverse affect on the adjacent properties. Minimal shadow impacts occur only for short periods in the late day for only a limited number of days surrounding the winter solstice. The property to the west is not impacted after 9am at any time of year. The properties to the north, northeast and east are only minorly impacted during the period mentioned above. And, the property to the south is not impacted at any time, as expected. SHADOW ANALYSIS NOTES: CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 3:55:14 PM A-6 7/16/14 GDF The Flats at Rigden Farms Fort Collins, Colorado Shadow Analysis 1" = 100'-0" Summer Solstice - 9am 1" = 100'-0" Summer Solstice - 12pm 1" = 100'-0" Summer Solstice - 3pm 1" = 100'-0" Winter Solstice - 9am 1" = 100'-0" Winter Solstice - 12pm 1" = 100'-0" Winter Solstice - 3pm 10 ELECTRICAL GEAR - PAINT ALL CABINETS TO MATCH BUILDING MATERIALS 11 AC UNITS - SEE LANDSCPE PLAN FOR SCREENING 12 INSULATED GLAZING IN ANODIZED ALUMINUM STOREFRONT 13 PRE-FINISHED METAL FASCIA - GRAY COLOR 14 STONE OR PRE-CAST CONCRETE SILL W-SW STUCCO - OFF WHITE COLOR W-SV SYTHETIC STONE VENEER - BUFF COLOR NOTE: 3 BUILDING COLOR SCHEMES PROVIDED WITH STUCCO & METAL SIDING COLOR VARYING AMONG THE SCHEMES. STONE VENEER & COMPOSITION SHINGLES TO REMAIN CONSTANT AMONG ALL BUILDINGS. CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 5:07:25 PM A-4 7/16/14 GDF The Flats at Rigden Farm Fort Collins, Colorado 10 Unit Bldg. Elevations 1 10 1/8" = Unit 1'-0" Building - Left Side Elevation 2 10 1/8" = Unit 1'-0" Building - Front Elevation 3 10 1/8" = Unit 1'-0" Building - Rear Elevation 4 10 1/8" = Unit 1'-0" Building - Right Side Elevation KEYNOTES 1 STEEL RAILING PAINTED DEEP GRAY 2 TUBE STEEL COLUMNS PAINTED DEEP GRAY 3 SANDSTONE CAP 4 REVEAL IN STUCCO 5 CEMENT FIBER BOARD FASCIA PAINTED DEEP BROWN 6 MECHANICAL EQUIPMENT SCREEN WALL - ALL AC UNITS & METERS TO BE LOCATED WITHIN 7 TUBE STEEL BRACKETS PAINTED DEEP GRAY 8 ALUMINUM GARAGE DOORS PAINTED WARM GRAY 9 FIREPLACE VENT - FINAL LOCATION TO BE DETERMINED BY ARCHITECT OF RECORD 10 ELECTRICAL GEAR - PAINT ALL CABINETS TO MATCH BUILDING MATERIALS 11 AC UNITS - SEE LANDSCPE PLAN FOR SCREENING 12 INSULATED GLAZING IN ANODIZED ALUMINUM STOREFRONT 13 PRE-FINISHED METAL FASCIA - GRAY COLOR 14 STONE OR PRE-CAST CONCRETE SILL APPROX. 22' APPROX. 19' - 8" MATERIALS LEGEND R-CS COMPOSITION SHINGLES - WARM GRAY COLOR W-CRM CORRUGATED RUSTED METAL SIDING W-CGM CORRUGATED METAL SIDING - PREFINISHED IN GRAY W-SB STUCCO - BUFF COLOR W-SG STUCCO - SAGE GREEN COLOR W-SW STUCCO - OFF WHITE COLOR W-SV SYTHETIC STONE VENEER - BUFF COLOR NOTE: 3 BUILDING COLOR SCHEMES PROVIDED WITH STUCCO & METAL SIDING COLOR VARYING AMONG THE SCHEMES. STONE VENEER & COMPOSITION SHINGLES TO REMAIN CONSTANT AMONG ALL BUILDINGS. CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 5:07:00 PM A-3 7/16/14 GDF The Flats at Rigden Farm Fort Collins, Colorado 12 Unit Bldg. Elevations 1 12 1/8" = Unit 1'-0" Building - Front Elevation 2 12 1/8" = Unit 1'-0" Building - Rear Elevation KEYNOTES 1 STEEL RAILING PAINTED DEEP GRAY 2 TUBE STEEL COLUMNS PAINTED DEEP GRAY 3 SANDSTONE CAP 4 REVEAL IN STUCCO 5 CEMENT FIBER BOARD FASCIA PAINTED DEEP BROWN 6 MECHANICAL EQUIPMENT SCREEN WALL - ALL AC UNITS & METERS TO BE LOCATED WITHIN 7 TUBE STEEL BRACKETS PAINTED DEEP GRAY 8 ALUMINUM GARAGE DOORS PAINTED WARM GRAY 9 FIREPLACE VENT - FINAL LOCATION TO BE DETERMINED BY ARCHITECT OF RECORD 10 ELECTRICAL GEAR - PAINT ALL CABINETS TO MATCH BUILDING MATERIALS 11 AC UNITS - SEE LANDSCPE PLAN FOR SCREENING 12 INSULATED GLAZING IN ANODIZED ALUMINUM STOREFRONT 13 PRE-FINISHED METAL FASCIA - GRAY COLOR 14 STONE OR PRE-CAST CONCRETE SILL 3 12 1/8" = Unit 1'-0" Building - Left Side Elevation 4 12 1/8" = Unit 1'-0" Building - Right Side Elevation W-SW STUCCO - OFF WHITE COLOR W-SV SYTHETIC STONE VENEER - BUFF COLOR NOTE: 3 BUILDING COLOR SCHEMES PROVIDED WITH STUCCO & METAL SIDING COLOR VARYING AMONG THE SCHEMES. STONE VENEER & COMPOSITION SHINGLES TO REMAIN CONSTANT AMONG ALL BUILDINGS. 14' - 0" 3' - 4" 3" 3" 3' - 1 1/2" 1" 3' - 1 1/2" 3" 3" 3' - 4" 6' - 0" STEEL TRASH ENCLOSURE GATES MOUNTED TO STEEL PIPE COLUMNS W-SV CURRENT ISSUE: DRAWN BY: BIDDING ISSUE: PERMIT ISSUE: CONST. ISSUE: REVISIONS: Architect 3115 Clyde St. | Fort Collins, CO 80524 | 90.484.8433 7/15/2014 5:06:37 PM A-2 7/16/14 GDF The Flats at Rigden Farm Fort Collins, Colorado 20 Unit Bldg. / Garage Elevations 1 20 1/8" = Unit 1'-0" Building - Right Side Elevation 2 20 1/8" = Unit 1'-0" Building - Left Side Elevation KEYNOTES 1 STEEL RAILING PAINTED DEEP GRAY 2 TUBE STEEL COLUMNS PAINTED DEEP GRAY 3 SANDSTONE CAP 4 REVEAL IN STUCCO 5 CEMENT FIBER BOARD FASCIA PAINTED DEEP BROWN 6 MECHANICAL EQUIPMENT SCREEN WALL - ALL AC UNITS & METERS TO BE LOCATED WITHIN 7 TUBE STEEL BRACKETS PAINTED DEEP GRAY 8 ALUMINUM GARAGE DOORS PAINTED WARM GRAY 9 FIREPLACE VENT - FINAL LOCATION TO BE DETERMINED BY ARCHITECT OF RECORD 10 ELECTRICAL GEAR - PAINT ALL CABINETS TO MATCH BUILDING MATERIALS 11 AC UNITS - SEE LANDSCPE PLAN FOR SCREENING 12 INSULATED GLAZING IN ANODIZED ALUMINUM STOREFRONT 13 PRE-FINISHED METAL FASCIA - GRAY COLOR 14 STONE OR PRE-CAST CONCRETE SILL 3 Garage 1/8" = 1'-0" - Front Elevation 4 Garage 1/8" = 1'-0" - End Elevation 5 Garage 1/8" = 1'-0" - Rear Elevation 6 Trash 1/4" = 1'-0" Enclosure Elevation KEYNOTES 1 STEEL RAILING PAINTED DEEP GRAY 2 TUBE STEEL COLUMNS PAINTED DEEP GRAY 3 SANDSTONE CAP 4 REVEAL IN STUCCO 5 CEMENT FIBER BOARD FASCIA PAINTED DEEP BROWN 6 MECHANICAL EQUIPMENT SCREEN WALL - ALL AC UNITS & METERS TO BE LOCATED WITHIN 7 TUBE STEEL BRACKETS PAINTED DEEP GRAY 8 ALUMINUM GARAGE DOORS PAINTED WARM GRAY 9 FIREPLACE VENT - FINAL LOCATION TO BE DETERMINED BY ARCHITECT OF RECORD 10 ELECTRICAL GEAR - PAINT ALL CABINETS TO MATCH BUILDING MATERIALS 11 AC UNITS - SEE LANDSCPE PLAN FOR SCREENING 12 INSULATED GLAZING IN ANODIZED ALUMINUM STOREFRONT 13 PRE-FINISHED METAL FASCIA - GRAY COLOR 14 STONE OR PRE-CAST CONCRETE SILL