Loading...
HomeMy WebLinkAboutWEST RANGE FORT COLLINS - PDP - PDP120028 - PLANS - LANDSCAPE PLAN (3)WEST LAUREL STREET SOUTH MELDRUM STREET WEST RANGE FORT COLLINS 2-STORY EXISTING STREET TREES TO REMAIN TREE INVENTORY & MITIGATION PLAN 4 SEE LANDSCAPE PLAN, SHEET 3, FOR MITIGATION TREE LOCATIONS TREE INVENTORY AND MITIGATION REQUIREMENTS # TYPE SIZE CONDITION REQUIRED MITIGATION TREES 1 APPLE 26" POOR 0 2 GREEN ASH 13" FAIR 1 3 HACKBERRY 17" FAIR 1.5 4 HACKBERRY 31" 2 5 SILVER MAPLE 17" FAIR-GOOD 2 6 BOXELDER 12" FAIR 1 7 AUSTRIAN PINE 30" FAIR-GOOD 4 8 GREEN ASH 11" POOR 0 9 GREEN ASH 7" POOR 0 10 HACKBERRY 16" FAIR-GOOD 2.5 11 HACKBERRY 13" FAIR 1.5 12 GREEN ASH 21" FAIR 3.5 13 HACKBERRY 17" FAIR-POOR 2 14 GREEN ASH 13" FAIR-POOR 1 15 GREEN ASH 17" FAIR-POOR 2 16 ELM 15" POOR 1 17 GREEN ASH 16" FAIR-GOOD 2 18 HACKBERRY 17" FAIR-GOOD 3 4 1. EXISTING TREES MARKED FOR PROTECTION AND PRESERVATION SHALL NOT BE REMOVED. 2. HEAVY EQUIPMENT SHOULD NOT BE ALLOWED TO COMPACT OVER THE ROOT ZONE OF EXISTING TREES. 3. AVOID CUTTING SURFACE ROOTS WHENEVER POSSIBLE. SIDEWALKS AND PAVING LEVELS SHOULD BE CONTOURED SUFFICIENTLY TO AVOID DAMAGE. 4. ROOT CUTS FROM EXCAVATION SHOULD BE DONE RAPIDLY. SMOOTH FLUSH CUTS SHOULD BE MADE. BACKFILL BEFORE THE ROOTS HAVE A CHANCE TO DRY OUT AND WATER THE TREE IMMEDIATELY. 5. PRIOR TO CONSTRUCTION, ALL PROTECTED TREES SHALL HAVE ORANGE PROTECTION BARRIER FENCING ERECTED, WHICH AS A MINIMUM ARE SUPPORTED BY 1" X 1" OR SIMILAR STURDY STOCK, FOR SHIELDING OF PROTECTED TREES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE HALF (1 2) OF THE DRIP LINE, WHICH EVER IS GREATER. WITHIN THIS PROTECTION ZONE THERE SHALL BE NO MOVEMENT OF EQUIPMENT OR STORAGE OF EQUIPMENT, MATERIALS, DEBRIS, FILL OR CUT UNLESS APPROVED BY THE CITY FORESTER. 6. ALL EXISTING TREES SHALL BE PRUNED TO THE CITY FORESTER'S "MEDIUM PRUNE STANDARDS. 7. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 8. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE OR DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE, WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 9. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 10. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BY "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN NOTE (5) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POSTS STAKES A MAXIMUM OF FIFTY FEET APART AND TYING A RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. TREE PROTECTION NOTES (R) TYPE COUNT REQUIRED MITIGATION TREES (P) = TREES BEING PRESERVED 3 0 (R) = TREES TO BE REMOVED 15 21 TOTAL 18 21 TREE MITIGATION SUMMARY (R) (R) (R) (R) (P) (R) (R) (R) (R) (P) (P) LOCATION COUNT MITIGATION TREES PROPOSED TO BE PLANTED ON-SITE 21 MITIGATION TREES PROPOSED TO BE PLANTED OFF-SITE 0 TOTAL 21 PROVIDED TREE MITIGATION (R) (R) (R) (R) 1. TREES TO BE PRESERVED ARE A CRITICAL SCREEN CLOSE TO THE BUILDING FOUNDATION. A QUALIFIED CERTIFIED PRIVATE ARBORIST WILL EVALUATE AND SUPERVISE EXCAVATION IN THE ROOT ZONE AND OTHER WORK IMPACTING THE TREES DURING CONSTRUCTION. DEPENDING ON THE AMOUNT OF ACTUAL ROOT CUTTING OR BRANCH PRUNING DETERMINED BY THE CERTIFIED ARBORIST TO HAVE OCCURRED RETENTION OF A TREE MAY NOT BE ADVISED. 1 2 3 5 6 7 17 16 18 8 9 10 11 12 15 (R) 13 14 (R) TREE PROTECTION NOTES DEVELOPER / APPLICANT WEST RANGE FORT COLLINS, LLC BRANDON GREBE 5232 SOUTHERN CROSS LANE FORT COLLINS, CO 80528 970.556.9111 SITE ENGINEER AND SURVEYOR NORTHERN ENGINEERING NICK HAWS, PE, LEED AP 200 S. COLLEGE AVE. SUITE 100 FORT COLLINS, CO 80524 970.221.4158 ARCHITECT VFLA JUSTIN LARSON 401 W. MOUNTAIN AVE., SUITE 100 FORT COLLINS, CO 970.224.1191 401 West Mountain Avenue Suite 100 Fort Collins, CO 80521 fax 970.224.1662 phone 970.224.5828 www.ripleydesigninc.com Ŷ land planning Ŷ landscape architecture Ŷ Ŷ urban design Ŷ entitlement Ŷ FORT COLLINS, COLORADO WEST RANGE FORT COLLINS IN ASSOCIATION WITH: PROJECT No.: R12-036 DRAWN BY: RDI REVIEWED BY: RDI SEAL: THIS IS A LAND USE PLANNING DOCUMENT, NOT A CONSTRUCTION DOCUMENT. REFER TO CIVIL ENGINEERING PLANS. PDP OF 8 ISSUED No. DESCRIPTION DATE 1 PDR 10.04.11 2 PDP 10.24.12 3 PDP RE-SUBMITTAL 12.12.12 REVISIONS No. DESCRIPTION DATE TRAFFIC DELICH ASSOCIATES MATT DELICH 2272 GLEN HAVEN DRIVE LOVELAND, CO 80538 970.669.5034 SCALE ACCORDINGLY IF REDUCED DRAWING NUMBER: LIGHTING ADONAI PROFESSIONAL SERVICES, INC. CHUCK POLSON 6931 BROADWAY DENVER, CO 80221 303.287.8091