Loading...
HomeMy WebLinkAboutFORT COLLINS JEEP - FDP170035 - CORRESPONDENCE - RESPONSE TO STAFF REVIEW COMMENTSP PARAGON ENGINEERING CONSULTANTS, INC. after- hours is vague. Response The note has been modified. Comment Number: 5 Comment Originated: 12/22/2017 12/22/2017: Please have the lighting designer call me to discuss the B-U-G ratings. Since the site does not adjoin a residential area, we are more concerned about the Glare ratings than the Backlight ratings. Response: The designer has spoken with the City and resolved the BUG rating issue. A note has been added to the plan calling for backlight shields on all fixtures along the ROW. Comment Number: 6 Comment Originated: 12/22/2017 12/22/2017: For the screen wall along Mason Street, the detail indicates the c.m.u. is to match, color, charcoal gray. Please provide a more specific reference as to what this color is matching and where it occurs on the building. Response: The note has been modified to specify matching the Best Block #858, Charcoal Gray that is to be used as the base element on the service portion of the building. See attached material board for color match. Comment Number: 7 Comment Originated: 12/22/2017 12/22/2017: Regarding the bollards, the note on the Site Plan needs to clearly state that these are to be painted Desert Tan. Or, instead of a note, you could a small detail to sheet L-2. Response: A note has been added to the Site Plan. Comment Number: 8 Comment Originated: 12/22/2017 12/22/2017: For the vinyl -clad chain link fencing, please specify the color of the vinyl. Staff recommends either black or dark green. Response: The vinyl -clad fencing will be color black. Comment Number: 9 Comment Originated: 12/22/2017 12/22/2017: Regarding the area west of the tracks, the site plan includes this area but the plat does not. This needs to be reconciled one way or the other. If this area is not included, and the Jeep dealership stores vehicles west of the tracks, then this would be a zoning violation. Response: The west parcel (Lot 2) is now a part of this project. No improvements are planned for this parcel. Comment Number: 10 Comment Originated: 12/22/2017 12/22/2017: A set of architectural elevations are needed prior to submittal of final mylars. The purpose of submitting a set for Final Plan review is to make sure that there are no undue delays at the time of recording the final mylars. Response: The architectural elevations are included with this submittal. Comment Number: 11 Comment Originated:. 12/22/2017 12/22/2017: For the mylars, please remove all ghosted layers. While these layers are helpful for plan review, they are not necessary for the final plans that are to be recorded. Also, the Existing Conditions Plan sheet, again helpful, but will not be needed for myiars. Response: All ghost layers have been removed from final plans. 7852 South Elati Street, Suite 106 %Littleton, CO 80120 / (303) 794-8604 / FAV (303) 795-307Z P PARAGON ENGINEERING CONSULTANTS, INC. January 31, 2018 Community Development and Neighborhood Services �6%6 281 North College Avenue Ai PO Box 580 (j' C Fort Collins, Co. 80522 w ID - Re: Fort Collins Jeep, FDP170035, Round 1 Comment Summary: Department: Planning Services Contact: Ted Shepard, 970-221-6343, tshepard@fcgov.com Topic: General Comment Number: 1 Comment Originated: 12/22/2017 On the Landscape Plan, there are 10 variegated maiden grass located between the screen wall along Mason Street and the parking lot. There appears to be sufficient area to continue this sequence of plants to the south to the landscape island at the corner instead of leaving this highly visible area without any plant material and simply treated with cobbles. Response: We have extended the plantings to the corner as suggested. Comment Number: 2 Comment Originated: 12/22/2017 12/22/2017: There are several landscape islands that also include light fixtures. Overtime as the trees mature, the illumination from these fixtures will diminish. Staff recommends that the light fixtures be placed independent of the landscape islands. Please note that if, over time, trees are removed for the benefit of the illumination, such removal would constitute a zoning violation. Response. The several of the light poles have been moved to create separation from trees in the islands. Comment Number: 3 Comment Originated: 12/22/2017 12/22/2017: Regarding the location of the electrical transformer, the applicant is reminded to submit the C- 1 Form to Light and Power. If a new transformer is needed, then please note on the Landscape Plan the new location closer to the east side of the building. Also, be sure to provide the proper clearances required by Light and Power. If moved, in the location of the existing transformer, please provide an increased number of shrubs to fill the island at maturity. Response: Noted Comment Number: 4 Comment Originated: 12/22/2017 12/22/2017: On the Lighting Plan, the note that indicates that fixtures will be dimmed after hours of operation needs to be more specific. This aspect of the site operations needs to be more specific. The note must also refer to the 10-volt wireless dimming system that will connect to modules on the fixtures that was described at P.D.P. Also, please indicate the extent to which the fixtures will be dimmed. For example, for recent project along an arterial street, the lighting design called for dimming to 50% of full illumination levels. And, the note should clearly specify the hours of the dimming as the reference to 7852 South Elati Street, Suite 106 1 Littleton, ('O 801201(303) 794-8604 / FAX (303) 795-3072