HomeMy WebLinkAboutPVH HEALTH SYSTEMS, HARMONY CAMPUS - MAJOR AMENDMENT - 32-98C - SUBMITTAL DOCUMENTS - ROUND 1 - TRAFFIC STUDYTable 2 Trip Generation (With Updated Floor Areas) Daily A.M. Peak P.M. Peak Land Use Trips Trips Trips Trips Trips in out in out INITIAL PHASE Medical Office - 122 KSF 4408 237 59 120 326 Hospital - 85.8 KSF 1440 61 22 19 60 Subtotal 5848 298 81 139 386 FUTURE PHASE Medical Office - 140 KSF 5058 272 68 139 379 Hospital - 260 KSF 4363 184 68 67 182 Health Club - 70 KSF 1200 51(1) 51 64(1) 64 - +20 KSF (3) Rehab/Alt. Medicine -.50 KSF 1807 97 25 49 134 Day Care - 10 KSF 793 67 60 62 70 Assisted Living - 180 Units. 387 7 4 17 14 Elderly Detached - 91 Units 210(2) 7 12 13 8 Suites Hotel - 75 Rooms 468 24 12 17 24 Subtotal 14,286 709 300 428 870 TOTAL 20,134 1007 381 567 1256 (1) Assumed directional split (2) Assumes PM = 10% of Daily (3) Another 20 KSF used only rehabilitation/alternative medicine APPENDIX A MEMORANDUM Co co LO o CD o TO: Angie Milewski, BHA Design • LO City of Fort Collins Staff O 0 6 CD a °C CD FROM: Matt Delich 0 O U DATE: September 7, 1999 • z X LL SUBJECT: PVH Harmony Campus - Radiation/Oncology Addition (File: 9817ME06) w O J This memorandum documents the trip generation for the CD N Radiation/Oncology Addition to the PVH Harmony Campus. This facility > Q a) is proposed to be located on the north side of the medical office 0 building that is currently approved. This facility will be used to w CDprovide radiation treatment of cancer patients and to evaluate new a patients. 2 w z There will be 16 full time employees with two of these being 0 o physicians. According to information supplied by the physicians, 35- 40 patients per day will be seen for treatment (4/hour) plus 6 new Cn patients for evaluation (spread over the entire day). This would N result in approximately 140 trip ends per day, using 2 trip ends per patient and 3 trip ends per employee. Using the medical/dental ITE office building use (Code 720) from Trip Generation, 6th Edition, results in the following, using number of employees as the trip generation variable: 143 daily trip ends 8 morning peak hour trip ends 17 afternoon peak hour trip ends It would appear that on a daily basis, use of the ITE reference reasonably reflects the expected trip generation for this facility. Appendix A shows the trip generation from the PVH Harmony a z Campus as documented in the traffic study and subsequent memoranda. ^ W The Radiation/Oncology Addition will increase the trip generation of z the initial phase of development by 2-3% on a daily and peak hour (.% basis. The Radiation/Oncology Addition will increase the trip J z W generation of full development by less than 1% on a daily and peak o hour basis. W 0 ~ It is concluded that the increase in trip generation due to the p Radiation/Oncology Addition will not significantly impact the 7 W operation of the key intersections. Additional evaluation was deemed a to not be necessary. ¢ W � LL QC ~ G