Loading...
HomeMy WebLinkAboutPROVINCETOWNE FIFTH - Filed GC-GENERAL CORRESPONDENCE - 2014-08-28city of Ft. Collins A rov Plans Approved By' Date A �=--- J R ENGINEERING March 29, 2013 Fort Collins Current Planning 281 N. College Ave. Fort Collins, CO 80524 RE: Provincetowne Filing 5 Statement of Planning Objectives To whom it may concern: Proposed Provincetowne Filing 5 is a replat of Lots 4-9 Block 7 and Lots 1-8 and 15-24 Block 8 Provincetowne Filing 3. The purpose of the resubdivision is to replat the existing residential lots into larger residential lots with an average area of 6,000 square feet. The results of the replat will be the elimination of 4 Provincetowne Filing 3 residential lots. The resulting replat will not change the character of the residential development and therefore has no impact to the existing development. All utility services have been adjusted to accommodate the new lot lines. The streets will be constructed per the approved Provincetowne Filing 3 Utility Plans except for the aforementioned utility services. Sincerely, Michael Brake, PE, PLS JR Engineering 2900 S. College Fort Collins, CO 80525 970.217-4911 mbrake@jrengineering.com 7200 South Alton Way, Suite C100, Centennial, CO 80112 303-740-9393 • FaN: 303-721-9019 • www.jrengineering.com Provincetowne Fifth Filing April 22, 2013 Plat Need to provide a note on the plat that identifies and indicates that the sidelot drainage easements dedicated on the Provincetowne Third Filing plat that are within the limits of this replat are vacated and rededicated as shown with this replat. All the other easements appear to match. Utility plans Have some layer/ line weight issues on some of the sheets. Example: on the utility plans the water services are shown light and dashed and I know that they are not existing. See plans for additional comments. Missing some text and information on some sheets — could be a layer issue. Sheri Langenberger From: Brake, Michael <MBrake@JREngineering.com> Sent: Tuesday, May 14, 2013 8:35 AM To: Courtney Levingston Cc: Roger Buffington; Sheri Langenberger Subject: FW: Provincetowne Filing 5 - Utility Plans All, Fort Collins -Loveland Water District and South Fort Collins Sanitation District approval for your records. Is there anything else I need from Terry? Regards, Michael Brake, PE, PLS Project Manager 2900 S. College Avenue, Suite 3D Fort Collins, CO 80525 970-217-4911 Cell From: tfarrill(abaol.com [mailto:tfarrill@aol.com] Sent: Tuesday, May 14, 2013 7:56 AM To: Brake, Michael Subject: Re: Provincetowne Filing 5 - Utility Plans Hi Mike, The Fort Collins - Loveland Water District and the South Fort Collins Sanitation District have approved the adjustments as submitted and have no further comments. Please do not hesitate to contact me if you have any questions or require additional information. Terry Mr. Terry W. Farrill, P.E. District Engineer Fort Collins - Loveland Water District South Fort Collins Sanitation District 5150 Snead Drive Fort Collins, CO 80525 Phone: (970) 226-3104 ext. 104 Fax: (970) 226-0186 tfarrill(aaaol.com -----Original Message ----- From: Brake, Michael <MBrake(cDJREngineering.com> To: TFarrill <TFarrill(@_AOL.com> Sent: Tue, May 14, 2013 7:39 am Subject: Provincetowne Filing 5 - Utility Plans Terry, Thanks for meeting with me yesterday to discuss the revised Provincetowne Plans for Filing 5. As we discussed we have eliminated several of the original platted lots and made adjustments to the water and sanitary sewer services to work with the adjusted lot lines. Please let us know if we have your approval. Regards, JR Engineering Michael Brake, PE, PLS Project Manager 2900 South College Ave Suite 3D Fort Collins, CO 80525 970.217.4911 cell mbrakea,*rengineering.com