Loading...
HomeMy WebLinkAboutPROSPECT II - Filed GC-GENERAL CORRESPONDENCE - 2011-12-09CITY 0I FUI?I CQUINS P.O. Box 580, Fort Collins, Colorado 80522 Ph(303)484-4220 Ext. 728 STORM WATER UTILITY Mr. Mike Schmid Engineering Professionals Excutive Plaza, Suite 110 2625 Redwing Road Fort Collins, CO 80526 Re: Prospect II P.U.D. Dear Mike, November 23, 1983 As I indicated to you over the phone this morning a problem has surfaced with the proposed design of the major storm conveyance system for the aboved referenced project. Bill Blackwell explained the proposed design to Bob Smith and myself yesterday. As I understand it the concept of the design is to route the major storm runoff from the Larimer No. 2 Canal overland through the private drive - parking area, instead of in a drainage channel as was originally proposed, to the drainageway located approximately in the middle of the project. After talking with the Assistant City Attorney about this proposed design he has indicated that the City should not approve this concept due to the potential hazard of high velocity water endangering life and property within the parking area. Bob Smith has agreed with this recommendation and will require an alternative design that will reduce the potential hazard. There is another problem regarding the proposed design for the major storm conveyance system and possible credit for basin fees. As you are aware since there are major storm drainage improvements that are required as stipulated in a Master Plan (Canal Importation improvements), these improvements can qualify for a credit in the basin fees. However since your proposed design is a significant change in the recommendations in the Master Plan the Storm Drainage Division cannot justify approving any credit. Please call me if you would like to meet and discuss these matters in more detail. Sincerely, '-P - 6. U Philip G. Waite Civil Engineer Ii, Storm Drainage Division cc: Bob Smith, Storm Drainage Marc Engemoen, Storm Drainage Mauri Rupel, Planning Department August 15, 1984 Mr. Marc Engemeon City of Fort Collins Storm Drainage Division P.O. Box 580 Fort Collins, CO 80522 Re: Prospect II, P.U.D., Box Culvert Dear Marc: engineering pmfe,%ionalS inc. Project No.: 298.2 Per our meeting on August 7, 1984, I am enclosing copies of calculations performed to determine the water surface elevation and the flows which could be accomodated for the double box culvert at the southeast corner of Prospect II P.U.D. As you are aware, we designed the box culvert and roadway crossing to pass the 100 year storm flows of 870 cfs as indicated in the "Storm Water Importation Canal Study" prepared by Resource Consultants, inc. The original design called for a total clear opening of 4' x 18' for the box culverts, but was inadvertantly constructed as 4' x 16' (double 4' x 81). The calculations performed were to check the effect of the water surface elevation due to the restricted size of the box culvert. The original design called for a water surface elevatin of 20.5 at the crossing. At this elevation, the amount of water being passed is 810 cfs. Calculations were then performed to check to surface elevation to pass 870 cfs. As indicated in the enclosed sheets, a water surface elevation of 20.7 will allow 904 cfs to pass. Please feel free to call concerning this matter if you have questions. KLR:psm ENC. Sincerely, ENGINEERING PROFESSIONALS, INC. ;r enneort th L.'Rabbers 2625 Redwing Rd. Suite 110 Fort Collins, Colorado 80526 • 303/226-3852 377 E. Agate, Suite 202 P.O. Box 500 Granby, Colorado 80446 9 303/887-2631 M en CITY OF FORT COLLINS MEMORANDUM DATE: June 5, 1985 TO: John McLean, Water & Sewer FROM: Craig Farver, Construction Inspector RE: Prospect Road Improvements at Prospect II It has come to my attention that there are signs of settlement on the curb, gutter and street adjacent to an existing manhole approximately 40-feet west of a storm sewer inlet on the south side of Prospect. According to the agreement Sterling Paving had with the developer, it was up to the City's Sewer Department to replace, raise, backfill and compact these manholes prior to road work proceeding. It is my feeling that due to improper compaction, the settling has occurred and I also feel that these repairs should be made as soon as possible inorder to eliminate any further deterioration of the asphalt and curb and gutter. Before repairs are made, please contact me at 221-6605 so we can go over the areas and the guantities of asphalt and curb and gutter that will need to be removed. Thanks! t+111111101' *90 GP"in¢ering prc�¢,�ionals inc. A CIVIL ENGINEERING AND LAND SURVEYING FIRM June 12, 1985 Mr. Dave Gray Steele Eagle, Inc. 3600 S. Yosemite, Suite 800 Denver, Colorado 80237 Re: Prospect II P.U.D. Dear Dave: Per your request, I have inquired as to whether the 4' x 2' box culvert for the Larimer #2 Outlet Channel, as shown on sheet 5 of 8 of the Prospect II Utility Plans, needs to be constructed with Phase II of the project. I discussed this with Tom Gathman of the City of Fort Collins Storm Drainage Utility and he confirmed that it does not need to be constructed at this time. However, please be aware that it may need to be constructed at a later date and the location as shown on the plans needs to be kept free of any structures or obstructions that could be damaged in the future. If we can be of further assistance, please feel free to call. Sincerely, ENGINEERING PROFESSIONALS, INC. Kenneth L. Rabbers KLR:psm cc: Tom Gathman Commumty Planning and EnvironmentaM ervices Engineering Department City of Fort Collins February 2, 1994 Richard Stork Stork Development P.O. Box 270218 Fort Collins, CO 80527 RE: Prospect II PUD Dear Richard: I have reviewed the City records on Prospect II PUD and find no record of a repayment agreement for the improvements to Prospect Road. The City has recently completed widening Prospect Road west of this site, but this parcel was not assessed any of the construction costs. If I can be of further assistance, please do not hesitate to call me at 221-6605 Sincerely, Matt J. Baker SID Coordinator 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6605