Loading...
HomeMy WebLinkAboutEVERGREEN PARK REPLAT BLOCK 4 LOTS 7 AND 8 - Filed CS-COMMENT SHEETS - 2008-10-23Selected Issues Report Citq a# Prtrt Colliun Date: 9/29/2008 IMPORT AUTO SALES, TOWING & STORAGE PDP - TYPE I SELECTION CRITERIA: Status = All ISSUES: Department: Engineering Issue Contact: Randy Maizland Topic: Engineering Number:2 Created:10/30/2007 Pending [10/30/07] Deeds of dedication: ROW and easement deeds of dedication were submitted without review fee payment. I have done a preliminary check of the easement documents however, the legal descriptions will not be reviewed by our survey division until all fees have been paid. The following dedications are needed for this project: 3 foot ROW dedication (submitted), 9 foot Utility Easement behind the ROW (nothing submitted), on -site Drainage Easement for the detention pond (nothing submitted), and an off -site Drainage & Utility Easement (submitted). To cut down on fees, you may combine the on -site & off -site easement into one document if you wish since they are connected and can be described in one legal description. Please submit 3 or 4 revised easement documents for review with the appropriate review fees and County recording fees. Please see the red -line Check Prints and Utility Plan comments attached for clarification. Number:3 Created:10/30/2007 Pending [10/30/07] Site Plan - Please show all existing and proposed easements (on & off -site) on the Site Plan drawing. Number:4 Created:10/30/2007 Pending [10/30/07] Please show and label all existing and proposed easements by separate document on the Utility Plan set, see redlines for clarification. Number:5 Created:10/30/2007 Pending [10/30/07] Call out the new driveway and H.C. ramps with the LCUASS standard. Please add the H.C. ramp standard to the Details on sheet 4. Number:6 Created:10/30/2007 Pending [10/30/07] Please show any existing driveway curb cuts on the west side of Red Cedar to verify that minimum standard driveway spacing will work. Submit a variance request for any spacing less than 50 feet CL to CL. List on Note 48 of the General Notes if a variance is requested. Number:7 Created:10/30/2007 Pending [10/30/07] Please show and label a type II barricade at the new sidewalk terminus on the south end. Number: 8 Created:10/30/2007 Pending Page 1 [10/301071 The drainage outfall to Conifer street should be through a standard LCUASS or Stormwater approved curb chase drain. Since there is existing C&G on Conifer, a standard chase drain can be constructed in the ultimate location for future sidewalk. Please show and call out on the plans with adequate spot elevations. Add the appropriate detail on sheet 4. Number:9 Created:10/30/2007 Pending [10/30/07] See redlines for any other minor comments related to drafting or labeling as well as easement dedication options. We will need either a signed deed of dedication or letter of intent from the owner of Lot 9 prior to scheduling a hearing. All other plan related issues can be resolved with Final Compliance. Department: Traffic Operations Topic: Traffic Number: 16 [11/12/071 No Issues. No Automotive TIS required. Issue Contact: Ward Stanford Created:11/12/2007 Pending Page 2