Loading...
HomeMy WebLinkAboutCAMBRIDGE PLACE PUD - Filed CS-COMMENT SHEETS - 2008-04-17DEPARTMENTDATE Zor)FST/c S���u St ZE � S,)4ceu F.QF X4�a. A-s Ae �— "o e::7-- nv /:> Of �7vST/AIG �v C/,v�S — �JOT,d� fi/iJftn!/ �1115. 1.'fleVc�yQld4�. New Me,LF �t��))', t 1� /(%• Grit,( , ETE A17iC1A) /NA7 Equt17E ��Joc<l C'xTEti7 cF i ivAi� r4-N �, arc H tUR ZEe 1 E(��g7i0 nl 4 O GATiDnf `rCTAA i5 ✓aJ Cr�RE.EL�' on/ S, I OW WILL �RuNJOFF 01=F-S'rE? �rzs,22 v RECEIVED JUN !oS? TO: Doug Martine, Light and Power PLANNtN3 FM: Bonnie Tripoli, Development Engineering Analyst DEPARTMENT RE: Subdivision Utility Plans DATE: 6-7-83 / /nSubmitted for your review and comment are utility plans for CIAm8R1DGL Rr4c.a P24-b. Please respond by -(O -7-4-83 J 484-4220 DEVELOPMENT CENTER EXT.655 June 28, 1983 Eldon Ward ZVFK Architects 218 West Mountain Fort Collins, CO 80521 Dear Eldon: Staff has reviewed the final site plan of Cambridge Place PUD and has the fol- lowing comments to make: 1. A 10 foot utility easement is needed along the north, west, and east property lines and a 6 foot easement is needed along the south property line. 2. The existing 3/4-inch water service may not be adequate to serve the proposed uses and may have to be replaced. 3. The size of all existing water lines needs to be shown. 4. The proposed fire hydrant should be identified as being "new" and located to the north side of the drive, if possible. 5. On -site detention may be inadequate. The extent of ponding and the highwater elevation need to be shown. How will runoff be released off site? 6. The new sidewalk along Shields Street should be 7 feet wide. 7. All dimensions of the building envelope need to be shown. The site's location is incorrectly shown on the vicinity map. 8. The loading zone is located within an acre that would obstruct emer- gency services access. Loading zones need to be a minimum of 500 square feet in size with no one dimension less than 10 feet. 9. Parkingostallolengths need to be a8 follgws: 30 - 45 - 20 feet long, 46 - 60 - 19 feet long If 2 foot overhangs are being used, wheel stops must be shown. W 10. Staff's evaluation of the point chart has the proposed project at 52%. There does not appear to be a joint parking situation. Three copies of the revised site plan reflecting these comments must be submit- ted to this office by Friday, July 8, 1983. By Monday, July 18, colored site plans, elevations, and an 812" x 11" reduction must be submitted. If you have any questions or comments, please don't hesitate to contact me. Sincerely, Sherry Albertson -Clark Project Planner SAC/gla