HomeMy WebLinkAboutPLEASANT VALLEY AND LAKE CANAL BRIDGE AT SOUTH OVERLAND TRAIL BELLA VIRA - Filed BC-BRIDGES & CULVERTS - 2008-02-06lqll�c At N a Y / PROJECT DESCRIPTION Project is a 14'-0" x 4'-0" cost -in -place box extension to on existing box crossing Overland Trail Road at the Pleasant Valley Lake Canal. The project name is "Bella Viral". GENERAL APPLICATION 1. These drawings must be used in conjunction with the civil drawings on the project to clearly define all requirements for construction. 2. No Contractor should attempt to bid or construct any portion of this project without consulting the project civil, municipality, mechanical, and electrical specifications, and/or General Notes. 3. These General Notes are intended to function as the structural portion of project specifications. 4. All things which, in the opinion of the Contractor, appear to be deficiencies, omissions, contradictions or ambiguities in the drawings shall be brought to the attention of the Structural Engineer. Corrections or written interpretations shall be issued before affected work may proceed. 5. The Contractor shall inform the Structural Engineer, clearly and explicitly in writing of any deviation or substitution from requirements of the contract documents. Contractor shall not be relieved of any requirement of the contract documents by virtue of the Structural Engineer's review of shop drawings, project data, etc., unless the Contractor has clearly and explicitly informed the Structural Engineer in writing of any deviations or substitutions at time of submission. DESIGN CRITERIA 1. Design Codes and Criteria for Construction: o. AASHTO b. Colorado Deportment Of Transportation, c. City of Fort Collins 2. Superimposed Gravity Loading: PER SHEET S2.00 J. All references ore latest edition unless noted otherwise. EXISTING CONSTRUCTION 1 Information on existing construction taken from drawings provided by Jonathan Sweet, P.E. Jim Sell Design, Inc. 153 West Mountain Ave. Fort Collins, CO 80524 Phone: (970) 484-1921 Fax: (970) 484-2443 All information, dimensions, elevations, etc. shall be considered approximate and shall 2, be field verified by contractor prior to ordering and/or fabricating material. 3. Report all discrepancies to the Construction Manager and Engineers. In as much as the addition, remodeling, retrofit, renovation or rehabilitation of on 4. existing building requires that certain assumptions ore made regarding existing conditions. The contractor must immediately notify the structural engineer If any existing condition deviates from those indicated in the contract documents. Contractor shall verify all existing conditions prior to ordering materials or proceeding 5. with new work in areas affected by existing conditions. Structural Engineer shall be informed in writing of conflicts between existing and proposed new construction. No openings nor any changes or additions shall be made in any existing structural elements 6. without written approval of the Structural Engineer. Where the function of on existing element as structural or non-structural is unclear, the determination of its function will be mode solely by the structural engineer. GEOTECHNICAL NOTES 1. Presumed bearing value of soil is to be confirmed at time of construction. See Foundation Note 1. 2. Bearing values are based upon telephone conversation with Lester Litton, P.E. Earth Engineering Consultants, on March 1, 2007 and letter dated May 24, 2007 project 1062104. See foundation Note 2. J. Provide free -draining sub grade preparation per 2/S1.00 per geotechnical recommendations. FOUNDATIONS 1. SOILS ENGINEER: I. Provide on open excavation inspection by a geotechnical engineer licensed in Colorado. Geotechnical engineer shall prepare a letter report confirming presumed soils criteria prior to construction of foundations. Do not construct work until confirmation of presumed criteria has been received by Structural Engineer. A copy of the letter of confirmation shall be submitted to the City. 2. Foundation and retaining walls have been designed for the following assumed design pressures: i. Presumed Bearing Pressure 2000 psf, 0 minimum I1. Active Pressure 45 psf/ft iil. At Rest Pressure 60 psf/ft iv. Passive Pressure 250 psf/ft V. Friction Coefficient 0.35 J. See sheet S2.00 for box culvert sections and notes. 4. All fill material shall be compacted in accordance with recommendations of COOT. Measurement and payment provisions do not apply. Contractor shall include cost of COOT specified backfill materials in the cost of the work. 5. Provide shoring and protection from the elements for excavation bottoms and sides as required to promote safety, prevent caving and washing, and to prevent undercutting of footings after they have been placed. 6. Brace all foundation walls against which backfill is to be placed until floor slabs at the top and bottom of the wall are in place. 7. Contractor shall provide continuous site drainage by a mechanical method to control surface and underground water as required to maintain a dry working site. MISCELLANEOUS NOTES 1. The Contractor is solely responsible for all safety regulations, programs and precautions related to oil work on this project. 2. The Contractor is solely responsible for the protection of persons and property either on or adjacent to the project and shall protect it against injury, damage, or loss. 3. Means and methods of construction and erection of structural materials are solely the Contractor's responsibility. 4. The structure is designed to function as a unit upon completion of construction of the project and then, only to support the design loads indicated. The contractor is responsible for means, methods and sequence of construction and the adequacy of the structure to support lads occurring during construction of the project. Furnish all temporary bracing, shoring, ono/or support as may be required. 5. No openings or any change in size, dimension or location shall be made in any structural element written approval of the Structural Engineer, 6. Show all openings through structural members on shop drawings and submit for review. Openings not shown on structural drawings ore subject to acceptance and shall be specifically indicated for review and acceptance. 7. No structural modifications, alterations, or repairs shall be made without prior review by Structural Engineer. Submit details. SUBMITTALS 1. Manufacturers Data: Submit two (2) copies of manufacturer's specifications and installation instructions for each product specified. Indicate by transmittal form that a copy of each instruction has been distributed to the appropriate contractor. 2. Shop Drawings: Submit one (1) reproducible and five (5) prints of each shop drawing. Reproducible copies of contract documents shall not be used as shop drawings. Shop drawings shall be reviewed by Contractor prior to submission. Drawings shall bear Contractors approval stamp accepting responsibility for coordination of dimensions shown in the contract documents, quantities and coordination with other trades. Drawings not bearing Contractors stomp may be rejected at the discretion of the Architect or Structural Engineer. Reproducible prints will be returned with the Architect/ Engineer comments. Allow 14 calendar days In the Structural Engineers office for review of shop drawings. J. Requests for Information (RFI) may use the Contractor's standard forms. Contractor shall send doted RFI information requests in writing when schedule and cost impacts ore anticipated. Contractor may request information verbally if no cost or schedule impact is anticipated. 4, Submittals: a. Concrete Mix Design b. Reinforcing bar shop drawings c. Handrail shop drawings QUALITY CONTROL 1. The Contractor is responsible for quality control, including workmanship and materials furnished by his subcontractors and suppliers. 2. Inspection or testing by the Owner does not relieve the Contractor of his responsibility to perform the Work in accordance with the Contract Documents. 3. Workmanship: The Contractor is responsible and shall bear the cost of correcting work which does not conform to the specified requirements. 4. Correct deficient work by means acceptable to the Engineer. The cost of extra work incurred by the Engineer to approve corrective work shall be borne by the Contractor. QUALITY ASSURANCE 1. Owner will engage a qualified Testing Agency, approved by the Engineer to perform tests and inspections required by these General Notes. 2. Testing Agency shall comply with ASTM E329 and shall furnish a certificate of compliance, signed by the Professional Engineer responsible for management of the Agency. 3. The Professional Engineer must be registered in the state where the project is located. 4. See General Notes above for required testing and inspection. SPECIAL INSPECTION 1. Special inspection is required for the following: a. Inspection of subgrode preparation operations by Geotechnical Engineer b, Placement of concrete reinforcement prior to closing of formwork and placing of concrete. c. Concrete placement and strength testing. d. Inspect all anchor bolts and embedments cast into concrete. 2. All welding with the exception of shop welding done in on approved fabricator's shop. The Contractor shall be responsible for notifying Special Inspector 72 hours in advance of required inspections for scheduling purposes. Failure to meet observation schedules may require removal (for inspection purposes) any finishes that have be subsequently installed. Approval by the special Inspector does not preclude observation by the Engineer of Record and approval by the FOR does not preclude the inspection process by the Special Inspector and nay, other code requirements for inspection. Removal and replacement of any finishes and/or framing damaged by the finish removal process or as required for corrective action sholl be at the Contractor's expense, not the Owner, Engineer nor Structural Observer. J. A pre -construction meeting including the Engineer of Record, the Contractor, Special Inspector, and appropriate Subcontractors shall be held to review the details of the structural systems to be inspected. 4. TWH may also provide verbal instructions to field supervision personnel as needed to ensure that the observed work conforms to contract documents, and will follow up site observations with a written report of items observed with noted deficiencies. V i t A A I I � \ \ \ \ \ OVER EXC,4VA77ON T/ WALL \ 5121.84' \ \ EXISTING CONCRETE ENCASED \ / v A �fF v DUCT BANK, FIELD VERIFY T �/ I ce cS _ � Q �l I zQn �T/WALL \ C) cc vv=512259' � \ \ ALIGN INSIDE WALLS OF NEW BOX WITH WALLS \ v v v v OF EXISTING BOX, TYP. S00 \ \ o \ \ S3�0 C& 2 r \ \ 53.00 \ \v _ INVERT ELEV. v _ = 5111.34' 3 vv v �I S 1.00 T/ WALL I STRUCTURAL INFO.) Q = 5122.59' - Z 3 3 RE: S3.00 AND S4.00 FOR RETAINING WALL DESIGN, TYP. SCALE : 1/8" = 1'-0" �T/ WALL 5121.84' 1_4 I i LAYOUT PLAN I ix J , EXISTING HEADWALL, DEMO PARAPET PER 1/S2.00 I 1 NOTE: CONFIRM ALL ELEVATIONS FLOW LINE, SHOWN WITH CIVIL + */_ Re CIVIL I ENGINEER RE: CIVIL �� l � \ I A I A \ I \ V A \ I OTPVLCPfAN.dwg PAVEMENT, RE: CIVIL 2 MAX o 14'-0" PERPENDICULAR SKEW LENGTH) Tw INVERT ELEV. SEE 3/S1.00 a .• PROVIDE 3'-O" CLASS 7 "REJECT" SUBGRADE BASE PREPARATION BOX CROSS SECTION_ SCALE 1" = 4'-0 3 S3.00 T/ WALL \ = 5122.59' I I I I A RE: S4.00 FOR WINGWALL-3 "BEYOND RE: 53.00 FOR SPECIFIC WALL DETAILS o INVERT ELEV. - 51- 11 34' I I�I 10'-0" SIDEWALK WEST 1}" COMPRESSIBLE POLYETHYLENE WRAP OVER TOP OF DUCT SEE 5/53.00 EXISTING CONCRETE ENCASED O DUCT BANK, FIELD VERIFY ELEVATION T/ DUCT a = 51- 1021' PER MINATTA SURVEY 3 2'-0' 20060630 SECTIONS.dwg CIVIL GENERAL LAYOUT SHOWN F EE SHEET S2.00 FOR BOX MENSIONS AND REINFORCING COMPACTED ON SITE MATERIAL COOT STRUCTURAL BACK FILL CLASS 1 RE: S2.00 FOR REINFORCING SCHEDULE AND DIMENSIONS 470 DRAIN TIED TO RETAINING WALL DRAIN BEYOND FLOW LINE, 5119.44 +/- SIDEWALK AT MID -WALL, RE: CIVIL SLIT 27 I --�-r� SLOPES, RE: CIVIL RE: PLAN GENERAL LAYOUT SHOWN SEE SHEET S3.00 FOR SPECIFIC DETAIL AT PARAPET HEADWALLS AND WINGWALLS BEYOND REMOVE EXISTING HEADWALL AND REINFORCE ADJACENT SLAB, RE I/S2.00 T/ WALL Q t - = 5177.57' B/ SLAB = EXISTING CULVERT, o FIELD VERIFY 'v SLOPES, RE: CIVILINVERT ELEV. ' CULVERT, j7;Av�V FIELD VERIFY EAST HATCH INDICATES EXISTING CULVERT TO REMAIN PROVIDE SUBGRADE BASE PREPARATION, RE: 2/S1.00 UTILITY NOTES FUTURE 4"0 (8) OZ EXISTING DUCT VERIFY W/ UTILITIES CONDUIT LOCATIONS SCHEMATIC LONGITUDINAL SECTION tLOOKING NORTH) SCALE : 1" = 4'-0 Structural Drawing List *** INCLUDED WHEN SHOWN NUMBERED *** S1.00 BOX CULVERT PLAN AND SECTIONS S2.00 TYPICAL BOX CULVERT REINFORCING 53.00 WING WALLS FOR BOX CULVERT S4.00 HEAD WALL ELEVATIONS AND RAIL DETAILS 20060630 SECTIONS.dwq FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT Mr. Micha . Di'Lullio, Maria =er Date Mr. T arrill, P.F., District Engineer Date All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. PLEASANT VALLEY AND LAKE CANAL COMPANY Approval Block REVIEW D BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY ON THIS DAY OF, 2090.7iHIS PLAT HAS BEEN SIGNED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY, BUT THIS SHALL NOT MEAN IT APPROVES THE ENGINEERING, SURVEYING, DESIGN, CONSTRUCTION, OR OTHER PROFESSIONAL WORK, THE SIGNATURES MEAN ONLY THAT THE COMPANY HAS SEEN THE SHEETS.. SIGNED, AND COOPERATED WITH THE OWNER IN PROVIDING INFORMATION. THE OWNER AND THE PROFESSIONALS IT HAS EMPLOYED ARE SOLELY RESPONSIBLE FOR THE END RESULT.` ROBERT UNDERHILL, PRESIDENT City of Fort Collins, Colorado UTILITY AN Approval APPROVED'. I q City Engineer Date CHECKED BY: N1 Ar watery & Wastewater Utility Date CHECKED BY'. Stormwa/ter/Utility Date CHECKED BY. 'v*� Traffic Engineer Date CHECKED BY: CHECKED BY: &Ili T ,20weoc NA- Date _ Environmental Planner Date n c d w Z o ® 3 a ® Z LL Y m $If rn N n \�01 2 O tT z g '„ Z 0 5 o ® 0 o > to n 0 m 0 N � � 4jN JOZ W FI Q >S a n U M W 0 0 in < X rn N c0 m } 0 tO o m U O w z Z 0 7 3 oz al3 0� Z 0 'W'^^ vJ Z L.L 'Q a J J W a CC W J U X W Sheet S1.00 Sheet 1 of 4 C-3 2154 n s q%r A �r•� r N rev n" r,l r- An A d 1 BARS @ 1'-6" MAX. (72) -- #4 TYPICAL) TOP AND BOTTOM OF OR AND BOTTOM SLABS (CONT.) 4'-0" H x 14'0"* W BOX t1 ,b1 #7 h1 4-6 Tt=15.0 t2,b2 #8 h2 4-6 Tb=12 w1,w2 #4 v1 4-11 TW=12.0 c 1 #7 v2 2-8 R=40 c2 #8 v3 2-8 S=1 5-6 USE "BLACK" REINFORCING, U.N.O. S = 15-6" (SKEWED) L 3" CLEAR SPAN = 14'-0" PERPENDICULAR TO WALLS WIDTH CDOT "NON-STANDARD" BOX DETAIL USCALE : N.T.S. 494CDOTBOX +. r)D + ,, rn d 1 BAR TYPICAL x Lj Q : Q z o U I =� t' to aJ w Cn J Q 2:� U J m Q � o N REINFORCING (TYPICAL) EXISTING — — ARAPET HEADWALL AND SHORE EXISTING SLAB REACHES DESIGN STRENGTH fOP SLAB REINFORCING (TYPICAL) SPAN (FT.) J BAR SIZE (#) 15-6 9 ADDED BARS AT EDGE, SKEW PARALLEL TO EXISTING FACE �OVIDE J-BAR REINFORCING IN NEW BOX ABUTTING EXIST ADDED EXTENSION NOT TO SCALE CONSTRUCTION JOINT DETAIL r FOR STAGED CONSTRUCTION SCALE : N.T.S. 494CDOTBOX GENERAL NOTES 1. ALL CONCRETE SHALL BE CDOT CLASS D (BOX CULVERT) 5000 PSI MIX. 2. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED BEFORE FRESH CONCRETE IS POURED. 3. ALL CONSTRUCTION JOINTS NOT SHOWN ON THE PLANS SHALL BE APPROVED BY THE ENGINEER. 4. THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY OF THE STRUCTURE DURING CONSTRUCTION. 5. STRUCTURE EXCAVATION AND BACKFILL SHALL BE IN ACCORDANCE WITH THESE DOCUMENTS. NO CDOT PAYMENT PROVISIONS ARE APPLICABLE, PROJECT IS TO BE BUILT ON A LUMP SUM BASIS. 6. FOR THIS CULVERT SPAN A FOUNDATION INVESTIGATION AND REPORT ARE REQUIRED BY THE CITY. 7. DO NOT BACKFILL UNTIL TOP SLAB HAS REACHED DESIGN STRENGTH, f'C. 8. SPLICE QUANTITIES FOR LONGITUDINAL AND TRANSVERSE BARS ARE NOT INCLUDED. 9. GRADE 60 REINFORCING STEEL IS REQUIRED. 10. THE MINIMUM LAP SPLICE LENGTH FOR REINFORCING BARS SHALL BE: BAR SIZE: #4 #5 #6 #7 #8 #9 #10 #11 SPLICE LENGTH: 1'-0" 1'-4" 1'-7" 1'-10" 2'-5" 3'-1" _4'-11" 4'-10" 11. ALL DIMENSIONS ARE PERPENDICULAR TO THE CENTERLINE OF THE BOX. 12. ALL TRANSVERSE REINFORCING SHALL BE SKEWED TO THE CENTERLINE OF THE BOX AS SHOWN IN 4/S2.00. 13. FILL HEIGHT IS THE DISTANCE MEASURED FROM TOP OF TOP SLAB TO TOP OF PAVEMENT. 14. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED �/4 IN DESIGN DATA: 16TH EDITION OF THE AASHTO STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES STRENGTH DESIGN METHOD UNIT STRESSES: f y = 60,000 psi., CC = 5,000 psi., LOADING DATA: LIVE LOAD = AASHTO, HS 25-44 -- USED 1.25x HS-20 LOADING DEAD LOAD CASE 1: VERTICAL EARTH LOAD = 120 LBS./CU. FT. HORIZONTAL EARTH LOAD = 30 LBS./CU.FT. DEAD LOAD CASE 2: VERTICAL EARTH LOAD = 120 LBS./CU. FT. HORIZONTAL EARTH LOAD = 60 LBS./CU. FT. FUTURE ASPHALT OVERLAY = 48 LBS./SQ. FT. LIVE LOAD SURCHARGE ON EXTERIOR WALLS = 2 FT. OF EARTH FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT e; L9� c.c �2-thv7 Mr. Michaetl). DiTullio, Manager Date Mr. Tenp trill, P.E.• District Engineer Date All changes, addendums, additions, deletions and modifications to these drawings must be approved. in writing, by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. PLEASANT VALLEY AND LAKE CANAL COMPANY Approval Block REVIEWED BY THE PLEASANT VALL Y AND LAKE CANAL COMPANY ON THIS DAY O�KfA, 200 THIS PLAT HAS BEEN SIGNED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY, BUTTHIS SHALL NOT MEAN IT APPROVES THE ENGINEERING, SURVEYING, DESIGN, CONSTRUCTION, OR OTHER PROFESSIONAL WORK. THE SIGNATURES MEAN ONLY THAT THE COMPANY HAS SEEN THE SHEETS, SIGNED, AND COOPERATED WITH THE OWNER IN PROVIDING INFORMATION. THE OWNER AND THE PROFESSIONALS IT HAS EMPLOYED ARE SOLELY RESPONSIBLE FOR THE END RESULT. ROBERT UNDERHILL, PRESIDENT City of Fort Collins, Colorado UTILITY APPROVED: Vpproval t {-City Engineer Date CHECKED BY: 9111111! Water B Wastewater Utility Date CHECKED BY: M Ai . / -I/ oP Stormwater Utility Date CHECKED BY A),+ Traffic Engineer Date CHECKED BY: ( •RB • O� e�.- PO:A0*W Lr4/4,, Date CHECKED BY: tT NT Environmental Planner Date t^ N � 2 C rM L— a U 0 W � Z s m � g� D= ® a Z M Q� cl,m SOU m z N N Z Z5 o V ®0 o j 1;� � n U s 3 0 r 0 in N 0 � w tal N J W 1- Q > W� 00 �a m N 0 m } W WW 0 m Z Z of 3 w3 of dIH �� CZ W J (� (.5U > X� 00 WMZ_ LL W C0 jW U� Sheet S2.00 C- 3 2154 v r / Cl M 1 V 1 -4" 3' CHAMFER, j" CHAMFER -CONTINUE HORIZONTAL REINFORCING THROUGH PILASTER, RE: 3/S3.00 —(6)-#7 VERTICAL W/ #3 TIES ® 12" O.C. \-" DEEP FORMED NOTCH, TYP. BRICK FACING NOT SHOWN FOR CLARITY PARAPET DETAIL ,SCALE : 3/4" = I'—D 20060630 PARAPET OETAILdw9 PARAPET DETAIL SCALE : 3/4" = 1'-0" 200606JO PARAPET DETAa.dr9 3'-4" -- -� i =� - r i a • - g----- - _i 3'-0" DUCT BANK, VERIFY IN FIELD d � a O a � 4 Q 4 Q a a e " a A O 5119,23' T/ WALL = 5122.59' T/ WALL = 5121.84' INVERT ELEV. = 5111.34, ADD (2)-//8 TOP CONTINUE TOP HORIZONTAL REINFORCING THROUGH VOIDED SLAB ADD 17 0 12" O.C. x 8'-0" BOTTOM CENTERED, TRANSVERSE ACROSS DUCT BANK " COMPRESSIBLE POLYETHYLENE RAP OVER TOP OF DUCT, TYP. FULL LENGTH VOIDED SLAB DETAIL SCALE : 3/4 = 1 -D 20060630 PARAPET 0ETAIL.dw9 0 LO v SIM 10'-7" j'-4"� 3'-10° j'-4"[ 3'-10" j'-4" ROAD SIDE RETAINING WALL ELEVATION SCALE 1/4" = 1'-0" 20060630 ELEVATIONSdwg CONTROL JOINT WITH SEALANT- SIKAFLEX SIKA-lA 10' (DESIGN HEIGHT, TYR) 1.3:1 SLOPE II'-&" LF OF RETAINING WALL 5'-2" 39'-6" 5'-2" RE. S4.00 FOR WALL AND FOOTING SIZE AND REINFORCING 16'-104" (SKEW) 12'-0" 5 2 GALVANIZED RAIL AND POSTS AS PER FORT COLLINS STANDARD, TYP. IFgt" CONTROL JOINT WITH SEALANT - SIKAFLEX SIKA-1A MAI MM III m 0 I v INVERT SIDE RETAINING WALL ELEVATION SCALE : 1/4" = 1'-0" ZI�IX BRICK VENEER TO MATCH EXISTING, TYP. -1.25:1 SLOPE MAX 11'-3g" LF OF RETAINING WALL 20060630 ELEVATIONSdw9 l T/ WALL o = 5122.59' T/ WALL = 5121.84' INVERT ELEV. = 5111.34' FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COIJANS SANITATION DISTRICT Mr. Michael E10.0briTullio, Manager Date Mr. Te atrill, P.E., District F.ngineer' Date All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. PLEASANT VALLEY AND LAKE CANAL COMPANY Approval Block REVIEWED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY ON THIS DAY OF74ft/A R 20O.7HIS PLAT HAS BEEN SIGNED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY, BUT THIS SHALL NOT MEAN IT APPROVES THE ENGINEERING, SURVEYING, DESIGN, CONSTRUCTION, OR OTHER PROFESSIONAL WORK. THE SIGNATURES MEAN ONLY THAT THE COMPANY HAS SEEN THE SHEETS, SIGNED. AND COOPERATED WITH THE OWNER IN PROVIDING INFORMATION. THE OWNER AND THE PROFESSIONALS IT HAS EMPLOYED ARE SOLELY RESPONSIBLE FOR THE END RESULT. ROBERT UNDERHILL, PRESIDENT PRESIDENT City of Fort C lins, Colorado UTILITY P proval APPROVED: T Z OV ,City Engineer Date CHECKED BY: tj.4 Water & Wastewater Utility Date CHECKED BY: & A. Stormwat�err utility Date CHECKED BY: 11JA � Traffic Engineer Date CHECKED BY: 'I W`-�P� --l`/a L. 444 MT Date CHECKED BY: NA Environmental Planner Date n b W OC Z. t V a ZQ W LL /� 2® tY� Vt OJ N `I K z Z ® C 0 O > � a E 8 c E L 3 3 3 � D0 m o I � wZ W 3 QZ jz Qh ULn W 0 0 N Q Qf E N m 0 0 m 0 o W Z �3 � 0 z N Q y d I t3 �� OZ VJ J Q W 0 In Q NaN 1\a.. Q O w in Q W J W J Sheet S3.00 C-3 2154 GENERAL NOTES 1. ALL EXPOSED CONCRETE CORNERS SHALL BE CHAMFERED 3/4". 3. REINFORCING STEEL SHALL BE GRADE Ell 2. WINGWALL FOOTINGS AND FLOOR OF BOX CULVERT SHALL BE PLACED MONOLITHICALLY. TOP OF FOOTING SHALL BE FLUSH WITH TOP OF BOX BOTTOM SLAB. LAP TO VERT BARS (C— BARS) 4. THE MINIMUM SPLICE LENGTH FOR COMMON BAR SIZES SHALL BE: AS SHOWN ON SHEET S2.00 e = I 1L I h = 10' TO 12' C] = 4'-3" b W = 9'-6° c BARS #6@12" d BARS #6@12" tf = 16" SOIL PSF = 2000 REVISED DESIGN TABLE A REVISED FOOTING DIMENSIONS AND SOIL PRESSURE FORT COLLINS-116" NTS 81 NTS ------------------- #4 ALONG TOP OF WALL ADD #4 @ 12" --� O.C. OUTSIDE FACE AT ALL WALLS 12" AND THICKER I PROVIDE 2" DIA. WEEP HOLES SHORT C — BARS EVERY 48" ALTERNATE WITH LONG C — BARS. 012 3112 " x 1112>, CONSTR. KEY 2' CLR. 1'-4" ° a as c La TYPICAL SECTION DESIGN DATA: UNIT STRESSES: f S = 24,000 PSI f c = 1,200 PSI n = 9 EQUIVALENT FLUID PRESSURE = 50 LBS./CU. FT. MAXIMUM TOE PRESSURE = 1 TON/SQ. FT. U.N.O. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED BEFORE CONCRETE IS POURED. i I' II P ° I 4" BRICK LEDGE EACH d °C FACE, RE: S3.00 C O vOi W ° EE6° W O C «aEo °��o- o y QS U ° J a 2" CLR. TO BRICK LEDGE E 'O ° O € N c u F I _ N I a #4 @ I kit 4 I � N ��VJJVVV LONG C — BARS g Zu Q°O w � o ®2 > Z Q� cn ou -- — 4" DIA. RIGID PIPE c Q � g II �IN 1'X1' CONT. GRAVEL ®� -� BEDDING IN GEOFABRIC WRAP ° O E I � d — BARS SIX #4 CONTINUOUS — m 3 WINGWALL CONCRETE SHALL BE: CONCRETE CLASS D (BOX CULVERT) 5000 PSI MIX. LIVE LOAD SURCHARGE HAS BEEN CONSIDERED. FORT COLLINS - LOVELAND WATER DISTRICT SOUTH FORT COLLINS SANITATION DISTRICT 07 Mr. TenrplTill, P.E., Distract Engineer Date All changes, addendums, additions, deletions and modifications to these drawings must be approved, in writing, by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. PLEASANT VALLEY AND LAKE CANAL COMPANY Approval Block REVIEWED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY ON TH194L DAY OF'JNF9l9^W__f l200;ITHIS PLAT HAS BEEN SIGNED BY THE PLEASANT VALLEY AND LAKE CANAL COMPANY, BUT THIS SHALL NOT MEAN IT APPROVES THE ENGINEERING, SURVEYING, DESIGN, CONSTRUCTION, OR OTHER PROFESSIONAL WORK. THE SIGNATURES MEAN ONLY THAT THE COMPANY HAS SEEN THE SHEETS, SIGNED, AND COOPERATED WITH THE OWNER IN PROVIDING INFORMATION. THE OWNER AND THE PROFESSIONALS IT HAS EMPLOYED ARE SOLELY RESPONSIBLE FOR THE �END DRESULT. ROBERT UNDERHILL, PRESIDENT City of Fort Collins, Colorado UTILI AN Approval APPROVED: ,p I Z4 og V . City EnVeer Date CHECKED BY: NIA Water & Wastewater utility Date CHECKED BY: A. I /_ Stormwater Utility lDa—te-�L=(/� CHECKED BY: _ ✓� _ Traffic Engineer Date CHECKED BY: t —OO Gr 5H7—Row6r Date CHECKED BY: &A Environmental Planner Date n } o m 0 N 0 a WOW N Q 0 3 Q r U N _w W OO V)< (ifF N H f0 0 m U O O Z � U 0' W 3 a_'Q alp o­ oz 143 g J m MF_ f. : W J U X 0 M L.LMW 0 LL W J Q Sheet S4.00 C- 3 2154