HomeMy WebLinkAboutPADS AT HARMONY - Filed CS-COMMENT SHEETS - 2007-11-28PROJECT
COMMENT SHEET
DATE: August 30, 2006
TO: Technical Services
PROJECT PLANNER: Ted Shepard
#26-06 PADS AT HARMONY — TYPE 11
Please return all comments to the project planner no later than the staff
review meeting:
September 20, 2006
Note - Please identify your redlines for future reference
❑ No Problems
❑ Problems or Concerns (see below,
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
—Plat —Site —Drainage Report —Other
—Utility —Redline Utility —Landscape
, or DMS)
LOAN�p Aoy✓'"
City of Fort Collins
6a
Number. 35 Created: 6/27/2006
[6/27/061 Engineering staff believes that Snow Mesa should be dedicated as a public street
meeting all City standards. Once accepted, the City would take over the maintenance
responsibility for this street. In order to meet the intent of the Larimer County Urban Area
Street Standards (LCUASS), which states that a public street shall terminate in a cul-de-sac,
staff would encourage the use of a roundabout where Snow Mesa intersects the circulator
drive. We feel that this would be the most ideal solution for providing the circulation and
definition at the intersection. The roundabout should be designed to accommodate fire
trucks and mobile homes. City staff does not believe that the existing pavement on Snow
Mesa would meet our current standards, and it would be the applicant's responsibility to
determine the existing pavement condition and cross-section if there is a desire to leave any
pavement in place.
Number: 36 Created: 6/27/2006
(6/27/06) The extent of the Harmony Road ROW dedication cannot be determined until a
design is completed. Harmony School Shops has dedicated about 32 feet of ROW to the
section line, and Bayer has dedicated about 40 feet. Your property will likely require
something within the range of the adjacent properties.
The easements necessary on the site will depend on the existing and proposed utilities and
drainage. Harmony Rd. does not have a standard cross-section. All pedestrian use areas,
if located outside public ROW, are to be placed in a dedicated public access easement.
If you are able to functionally tie your design into existing adjacent sites, you do not need to
provide the full 1,000 feet offstte design.
The access to this property is intended to serve both the Harmony School Shoppes to the
West and the Bayer property to the East The location of your proposed access is
acceptable with regards to the plan, but we would not support the inclusion of any additional
access points to the site, unless absolutely required by Poudre Fire Authority as a second
point of Emergency Access.
The concrete test section has been replaced.
Number. 37 Created: 6/27/2006
[6/27/06] The design considerations that we would recommend for connectivity would be to
ensure that access easements and emergency access easements are dedicated through
the private drive. Additionally, coordinate with the adjacent property owners to the
maximum extent possible to provide design solutions that work for all property owners. Staff
is willing to assist in setting up the appropriate meetings with these owners.
Department: PFA Issue Contact: Carle Dann
Topic. Fire
Number. 27 Created: 6/22/2006
16/22106] ACCESS: A fire lane is required. This fire lane shall be visible by painting and
signage, and maintained unobstructed. A fire lane plan shall be submitted for approval prior
to installation. In addition to the design criteria already contained in relevant standards and
policies, any new fire lane must meet the following general requirements: (1) Be designed
as a Oat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire
apparatus weights. Compacted road base shall be used only for temporary fire lanes or at
construction sites. (2) Have appropriate maintenance agreements that are legally binding
Page 3
Project Comments Sheet
ia S
City of Fort Collins Selected Departments
Department:
Date: September 22, 2006
Project: PADS AT HARMONY PDP - TPYE I
Issue Contact: Marc Virata
Topic: Construction drawings
Number: 16 Created: 9/19/2006
(9/19/061 The spot elevations specified for the termination of the drive aisle into Harmony
School Shops does not match the elevations called out on the Harmony School Shops plan,
the proposed elevations are 6 inches lower than what Harmony School Shops shows.
Number: 17 Created: 9/19/2006
[9/19/06] More information needs to be specified as to how sidewalk and curb and gutter of
the new Snow Mesa street section ties into existing improvement within the mobile home
community.
Number: 22 Created: 9/19/2006
[9/19/06] The Snow Mesa Drive flowline profile should show the existing "flowline" of Snow
Mesa to show how the project flowline grades ties into the existing.
Number: 23 Created: 9/19/2006
[9/19/061 The Snow Mesa Drive flowline profile shows several vertical curve designs that fall
short of standards.
Number: 27 Created: 9/19/2006
[9/19/061 On the cross sections sheet please add right-of-way information on every cross
section. Also, please add additional cross section across the Snow Mesa/Harmony
intersection (10+00, 10+50, 11+00) to better understand how the intersection works.
Number: 28 Created: 9/19/2006
[9/19/061 Eliminate the pavement thickness schedule information, or at least show the
information for private areas only as pavement design information for public right-of-way is
specified with the pavement design report.
Number: 29 Created: 9/19/2006
[9/19/06) A concrete joint pattern detail is required for the roundabout.
Number: 35
Signature
Created: 9/20/2006
Date `
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat k- Site Drainage Report Other_
Utility t' Redline Utility L'- Landscape
Page i
[9/201061 Ultimate Harmony Road designs need to be either done with the project or
approved with the Bayer project prior to sign off on the construction drawings as verification
that the setback defined on the Harmony Corridor Plan is being met and in addition, that the
curb returns, signal poles, access ramps, and sidewalks for Snow Mesa Drive are in the
proper location for the future widening. The curb return location on the northwest corner of
the Harmony and Snow Mesa intersection doesn't appear to accommodate the future third
through lane.
Number: 37 Created: 9/20/2006
[9/20/061 Please ensure that an ultimate striping plan is provided along with the ultimate
Harmony Road design and the interim striping includes the existing striping being tied into
along the frontage of the property.
Topic: General
Number: 9 Created: 9/19/2006
[9/19/06] For the roundabout design the splitter islands need to be extended past the cross
walks on the east and west movements to provide ped refuge. A splitter island also needs
to be fully created on the north leg along with a crosswalk.
- A cross
Number: 10 Created: 9/19/2006
[9/19/061 The sidewalk along Harmony Road is intended for bicycles as well as pedestrians.
Given that intention as specified in the Harmony Corridor plan, please eliminate the angular
sidewalk designs and provide a smoother pathway.
Number: 11 Created: 9/19/2006
[9/19/061 The retaining walls along the Harmony Road sidewalk are problematic if they are
above the sidewalk grade (only the easternmost wall specifies top of wall/bottom of wall
elevations) unless they are moved back 2' from the edge of walk in accordance with our
sidewalk separation requirements. Are the retaining walls throughout the development all
under 4'?
Number: 12 Created: 9/19/2006
[9/19/061 The median on Snow Mesa heading out to Harmony Road needs to be extended
past the crosswalk to provide pedestrian refuge as the crossing length of Snow Mesa
exceeds crossing length distance requirements without a pedestrian refuge island.
Number: 13 Created: 9/19/2006
[9/19/061 The amount of stacking provided for the right turn lane on southbound Snow Mesa
falls short of standards and a variance request should be provided.
Number: 14 Created: 9/19/2006
[9/19/061 The Harmony School Shops project incorporates a sidewalk along the north side
of the drive aisle that connects to the property line. This project should ideally find a way to
incorporate the sidewalk into its site design. Likewise a sidewalk is specified on one side of
the drive aisle from Front Range Village to the property line. Again, how will the sidewalk
system be continued onto this property?
Number: 15 Created: 9/19/2006
[9/19/06] In general, the plans should be showing the designs of the Harmony School
Shops and Front Range Village projects to ascertain how the project fits in context with the
Page 2
two other projects. Also, how does the project fit with the mobile home park community to
the north?
Number: 18 Created: 9/19/2006
[9/19/06] There appears to be a small section of sidewalk that falls outside of the platted
boundary at the northeast quadrant of the roundabout that should be in right-of-way or
access easement.
Number: 19 Created: 9/19/2006
[9/19/061 What sort of legal right is already in place or needs to be secured for the
construction of Snow Mesa north of the platted boundary of the site?
Number: 20 Created: 9/19/2006
[9/19/061 The additional widening of Harmony Road shows construction within Front Range
Village property (until such time as the plat if filed for Front Range Village with additional
Harmony Road right-of-way dedication).
Number: 21 Created: 9/19/2006
(91191061 In conjunction with the two previous comments, letters of intent appear required
from the mobile home park community and the Front Range Village developer for offsite
construction.
Number: 30 Created: 9/19/2006
[9/19/06] The interior of the roundabout may be landscaped only. The use of statues and
other "art" won't be allowed as we do not wish to promote pedestrians from visiting the area.
Number: 36 Created: 9/20/2006
(9/201061 The 80' setback requirement of the Harmony Corridor Plan appears to be adhered
to east of Snow Mesa Drive, although there are several patios that encroach within the
setback. The 80' setback west of Snow Mesa Drive I'm not clear on due to the lack of
interim/ultimate striping information. I'll defer to Planning on whether the patio
encroachments into the setback require some sort of modification, variance, etc.
Number: 40 Created: 9/22/2006
[9/22/061 Our Pavement Management Engineer notes that the site has high swell soils and
mitigation will be required in the pavement design for Snow Mesa.
Topic: Plat
Number: 26 Created: 9/1912006
[9/19/061 The 9' utility easement corridor is not being maintained along the west side of
Snow Mesa with the building envelope #4 shown on the plans.
Number: 39 Created: 9/22/2006
[9/22/061 Technical Services comments are attached with Engineering redlines.
Page 3
Selected Issues Report
(;1, of Pori Catlin%
Date:
4/4/2008
PADS AT HARMONY PDP - TYPE I
SELECTION CRITERIA: Status = All
6'II04.5
Department: Traffic Operations Issue Contact: Eric Bracke
Topic: Traffic
Number:2 Created:9111/2006 Pending
[9/111061 1 have requested additional information regarding the saturation flow rates used
for Harmony Road in the TIS.
More to follow.
Department: Transportation Planning Issue Contact: Kurt Ravenschlag
Topic: General
Number:31 Created:9/19/2006 Pending
[9/19/06] Place any public sidewalk that is not in ROW in a Ped Access Easement (i.e.
along Harmony Rd.)
Number:32 Created:9/19/2006 Pending
[9/19/06] Be sure to conveniently locate bike parking for all buildings.
Number:33 Created:9/19/2006 Pending
[9119/06] May want to locate HC parking in front of building containing medical office space.
Number:34 Created:9/19/2006 Pending
[9/19/06] Repeat engineering comment Vs: 9, 10 12, and 14
Page 1
PROJECT
COMMENT SHEET
r,
DATE: August 30, 2006
TO: Engineering Pavement
PROJECT PLANNER: Ted Shepard
#26-06 PADS AT HARMONY - TYPE II
Please return all comments to the project planner no later than the staff
review meeting:
September 20, 2006
Note - Please identify your redlines for future reference
Q No Problems
Problems or Concerns (see below, attached, or DMS)
,� : t I be R Pf o-W14 ; N 4e pac,e,.. ^4/
G!2 Z G
Name (please
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
_Plat _Site _Drainage Report _Other
_Utility _Redline Utility _Landscape
6a
C3tp of Fort Collins
Citvof Fort Collins
Current Planning
DATE: August 30, 2006
TO: Engineering
PROJECT
COMMENT SHEET
PROJECT PLANNER: Ted Shepard
#26-06 PADS AT HARMONY — TYPE II
Please return all comments to the project planner no later than the staff
review meeting:
September 20, 2006
Note - Please identify your redlines for future reference
❑ No Problems
❑ Problems or Concerns (see below, attached, or DMS)
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
_Plat _Site _Drainage Report _Other
_Utility _Redline Utility _Landscape
City of Fort Collins Review Staff
281 N. College Avenue
Fort Collins, CO 80521
Ref; Pads at Harmony Response to Comments
Issues:
Engineering
#6 Standard utility plan submittal requirements will apply.
Completed
#7 Subdivision plat must be completed.
Completed
#8 Street oversizing fee will apply.
Completed
#9 Larimer County road impact fees will apply.
Completed at time of building permit
#10 Transportation Impact Study required at PDP
Completed
#11 Dedication of right of way for East Harmony Road.
Completed- see plat
#12 This development will be responsible for the repair and replacement of
damaged curb, etc. if any exists.
Future determination
#13 Public Improvements built to LCUASS standards.
Completed- see civil drawings
#14 A Development Agreement will be required.
Currently being finalized.
#15 Development will be responsible for under -grounding of any existing overhead
utility services that are property.
Working with City staff on this issue.
1136 East Stuart Street, Suite 2040 Fort Collins, Co. 80525 ■ Phone: 970-472-8954
Fax: 970-472.8955 ■ iandimaoesafni.com ■ www.landimaaesinc.com
ds P
#16 Repayment of traffic signal.
Working with City staff and adjoining property owners.
#17 Development is responsible to repay improvements to Harmony Road.
Working with City staff.
#18 East Harmony Road is no longer a CDOT roadway.
Understood.
#19 Improvements to Snow Mesa Drive are necessary.
Completed- see civil and site plans. Striping and necessary improvements have
been designed with adjoining properties and a traffic circle proposed north of
Harmony Road. Continuing to work with City staff.
#20 A drive connection to property to the west.
Completed- see site plan
#26 Transportation Development Review Fees will apply to this project.
Completed
#34 Repay of traffic signal at Snow Mesa and Harmony Road.
Working with City staff and adjoining property owners.
#35 Dedication of Snow Mesa Drive as a public road.
Completed- see plat.
#36 Tieing right of way into Harmony School Shops and Bayer properties to the west
and the east respectively.
Completed- see plat.
#37 Access easements and emergency access dedicated through private drive
Completed- see plat and site plan.
#27 A fire lane is required.
Completed- see plat and site plan.
#28 Fire hydrants must be the type approved by water district.
Completed- see civil drawings.
#29 Automatic fire sprinklers.
Will be completed with architecture design.
#31 Knox box to be mounted at each building.
Will be completed with architecture design.
#32 Address numerals shall be visible from street fronting the property.
Working with City staff and will be completed with architecture design.
#33 Commercial cooking and automatic fire extinguishing systems.
Will be completed with architecture design.
#21 Water quantity or quality detention.
Working with City staff and the property owners to the east, but additional small
detention ponds have been added within the Harmony Road bufferyard. See civil
drawings.
#23 Information on existing water/sewer mains has been provided previously.
No additional comments.
#24 Water main loop must be looped through the site from the Harmony School
Shops to the Bayer site.
Completed- see civil drawings.
#25 Sewer connections to Harmony School Shops and to Harmony Mobile Home
Park.
Working with City staff and adjoining property owners.
#1 Neighborhood sign district.
Will be completed with or prior to architecture design.
#2 Designation of Basic Industrial and Non -Retail Activity Center.
Working with City staff and will be addressed with modification.
#3 Need to plat property.
Completed- see plat.
#4 Light intrusion from a commercial center into the mobile home park.
Working with City staff and adjoining property owners. The lighting design was
conscious of the delicate nature necessary to satisfy the neighbors and City
requirements. See narrative and lighting plan which is not able to take into account
the existing mature cottonwoods and the additional landscaping being added by this
development.
#5 The two handicapped parking spaces should be moved closer to the building.
Completed- see site plan.
#1 Current Planning- Retail center and modification to Land Use Code.
Working with City staff, adjoining property owners and will be addressed with
modification proposal.
#2 Current Planning- Parking limited to 5 spaces per 1000 s.f. of leasable area on
eastern parcel designated as Neighborhood Commercial Shopping Center.
Completed- Working further with staff to clarify necessary modifications.
#3 Current Planning- Reluctant to support modification to the 80 foot setback along
Harmony.
Working with City staff. Lot depth and economics are the main issues with this
modification. Please see Project Description for further details.
#4 Current Planning- Connecting walkways along Harmony Road.
Completed- see site plan.
#5 Current Planning- Neighborhood meeting required.
Completed.
#6 Current Planning- Landscaping should provide screening for cars in bank drive
thrus.
Completed- Special attention was paid to bank drive thrus as well as service areas.
Approximately 15% additional landscaping has been added due to modification to
setback.
#7 Current Planning- Architectural elevations
Working with City staff and architects currently.
412.4gS5
RECEIVEI)
w
STAFF PROJECT REVIEW duN 3 0 nos
V ME
GINO CAMPANA
BELLISIMO INC Date: 06/28/2006
3702 MANHATTAN AVE #201
FORT COLLINS, CO 80526
Staff has reviewed your submittal for HARMONY ROAD AND SNOW MESA DRIVE
PRELIMINARY DESIGN REVIEW, and we offer the following comments:
ISSUES:
Department: Engineering Issue Contact: Dan DeLaughter
Topic: General
Number. 6 Created: 6/21/2006
[6/21/061 The standard utility plan submittal requirements will apply to this development.
Number. 7 Created: 6/21/2006
[6121/06] A subdivision plat must be included as part of the PDP submittal documentation
because this property has not previously been platted.
Number. 8 Created: 6/21/2006
[6/21/061 Street oversizing fees will apply to this development request The fees are based
on vehicle trip generation for the proposed land uses in the development plan. Please
contact Matt Baker in Engineering at 224-6108 for detailed information on the fees. The
fees will be collected at the time of issuance of building permits. Please note that, as with all
fees, the Street Oversizing Fee may be adjusted on an annual basis.
Number. 9 Created: 6/21/2006
[6/211061 The Larimer County Road Impact Fees will apply to development no this property.
This fee is collected by the City of Fort Collins at the time of building permit issuance.
Number 10 Created: 6/21/2006
16/21/061 A Transportation Impact Study (TIS), addressing all modes of transportation, will
be required with your PDP submittal. Please contact Eric Bradte of the Traffic Operations
Department at 224-6062, and Kurt Revenschlag of the Transportation Planning Department,
at 416-2040, to determine what information will be needed in the TIS pertaining to Level of
Service (LOS) for vehicle, pedestrian, bicycle, and transit modes of transportation.
Number. 11 Created: 6/21/2006
16/21/061 This property will have to dedicate additional street right-of-way (ROW) for East
Harmony Rd. Also, the necessary easements (utility, drainage, emergency access, etc.)
behind the ROW must be dedicated with the subdivision plat.
Number. 12 Created: 6/21/2006
[6/21/061 This development will be responsible for the repair and replacement of any
damaged curb, gutter, and sidewalk along its street frontages, if any exist.
Number. 13 Created: 6/21/2006
[6/21/06] Any public improvements must be built according to the requirements set forth in
the Larimer County Urban Area Street Standards (LCUASS). Please familiarize yourself with
Page 1
Appendix Ell, the complete construction documentation. Checklist, in LCUASS as this
development request will be subject to the requirements.
Number: 14 Created: 6/21/2006
16/21/06] A Development Agreement (DA) and a Development Construction Permit (DCP)
will be required for development on this property.
Number. 1 S Created: 6/21/2006
[6/21/061 Development on this property will be responsible for the under -grounding of any
existing overhead utility services that are along or on this property. An overhead utility line
was moved to install the signal at the intersection. This project should underground or, at a
minimum, provide conduit for future under -grounding.
Number. 16 Created: 6/21/2006
(6/21/061 Development on this property will be responsible for a repay for the traffic signal
that was recently installed at the intersection of Fast Harmony Road and Snow Mesa Drive.
Number. 17 Created: 6/21/2006
[6121/06] Development on this property will be responsible for a repay for any necessary
improvements to Harmony Road. This includes the dedication of ROW and the design and
construction of the Improvements, plus the design of improvements for 1,000 feet off -site in
both directions (east and west). Please coordinate with Stantec, the consulting engineer for
Bayer Properties, as to how much of this design has been done so far.
Number. 18 Created: 6/21/2006
16/21/06] East Harmony Road is no longer a Colorado Department of Transportation
(COOT) roadway. The access control plan still applies, but it is now under the City of Fort
Collins standards for design.
Number. 19 Created: 6/21/2006
16/21/06] Improvements are needed to Snow Mesa Drive. Development on this property
will be responsible for a reconfiguration of the access so that it works better, i.e. has an
adequate left turn lane, a pedestrian crossing, and a pedestrian refuge if a median is used.
Number. 20 Created: 6/21/2006
[6/21/06] A drive connection from the parking area in this development to the undeveloped
property to the west is needed.
Number. 26 Created: 6/21/2006
(6/21/061 Transportation Development Review Fees (TORF) will apply to this project and will
be due at the time it is submitted for review. A TDRF application is available online at
http:/twww.fcgov.com/engineering/dev-review.php
Number: 34 Created: 6/27/2006
[6/27/06] The newly installed signal at Snow Mesa and Harmony was paid for by the
Developer to the south. It is the applicants responsibility to determine whether or not a
repay has been filed for the cost of the signal. The existing signal is intended to serve the
existing conditions, but it may not be suitable to accommodate acceUdeccel lanes,
landscaping and sidewalk necessary on your frontage. This will be a determination made
when the project is submitted and we are able to review the design of Harmony.
Page 2