DATE: August 10, 2005
TO: Trans. Planning
PROJECT PLANNER: Ted Shepard
#1-95F New Belgium Brewery, Packaging Hall PDP &
Amended ODP — Type II
Please return all comments to the project planner no later than the staff
review meeting:
August 31, 2005
Note -Please identify your redlines for future reference
❑ No Problems
Problems or Concerns (see belo-w-)or attached)
too �
C"N4 ��f, �<� �SSdK—rYY.t� %]C."2L�✓l� ''Y' �Y/ti
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat -bite _Drainage Report _Otherft
ytJtility S`Redline Utility Landscape City of Fort rt Co
STAFF PROJECT REVIEW
Cityof Fort Collins
BHA DESIGN, INC. Date: 02/06/2006
LUKE OLDENBURG
4803 INNOVATION DR.
FORT COLLINS. CO 80525
Staff has reviewed your submittal for NEW BELGIUM BREWERY, PACKAGING HALL &
BUCKINGHAM ST PDP & AMENDED ODP - TYPE II, and we offer the following comments:
ISSUES:
Department: Engineering Issue Contact: Marc Virata
Topic: Buckingham Street Plans
Number: 41 Created: 9/13/2005
[1/30/06] The cover amount with the HERCP pipe is still not per standards however it is
acknowledged that the amount will be acceptable given the constraints.
[12121/05] The profile sheet for the Coy Ditch does not show a proposed grade line to see if
this issue was resolved.
[9/13/05] The amount of cover over the crossing in which the realigned ditch ties into is less
than standard. That combined with the structure being corrugated metal raises a general
concern. We would want to see the corrugated metal pipes removed and replaced with twin
elliptical pipes (RCP?) to achieve better cover and provide a pipe type that is to standard.
Number: 44 Created: 9/14/2005
[1/30/06) Carried over for reference.
[9/14/05] At time of final plan, provide cross sections along Buckingham Street at 50'
intervals.
Number: 46 Created: 9/14/2005
[1130/06] Carried over, appears to be unresolved.
[12/21/051 Appears to be unresolved. With the curb extensions, this information is needed
[9/14/05] Provide flowline curve/line table data for verification. The inset parking narrowing
appears fine bt I'd like to see the radii specified just to be sure.
Number: 93 Created: 1/30/2006
[1130/061 Clarify the inlet types proposed along Buckingham Street as area inlets are
specified where Type R appear to be intended.
Number: 94 Created: 1/30/2006
[1/30/06] Please look at tweaking the curb extension design for the north side of
Buckingham Street across from First Street such that the curb extension is brought further
east (about 10-15 feet) to better address pedestrian crossings on the east side of the
intersection.
Number: 95 Created: 1/30/2006
[1/30/061 The street repair limits shown with the signing and striping plan shows that the
patching limits will need to be expanded as the eastbound through lane does not match up
with the patching limits. Please expand the patching limits.
Number: 96
Created: 1/30/2006
Page 1
[1/30/061 Provide for at least one access ramp along the north side of Buckingham Street
for each intersection with First, Second and Third Street. Only one access ramp is needed
at T-intersections.
Topic: General
Number: 27 Created: 9/2/2005
[1/30/06] Carried over for reference as unresolved.
[12/21/05] Appears to be unrevsolved.
[9/2/05] A letter of intent is required from the Coy Ditch Company for the work proposed by
the development.
Number: 83 Created: 12/28/2005
[1/30/06] As it was brought up in staff reivew that the design is being further refined to
possibly avoid any potential conflicts, the comment is being carried over for review at time of
final.
[12/28/05] The storm sewer manholes behind the curb along Buckingham Street appear to
be partially in the Buckingham sidewalk; there needs to be a separation from the sidewalk
as prescribed in Figure 16-1 of LCUASS.
Number: 90 Created: 1/30/2006
(1/30/061 The creation of the temporary detention pond on the south side of Buckingham
Street requires the responsibility of frontage improvements for Buckingham and First Street
abutting the pond per 24-95 of the City Code. This item will need more discussion after
hearing and as discussion continues with the Bohemian Foundation.
Topic: Plat
Number: 29 Created: 9/2/2005
[1/30/061 Carried over for reference as unresolved. The creation of an "irrigation easement"
on the plat is problematic as the certificate of dedication has noted that easements shown
are dedicated to the City and the Coy Ditch is mainly a private system.
[12/21/051 Appears to be unresolved. The plat shows an irrigation easement while the
certificate of dedication states easements are conveyed to the City and the irrigation line is
not the City's.
[9/2/05] The plat indicates an "irrigation easement" which appears to be dedicated with the
plat. As the dedication statement dedicates all easements to the City, it appears this ditch
easement should be indicated otherwise. More than likely, an easement will need to be
dedicated to the Coy Ditch Co. by separate document, with the recording information
provided on the plat.
Number: 91 Created: 1/30/2006
[1130/061 For ease of specifying obligations onto the property set forth in a development
agreement, we'd still prefer creation of a lot line to coincide with the limits of development
line specified on the documents.
Number: 92 Created: 1/30/2006
[1130/06] Technical Services provided the following comments:
- Show Buckinghman right-of-way in the same manner as the 3rd Filing.
- A monument is needed at intervals not to exceed 1400'
- What is "(R1)"?
- Bearing and distance information is missing at the First Street intersection.
-An area is drawn but isn't indicated along Linden Street.
Page 2
/-;-� FINAL PLAN
� COMMENT SHEET
City of Fort Collins
Current Planning
DATE: March 15, 2006
TO: Trans. Planning
PROJECT PLANNER: Ted Shepard
#1-95F/G New Belgium Brewery, Packaging Hall &
Buckingham St PDP & Amended ODP & Final
Plans — Type 11
Please return all comments to the project planner no later than the staff
review meeting:
April 12, 2006
Note -Please identify your redlines for future reference
No Problems
❑ Problems or Concerns (see below or attached)
Name (please print)
CHECK HERE
��IF��YOU WISH TO RECEIVE COPIES OF REVISIONS
_Plat mite _Drainage Report _Other
_Utility _Redline Utility _Landscape