HomeMy WebLinkAboutWESTBROOK PUD - Filed GC-GENERAL CORRESPONDENCE - 2005-08-25Develor, ent Services Engineering Department 7/2e/92 Mr. Dick Schmidt Schmidt Earthbuilders, Inc. 621 Sherry Drive Ft. Collins, CO B0524 Dear Dick: Pursuant to your request, this letter requirements for compaction over the Westbrooke P.U.D., first filing. is to document the city's sewer service to lot 26 at As you are aware, when the curb, gutter, and sidewalk was placed, the end of the 4" sewer service was found to be approximately 1 foot under the sidewalk,at a depth of approximately e feet below finished grade. It has been our observation that due to the placement of the marker that compaction at the ends of services is seldom achieved,and it is our belief that the trench was not adequately compacted directly over the pipe's end (below the sidewalk), and for an unknown horizontal distance back toward the sewer main. Evidence of this lack of compaction was plainly visible in the excavation, and our records do not indicate compaction tests were taken in this part of the trench. Because of the likelihood of future failure due to the conditions described above, the City of Ft. Collins will not accept this or related portions of the improvements on Shadowbrooke Ct. until resolution of the problem has been assured. As we discussed in the field, two options available to you would be to excavate below the curb, gutter, and walk to a point of known compaction, then backfill with a "Flowable Fill" type product, or to remove the curb, gutter, and walk, then excavate and recompact the trench using conventional methods. If you have an alternate method which will assure proper compaction for the area in question, we are certainly willing to consider it. Please contact our office at 221-6605 with any questions concerning this matter. Thank you. Sincerely, City of Ft Collin ✓� -- Tom Chapel Construction Inspector cc:P & B Partnership Dave Stringer Project File 281 .North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6605 Services Engineering Department September 21, 1992 Mr. Dick Pitner P & B Enterprises 375 East Horsetooth Fort Collins, CO 80525 RE: Westbrooke P.U.D., 1st Filing, Phase 1A, 1B Dear Dick: This letter is to inform you that improvements at Westbrooke P.U.D., 1st Filing, Phase IA have been inspected and will be initially accepted upon completion of the following: o As -Constructed Drawings still need to be submitted and approved before water and sewer improvements can be accepted. As we discussed, the two year warranty will not begin until these have been approved. o Inlet filters need to be installed on the east side of Westbrooke Court and the north side of Wakerobin. Improvements at Westbrooke P.U.D., Phase 1B have been inspected and will be initially accepted upon completion of the following: o As -Constructed Drawings need to be submitted and and approved before water and sewer improvements can be accepted. o Sidewalk needs to be completed along Seneca Street. o The fire hydrant at the north end of Shadowbrooke Court leaks and needs to be repaired or replaced. As these individual items are completed, they need to be inspected so that they can be accepted and the warranty period can begin. Please be advised that additional deficiencies may arise as a result of construction and will need to be addressed as they occur. Please contact me at 221-6605 should you have any questions or concerns. Sincerely, Tom Chapel Engineering Construction Inspector TC/ltg cc: Schmidt Earthbuilders CG&S Concrete _RI \ nth C-nlL,ge .Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • 003) 221-han; fPARSONS & a ASSOCIATES CONSULTING ENGINEERS December 1.1, 1991 Mike Her2.ig City of Fort Collins 218 Nort:i College Aver.nc Fort Col__,.ns, CO ,052-- RE: Westbrooke pavir:c, ri�cng _s Dear MikE: The typical sectjc:,s for the Westbrooke P.U.D. First Filing reflected preliminar,2 ils information completed prior to the completion of final _ �ad�;a,. alignments. We have submitted the final alignments to Er:p.re laboratories and they have adjusted the street sections bass oa ._.is-_aformation. I have attached a=1ettsr from Empire Laboratories outlining a chPn,:Te in street sections *.:0 3" of asphalt on 9' of base material for Westbrooke Court ant' ',c tbrooke Drive and 3" of asphalt on 8" of base material for snadowbrooke Court and Hill Creek Court. 1 have also attached Westbrook,- construction plans which reflect these ch=.noes. W� that i.nes _.ctions more accurately reflect actual .�1 co.Iditions aT� r«„"-=t you. approval of the revised street or.s. case feel fr,,__ _c contact me should you have additional auestj_ons. Sinert l , L coLch, P E .:_n�-or Engineer J FdC/abl Enclosures cc: Chuck Betters, The Group, Inc. �., . _. ,__titfors