HomeMy WebLinkAboutEMIGHS REPLAT - Filed CS-COMMENT SHEETS - 2005-08-10PROJECT
COMMENT SHEET
Citp of Fort Collins
Current Plannint
DATE: January 16, 1998 DEPT: Engineering
PROJECT: 430-97 200-220 W. Prospect Rd. (Vinni's Pizza), (Emigh's Subdivision,
Lots 30 & 32) Type II (LUC)
PLANNER: Ted Shepard
ENGINEER: Michael K. Dean
All comments must be received by: 1/15/98
UTILITY PLAN COMMENTS
Dedicate a 9 foot Public Access Easement from the existing R.O.W. to the back of sidewalk, provide a legal description and
exhibit.
Provide necessary spot elevations on utility plan to show drive entrance and ADA ramps. -
Provide detail of roof drain to allow for drainage to the parking lot from the SE comer of the 220 W. Prospect building.
Replace the existing area inlet with a Type R curb opening inlet to better accommodate drainage from the new curb and gutter. —
The on -site parking lot will need to drain to W- Prospect, provide a curb cut and sidewalk culvert at the low point in the
parking lot.
SITE, & LANDSCAPE PLAN COMMENTS
Provide striping details for crosswalk, {Paad, and arrows.
Show irrigation taps aaA+ktmi a for landscape strip and parkway.
-Add the following notes to the landscape plan. Locate all utilities prior to any planting and maintain the following
separationsTrees-10' to all water and sewer lines, Shrubs - T to all water and sewer lines.
Date: 1 to
Signature:
PLEASE SEND COPIES OF MARKED REVISIONS: ❑ PLAT
[� SITE
[� UTILITY
(] LANDSCAPE
PROJECT
COMMENT SHEET
City of Fort Collins
Current
DATE: November 5, 1997 DEPT: Engineering
PROJECT: #30-97 200-220 W. Prospect Rd. (Vinni's Pizza), (Emigh's Subdivision,
Lots 30 & 32) Type II (LUC)
PLANNER: Ted Shepard
ENGINEER: Michael K. Dean
All comments must be received by: 11/19/97
GENERAL COMMENTS
Provide necessary spot elevations on utility plan to show drive entrance and ADA ramps.
Parking set back of 50' is required, as per table 5 of the Standards four of the proposed parking spaces
are not in compliance, eliminate the spaces or request a variance.
Looking at proposed layout it is possible to meet minimum dimensions on parking stalls and drive and
provide a standard 10' parkway strip adjacent to W. Prospect as per standard D-1-b.
Sidewalk appears to be outside of City R.O.W. provide public access easement for this area.
Show Radii at drive entrance curb returns, concrete shall extend to R.O.W..
Provide striping details for crosswalk, island, and arrows.
Show irrigation taps and plumbing for landscape strip and parkway.
Show locations of utilities and check against plant note 11.
Date: /09 91 Signature: ���--
A,0,0/T101✓AC COm/Nr.V7S O.v 141/P$
PLEASE SEND COPIES OF MARKED REVISIONS: ❑ PLAT
SITE
ff�UTILITY
LANDSCAPE