COMMENT SHEET
DATE: 20 June 1995 DEPARTMENT: %�nc�lMWjc
PROJECT: 80-83C WEST SWALLOW PUD, Lot E - Final
PLANNER: Mike Ludwig
All comments must be received by: Friday, 30 June 1995
❑ No Problems
X Problems or Concerns (see below)
PLAT -
• A 9 FOOT UTILITY EASEMENT IS NEEDED ALONG BOWIE AVE NOT 6 FOOT.
• NORTHWEST CORNER IS NOT INDICATED TO BE A DRAINAGE EASEMENT AS THE OTHER
AREAS ARE - DOES IT NEED TO BE?
• A GENERAL 9 FOOT UTILITY EASEMENT IS NEEDED ALONG W. SWALLOW RD IN ADDITION
TO THE SEWER EASEMENTS.
• A 9 FOOT UTILITY EASEMENT LABEL EXISTS ON THE FAST SIDE BUT NO LINE IS
PRESENT.
UTILITY PLANS -
COVER -
-*(CONTINUED ON NEXT PAGE)
Date:/in1 Signatur y
1 /
CHECK IF YOU WISH TO RECEIVE ❑ PLAT
COPIES 01: REVISIONS: ❑ SITE
LANDSCAPE
UTILITY
COMMUNITY I'L.ANNING and
ENVIRONMENTAL SERVICES... 281 NORTH COLLEGE, P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750
CURRENT PLANNING DEI'ARINIENT
• ADD "SANITARY SEWER, STORM SEWER, WATERLINE TO NOTE I NOTES 2 AND 3 ARE
OK, BUT STILL NEED REFERENCE TO 3 YR RE -REVIEW CLAUSE.
• CORRECT NOTE 8 TO MEET STANDARD LANGUAGE.
• ADD NOTE I t3 REGARDING NOTIFYING ENGINEERING AND EROSION CONTROL INSPECTOR.
SHEET 2 -
• INDICATE THE. PROPERTY LINE BOUNDARIES AND SHOW EASEMENT LINES
• INDICATE THE. CENTERLINE RADIUS OF THE SIDEWALK WHERE IT JOGS. MIN RADIUS
ALLOWED 60 FEET
• THE SIDEWALK TO THE EAST AND SOUTH, IS IT EXISTING? IF SO SHOW AS EXISTING
SHEET 6 -
• CLARIFY SIDEWALK DETAIL. SEE PLANS
• PROVIDE DETAIL D-20 IF CONNECTING TO EXISTING SIDEWALK
7o(J -rIJ