Loading...
HomeMy WebLinkAboutSOUTH RIDGE GOLF CLUB CART STORAGE - Filed BDR-BASIC DEVELOPMENT REVIEW - 2010-05-18DBL STUD GLUED & cnr•u ueu ED PER VOTES O.C. c uoc ,vniLING" EA SIDE OF PLY JOINT SECTION A=A TYPICAL DOUBLE STUD AT SHEATHING EDGE WALL B" - SEE PLAN "EDGE NAILING" EA SIDE OF PLY JOINT r OL ,v ,L„vJ" EA SIDE OF PLY JOINT STAGGERED SECTION B-B TYPICAL SINGLE STUD AT SHEATHING EDGE ra NOTE: WHERE NEW HOLD DOWNS ARE INSTALLED ON EXISTING WALLS USE SISTER STUD AS REQUIRED TO BUILD UP BOUNDARY STUD TO MIN. 3x THICKNESS NAIL SISTER TO EXISTING STUD WITH 2O-16d NAILS ® 4" STAGGERED FOR HD5 40-16d NAILS ® 3" STAGGERED FOR HD7 2x4 BLOCKING SECTION C-C TYPICAL HORIZONTAL SHEATHING EDGE 8d AT 12" O.C. AT PLY BLOCKING HOLD DOWN SEE ARCHITECTURAL ALL PLYW01 PIECE IN STUD ABOVE HOLD DOWN BOUNDARY ELEMENT EDGES A FOR DRY WALL ATTACHEMENT SEE PLAN -MIN 4x ADD STUD HOLD DOWN 16d ® 4" STAGGERED ® SILL PLATE BOLTS - SEE SCHED. BOUNDARY NAILING WALL "B" „ R— SOLID BOUNDARY STUD WITH SAME NOMINAL DIMENSIONS WALL AS WALL STUDS BOUNDARY NAILING WALL "A" TYP WALL INTERSECTIONS SCALE : 1" = 1'-0" SHEAR WALL BOUNDARY NAILING TYPICAL END 3940Ta6 TYPICAL MINIMUM NAILING REQUIREMENTS PER 1997 UNIFORM BUILDING CODE TABLE 23-11-B-1 WHERE INDICATED CONNECTION COMMON NAILS PER 1. 1 "x6" subfloor or less to each joist, face noil 2-8d UBC 9 2. Wider than 1 x6" subfloor to each joist, face nail 3-8d UBC 9 3. 2" subfloor to joist or blocking, blind and face nod 2-16d UBC 9 4 Sale late to joist or blocking, face nail 16d®16" UBC 9 5. To late to stud, end nail 2-16d UBC 9 E Stud to sole plate 4-8d toenail or 2-16d end nail UBC 9 7. Double studs, face nail 16d®24 UBC 9 8. Double top plates, face nail 16d®16" UBC 9 9. Top plates, laps and intersections 2-16d UBC 9 1D Continuous header, two pieces 16d016" o.c. alongeach ed e UBC 9 11. Ceding joists to plate, toenail 3-8d UBC 9 12 Continuous header to stud, toenail 4-gd UBC 9 13 Ceiling joists, laps over partitions, face nail 3-16d UBC 9 14. Ceiling joists to parallel rafters, face nail 3-16d UBC 9 15. Joist or rafters at all bearings, toenails each side 2-10d 16 1 " brace to each stud and plate, face nail 2-8d UBC 9 17. 1 "x8" sheathing or less to each bearing, face nail 2-8d UBC 9 18. Wider than 1 "x8" sheathing to each bearing, face nail 3-8d UBC 9 19. Built-up comer studs 16d®24" ox, UBC 9 20. Built-up girder and beams 20d®32" o.c. at top and bottom and staggered 2-20d at ends and at each splice UBC 9 21 2" planks 2-16d at each bearing UBC 9 2. Bridging to joist, toenail each end a. Blocking betweeen joists and rafters To joists or rafters - Toenails each b Blocking between studs, each end 2-10d side, each end -2-10d toenails or 2-16d 23. Plywood sheathing See typical wood panel shear wall construction detail TYP MIN NAILING SCALE : NTS REQUIREMENTS 394DT05 8d ® 4' PL) 2x4 BLOCI 18go STRf AT WINDOW 10d ® 4" MI ^ONT. HEADER, )E NAIL TO ATE w/ 16d 6" EA. SIDE -2"x PLATE WIND STUD` E SET BETWE IACENT OPEN ARING STUDS SCHEDULE OPTIONAL DETAILS AT MULTIPLE OPENINGS SECTION D-D TYPICAL BLOCKING AT WINDOW STRAP STUD TYP SHEATHING 4DE C 0 C-C CONIINUL SHLAIHING rruvuurr TO FDN SILL PLATE OPENING CONCEPTUAL SHEATHING LAYOUT A AT SHEAR WALL TYPE A DESIGN CAPACITY = 350 PLF SHEAR WALL DETAIL SCALE 1/2" = 1'-0" I --- --- - - - -- -- _ 71;-- ---- --------- I ZONE 1 ZONE II ZONE I 1 I � I I ' � � I I I I I I I ' NAILING ZONE SHEAR BLOCKING BOUNDARIES CENTER 1 260 PLF YES 8d®4" O.C. 8d®12" O.C. 11 180 PLF NO 8d®6" O.C. 8d®12" O.C. ROOF DIAPHRAGM CONN. KEY SCALE : 1/8" = 1'-0 394DTXX 394DT09 BRICK VENEER UP TO 3'-8" AFF - HORIZONTAL WOOD SIDING ABOVE 3'-8" ATE 2x6 WOOD STUDS 0 16" O.C. ROOF PLAN NOTES 1. Typical roof is 3/4" plywood over 2x or LVL rafter. 2. Nail plywood to rafters with 8d nails at 6" o.c. edges and 12" o c , intermediate. 3 Typ. wood column is 3-port Hem -fir No.2 glued and nailed together, u.n.o. 4. Install 2-2x6 each side of header for openings greater than 4'-0", u.n.o. 5 See S1.1 for General Notes. 6 See S1.1 for Load Keys. 7. See S2 1 and S2 2 for Typical Details. SINGLE OPENING SPAN LVL ALTERNATES DIMENSIONED LUMBER ALTERNATES NO. OF BEARING ,T LIDS REMARKS DOUGLAS FIR 3'-0" (2) 1 / "x7 / " or (3) 1 / "x5 /p" (2) 2x 12 or (3) 2x 10 1 4'-0" (2) 1 /4 "x9 / " or (3) 1 / x7 / " N/A (3) 202 1 -- 5'-0" (2) 1' x11 /q"or(3) 114 x9/4" N/A N/A 2 -- 6'-0" (2) 114"xII /8"or(3) 1 /4"xII / N/A N/A 3 - 7'-0" (2) 11 "x14" or (3) 1 /4"xII / N/A N/A 3 -- 8'-0" (2) 1 3 "x16" or(3) 1 /4"x14" N/A N/A 3 -- 9'-0""x18" or(3) 1/4"x16" N/A N/A 3 0' NIA N/A (3) 1 /4"x16" N/A N/A 3 -- NOTES. A. HEADERS DESIGNED FOR 3800 PLF DEAD + SNOW LOAD B. TIMBER HEADERS TO BE No.1 DOUG-FIR C. LVL = LAMINATED VENEER LUMBER D. LVL HEADERS Fb=2600 PSI E HEADERS SUPPORTING POINT LOADS FROM BEAMS OR COLUMNS SHOULD NOT BE SIZED FROM THIS TABLE NOTIFY STRUCTURAL ENGINEER GL" REPLACEMENT OPTION LVL DEEPER GLU-LAM WIDER GLU-LAM (2) 1'3/4xl4" LVL 3V8"x18" 5V8"x13V2" (3) 13/4xl4" LVL 5%8"r16%2" 6'3/4"x15" (2) 13/4x1171 LVL 3%"x15" 5%"x12"__ (3) 13/4x11 %8" LVL 5%8"x15" 63/4"x12" (2) 13/4x9V1" LVL 3V8.,x12 5�8„x9" (3) 13/4x9%2"LVL 5%8x12" 6%"x10%2" (2) 13/gx7%4" LVL 3%8"x9" 5%8"x7%2" (3) 13/4x74" LVL 5V8"x9" 63/4"x7V1„ NOTES F. LVL BEAMS IN THE HEADER SCHEDULE MAY, AT THE CONTRACTOR'S OPTION, BE REPLACED BY GLULAMS AS INDICATED ABOVE. G. GLU-LAMS USED AS REPLACEMENTS FOR LVL BEAMS AS SPECIFIED IN THIS TABLE SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: Fb = 2000psi ALLOWABLE BENDING STRESS Fv = 175 psi ALLOWABLE SHEAR STRESS E = 1,600,000 psi ELASTIC MODULUS H. OTHER GLU-LAM SIZES ARE POSSIBLE IF APPROVED BY THE STRUCTURAL ENGINEER TYP HEADER & OPENING DETAIL SCALE NTS 394DT07 2'-0" (2) WIND STUDS EACH SIDE HEADER ARING STUDS CH SIDE F SCHEDULE TYP TRUSS BEARING DETAIL SCALE 3/4" = 1'-0" TYP TRUSS SECTION SCALE 1" 2'- 0" 5'-4" 6'-0" 1O'-0" 6' 0" 10'-0" 6' 0" 10'-0" 6' 0" 10'-0" 6'-0" 5'-4" 1 � I I r--------- I I I I I I --------- ---------- ---------- = i PRE ENGINEE WOOD TRUSS a X'-X" 0C. RIDGE LINE ED I I ' I I i I I I I I I 1 I 1 1 I I I I 1 I I I I I 1 I �1 _---_____- - i 1 1 1 I I it __J I I 1 I I I I I I -4" 6'-0" 10'-0" 6'-0" 10'-0- 6'-0 CO v 394DTXX J940TXX —LINE OF CAVE BRICK VENEER UP TO 3'-8" AFF - HORIZONTAL WOOD SIDING ABOVE 3'-8" ATE 10'-0" 6'-0" 10'-0" 6'-0" 5 -4" ROOF FRAMING PLAN G W S � � � Q ? p 4 O O n W S lJ m Z l� N W �O�OQ�O,n Z ZF�ovima -z zyy 2 a W 2 Y~ W G oo�oLLo�¢ z 5cwio��-a? WV �WV1�2 N ZGZ Z � ma Z w3<�ao��r �owww r o G z tn2 I a1mccO a �z oz` wz VOZ I OZtjGO 7F W2-ON,n� �mwE z x CJZ wow�pia �o i ��L-��•�_If GEC (VuIT CI P _ 748 WHALERS WAY' BLDG E, SUITE 200 FORT COLLINS, CO 80525 (970) 223-1820 a� o� o� 0 N � v o _ � Op rn x � v � o 4 m+ o y c � _V 0 a�w � � a y f C G O y c PRL),LECi <03c14 o „I�Tt 0=�114,'02 w DRAWN MG cz z �n n SCALE : 1/8" - 1'-0" 394p1on1 Copvrwnt 2001 K 3c A Inc 1