HomeMy WebLinkAboutPOUDRE VALLEY HEALTH SYSTEM HARMONY CAMPUS MEDICAL CENTER SECOND - Filed CS-COMMENT SHEETS - 2005-03-074v- 5I Do,. w crporaand -'ii,o 1 ..rive c Co1'.'. 1,. CO 80525 November 7, 2003 Mr. Cameron Gloss Current Planning Director City of Fort Collins 281 North College Avenue Fort Collins, CO 80521 Dear Cameron, We are pleased to submit the following Project Development Plan for the Public Improvements Infrastructure for the PVHS Harmony Campus. This PDP will serve as a framework for future project submittals within the Harmony Campus. Construction phasing for road, utility and drainage improvements will be addressed with subsequent development applications based on these overall infrastructure plans. Conceptual Review comment response In addition to the initial Conceptual Review meeting, we have held subsequent meetings with CDOT, Engineering, Utilities, and Traffic staff to review specific design issues. We also held a 'Pre -Submittal' meeting to review the items to be included with this submittal. All issues that were discussed at the Conceptual Review Team meeting have been addressed with this PDP (or will be addressed with subsequent Project Development Plans as applicable) with the following exceptions: Lighi and Power Comment 5: A utility coordination meeting will be held after the initial round of review is completed by City staff. Engineering Comment 7: The applicant/owner assumes that with this project that there will not be any specific street oversizing fees applicable as with this project there is not any specific vertical development. Applicant / Owner understands that each development project will be held accountable for the then current City of Fort Collins Oversizing Fees. Applicant / Owner also assumes that for all public street improvements provided for each development project that the City will reimburse per the':hen current City Oversizing Reimbursement Policy. Engineering Comment 2: The applicant/owner assumes for this project that there will not be any Larimer County Street Oversizing Fees as there is not any specific vertical development related to this application. Applicant / Owner understands that each development project will be held accountable for the then current Lorimer County Street Oversizing Fees. andsEape architecture I planning I urban design voice- 970.22, 7577 fax: 970-'23. 1 827 Project Comments Sheet M°'"'J Selected Departments City of Norl ('ollins Department: Engineering Date: January 5, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUTS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: January 07, 2004 Note - Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: General Number: 24 Created: 1 /5/2004 [1/5/04] No additional comments on this submital. Comments will be made with Final Compliance submital. All comments on this submital are related to FC plans. Additional comments will be provided at that time. Signature Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat _ Site Drainage Report Other Utility _ Redline Utility Landscape Page 1 City of Fort Collins Project Comments Sheet Selected Departments Department: Water Wastewater Date: January 6, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUTS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: January 07, 2004 Note - Please identify your redlines for future reference Issue Contact: Jeff Hill Topic: General Number: 25 Created: 1 /5/2004 [1/5/04] Prior to final acceptance the following information will need to be provided. -Profiles of all sewer mains and water mains larger than 12-inches. -Lengths of pipe between all fittings, thrust blocks, valves, manholes, etc. -All appropriate water and sewer details. -All information necessary for the construction of the proposed water and sewer lines. Number: 26 Created: 1/6/2004 [1/6/04] Provide a minimum of 5 feet of separation between the 12-imch water main in Snow Mesa Drive and the proposed median/curb and gutter. Number: 27 Created: 1/6/2004 [1/6/04] Label all area on the plat which are intended to be utility easements as utility easements. See plat, site, landscape and utility plans for other comments. Signature / -G-Jzi-, Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other .� Utility Redline Utility ✓ Landscape Page I Project Comments Sheet Selected Departments Department: Stormwater Utility Date: January 13, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUTS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: January 07, 2004 Note - Please identify your redlines for future reference Issue Contact: Basil Harridan Topic: Drainage Plan Number: 8 [1/13/041 Created: 12/2/2003 Still no phasing plans provided. Easements need to be provided for proposed detention pond on north side of Timberwood Drive. Easements need to be vacated for abandoned pond and drainage swalei Need to discuss who maintains drainage facilities. Effect on downstream properties, i.e. Stetson Creek detention pond should still be evaluated. [12/2/03] The drainage plan needs to show what the assumed imperviousness of all basins are in order to be able to check the proposed imperviousness in the future as the site develops. Pond numbering is very confusing from existing ponds to proposed ponds. It is not clear which portion of the pond will be built when and where as this site develops. It is suggested that a phasing plan be provided. Please provide a phasing plan for the drainage infrastructure. Maybe this site should have 2 or 3 drainage phases where the drainage infrastructure is constructed rather than doing a bit of pond enlargement with each building, that could get very confusing and could cost more in the long run. What will be done with the pond area that will be filled in ?? Please make sure area is seeded and mulched. Please provide easements for all proposed detention areas and vacate the easement for the pond area that will be filled in and no longer be used for detention. CHECK ]HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat _ Site Drainage Report Other_ Utility _ Redline Utility Landscape Page 1 Za)nProject Comments Sheet Selected Departments Cilyuf Norl toliins Department: Engineering Date: March 16, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: January 07, 2004 Mote - Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: Civil Plans Number: 34 Created: 3/16/2004 [3/16/04] CS300 - see redline plans Need to specify a typical Not approved street pavement section indicating minimum pavement depth of 6 inches from existing Timberwood Drive to Snow Mesa due to lack of cover at RCB's Number: 35 Created: 3/16/2004 [3/16/04] Lack of cover see CS 300 Number: 36 Created: 3/16/2004 [3/16/04] CS 351 Need to use Concrete Pavement design for area over RCB's on Snow Mesa from existing development to intersection with west Timberwood due to lack of cover --- Number: 37 Created: 3/16/2004 [3/16/041 Cs 500 show RCB's at ditch crossing, show concrete pavement for portion of street as discussed on sheet CS 351 Dave Stringer March 16, 2004 Signature Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat _ Site Drainage Report Other_ Utility _ Redline Utility Landscape Page 1 Number: 38 Created: 3/16/2004 (3/16/04] CS 505 see comment CS 300 Need revised soils report for all public streets. Report for PVH 3rd Filing shows expansive soils Number: 39 Created: 3/16/2004 [3/16/041 CS 557 some cross slopes either exceed or do not meet minimum/maximum cross slopes, please correct Number: 40 Created: 3/16/2004 [3/16/04] Once phasing has been agreed upon need to show phasing on all applicable sheets Topic: Plat Number: 33 Created: 3/16/2004 [3/16/041 Name of Snow Mesa wrong Change Page 2 Dave Stringer - PVH Infastructure plans From: Dave Stringer To: Cameron Gloss; jim alien-morley Date: 3/ 1 G/04 11:07AM Subject: PVH Infastructure plans Jim, attached are my comments for the PVH infastructure plans, I will give you redlines and hard copy of comments on Thursday March 18th after meeting with Tess. Dave Page 1 Page 1 Dave Stringer - PVHInfiStrucFinal.doc Project Comments Sheet Selected Departments C.ita of Fait C olluia Department: Engineering Date: Project: March 16, 2004 PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 'I All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: January 07, 2004 Note - Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: Civil Plans Number: 34 Created: 3/16/2004 [3/16/041 CS300 - see redline plans Need to specify a typical Not approved street pavement section indicating minimum pavement depth of 6 inches from existing Timberwood Drive to Snow Mesa due to lack of cover at RCB's Number: 35 Created: 3/16/2004 [3/16/04] Lack of cover see CS 300 Number: 36 Created: 3/16/2004 [3/16/04] CS 351 Need to use Concrete Pavement design for area over RCB's on Snow Mesa from existing development to intersection with west Timberwood due to lack of cover --- Number: 37 Created: 3/16/2004 [3/161041 Cs 500 show RCB's at ditch crossing, show concrete pavement for portion of street as discussed on sheet CS 351 Dave Stringer March 16, 2004 Signature Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other Utility Redline Utility Landscape Page 1 Dave Stringer - PVHInfiStrucFinal.doc Page 2 Number: 38 Created: 3/16/2004 [3/16/041 CS 505 see comment CS 300 Need revised soils report for all public streets. Report for PVH 3rd Filing shows expansive soils Number: 39 Created: 3/16/2004 [3/16/04] CS 1557 some cross slopes either exceed or do not meet minimum/maximum cross slopes, please correct Number: 40 Created: 3/16/2004 [3/16/04] Once phasing has been agreed upon need to show phasing on all applicable sheets Topic: Plat Number: 33 Created: 3/16/2004 [3/16/041 Name of Snow Mesa wrong Change Page 2 stantec-:.nm Y'. EA RS) April 14, 2004 Cameron Gloss City of Fort Collins Planning 281 N. College Fort Collins, CO 80521 RE: Poudre Valley Health System - Harmony Campus Infrastructure PDP Dear Cameron ISSUES: Department: Current Planning Issue Contact: Cameron Gloss Topic: Subdivison Number: 29 Created: 1 /9/2004 [1/9/04] Snow Mesa Drive is incorrectly noted as "Timber Trail Road" on the subdivision plat. As was discussed at the 12/16 meeting the applicant, the plat will need to be revised to reflect this change. REPEAT COMMENT. RESPONSE: Road name has been changed Department: Engineering Issue Contact: Dave Stringer Topic: Civil Plans Number: 34 Created: 3/16/2004 [3/16/041 CS300 - see redline plans Need to specify a typical Not approved street pavement section indicating minimum pavement depth of 6 inches from existing Timberwood Drive to Snow Mesa one to lack of cover at RCB's RESPONSE: We have shown concrete pavement here. Number: 35 Created: 3/16/2004 [3/16/04] Lack of cover see CS 300 April 14, 2004 Pape 2 of 5 RESPONSE: We have shown a typical section for 6 inches minimum of pavement on Timberwood W. and concrete pavement section on Snow Mesa Drive. Number: 36 Created: 3/16/2004 [3/16/04] CS 351 Need to use Concrete Pavement design for area over RCB's on Snow Mesa from existing development to intersection with west Timberwood due to lack of cover. RESPONSE: We have shown the concrete Section Number: 37 Created: 3/16/2004 [3/16/04] Cs 500 show RCB's at ditch crossing, show concrete pavement for portion of street as discussed on sheet CS 351. RESPONSE: We have shown the concrete Section Number: 38 Created: 3/16/2004 [3/16/04] CS 505 see comment CS 300 Need revised soils report for all public streets. Report for PVH 3rd Filing shows expansive soils RESPONSE: The Soils report is being completed and will be submitted in the next week Number: 39 Created: 3/16/2004 [3/16/04] CS 557 some cross slopes either exceed or do not meet minimum/maximum cross slopes, please correct. RESPONSE: These have been corrected except for Snow Mesa Drive near Harmony Road where it is in a grade transition. Here the longitudinal grade will be steep enough. Number: 40 Created: 3/16/2004 [3/16/04] Once phasing has been agreed upon need to show phasing on all applicable sheets RESPONSE: We have provided phasing sheets at the back of the set Sheets CS 700-702. Topic: Plat Number: 33 Created: 3/16/2004 [3/16/04] Name of Snow Mesa wrong. Please change. RESPONSE: This has been changed Engineering Comment 7: The applicant/owner will contact Matt Baker to discuss the financial participation requirements for the proposed traffic signal. Applicant/Owner 4V- is assuming that standard City of Fort Collins Oversizing Reimbursements for qualified projects apply to this project at the time the signalized intersection is constructed. Engineering Comment 10: A phasing plan will not be provided with this submittal. The purpose of this submittal is to provide a framework for future development projects within the campus. Future project development applications will provide phasing plans based on these infrastructure plans. At this time the sequence and timefrome for future projects has not been determined. We have included a copy of the Conceptual Review Letter with our submittal for your reference. Thank you for your assistance with this application. Please feel free to call if you have any questions or need any additional information. Sincerely, For BHA Design, Inc. Angela K. Milewski Stantec April 14, 2004 Page 3 of 5 Department: Stormwater Utility Issue Contact: Basil Hamdan Topic: Drainage Plan Number: 8 Created: 12/2/2003 [3/9/04] Swale along east property line should be placed within a drainage easement. RESPONSE: A drainage easement has been provided Please address how the drainage will affect the downstream private property, of particular concern is the effect of the additional runoff on the Stetson Creek HOA maintained detention pond. RESPONSE: Storm pipe across Snow Mesa at inlet A-3 does not have the required cover. (2 feet from road base) RESPONSE: We have called out a concrete paving section for this. Please show box culvert crossing of water line on water line profile. Call out clearances after the lowering. RESPONSE: This is now shown. Topic: Erosion Control Number: 6 [3/9/04] Created: 12/2/2003 Sediment/Erosion Control Plan Comments Poudre Valley Health Systems Harmony Campus Infrastructure Project November 24, 2003 The sediment/erosion control submittal is incomplete - no plan, no calculations, no report. Please submit a complete set of documents/calculations per City of Fort Collins requirements. Second Review February 23, 2004 April 14, 2004 Page 4 of 5 Same comment. RESPONSE: We have revised the large note on the erosion control to say that no contruction will occur with out an erosion control plan. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 25 Created: 1 /5/2004 [1/5/04] Prior to final acceptance the following information will need to be provided. -Profiles of all sewer mains and water mains larger than 12-inches. -Lengths of pipe between all fittings, thrust blocks, valves, manholes, etc. -All appropriate water and sewer details. -All information necessary for the construction of the proposed water and sewer lines. RESPONSE: These are shown Number: 26 Created: 1 /6/2004 [1/6/04] Provide a minimum of 5 feet of separation between the 12-imch water main in Snow Mesa Drive and the proposed median/curb and gutter. RESPONSE: This has been done Number: 27 Created: 1 /6/2004 [1/6/04] Label all area on the plat which are intended to be utility easements as utility easements. See plat, site, landscape and utility plans for other comments. RESPONSE: This has been done Number: 30 [3/11/04] Show and label ail valve RESPONSE: This has been done Created:3/11/2004 s Number: 31 Created: 3/11/2004 [3/11/04] Show and label concrete encasement on sewer lines which cross above or with in 18- inches vertically of water mains. The standard depth of bury for water lines with in the City of Fort Collins service area is 4.5 feet to 5.5 feet. Avoid water line lowerings which require fittings when possible. Stantac April 14, 2004 Page 5 of 5 RESPONSE: This has been done. Many of the lowerings are at the existing portion of the water line and need to be mechanically lowered. Number: 32 Created: 3/1 1/2004 [3/11/04] Provide a phasing plan for the water and sewer lines if these utilities are not to be installed all in one time period. See site, landscape and utility plans for other comments. RESPONSE: This has been done. Sincerely, Sincerely, Jim Allen -Morley Senior Project Manager Tel (970) 482-5922 Fax: (970) 482-6368 Jallen-morley@stantec.corn '541:1.Project Comments Sheet i� Selected Departments # • City of Fort C011ins ®� Department: (Engineering Date: April 26, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: April 28, 2004 (Note - Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: Civil Plans Number: 38 [4/26/04] Created: 3/16/2004 [3/16/04] CS 505 see comment CS 300 Need revised soils report for all public streets. Report for PVH 3rd Filing shows expansive soils Number: 40 [4/26/04] Created: 3/16/2004 [3/16/04] Once phasing has been agreed upon need to show phasing on all applicable sheets Topic: Utility Plan Number: 42 Created: 4/26/2004 [4/26/04] Cover Sheet - Please show elevations used as bench marks not just point reference Number: 43 Created: 4/26/2004 [4/26/04] Please label Bike lanes on Signing and Stripping plans (Typical) Signature Date CHECK: HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other_ Utility Redline Utility Landscape Page I Number: 44 Created: 4/26/2004 [4/26/04] Please show typical cross section of all public streets indicating widths, curb and gutter type and etc. Number: 45 Created: 4/26/2004 [4/26/041 CS 513 Please increase size of drawing. Lines and text are not scannable Number: 46 Created: 4/26/2004 [4/26/04] Bike lanes need to be shown correctly CS 532 Number: 47 Created: 4/26/2004 [4/26/04] Signal to be built with this project by Developer. If not typical CDOT Standard please provide a design for signal bases. Show pole locations on applicable sheets Number: 48 Created: 4/26/2004 [4/26/04] Good set of plans Page 2 Dave Stringer - PVH signal warrant Page 1 From: Ward Stanford To: Matt Delich Date: 5/6/04 4:50PM Subject: PVH signal warrant r Hi Matt, After reviewing the TIS's for the PVH site and the signal warrant, I've come across an item I need some input on. The following is my DIMS comment: [4/30/04] As best I can tell from the TIS memo and the March 30, 2004 TIS, the site will generate approx. 180 PM trips (3/30 TIS). The Timberline and Timberwood intersection increased by 105 trips (diff. of Wb ST Back and Wb ST Total), therefore 75 of the PM Snow Mesa Nb trips are from the development. The remaining 130 (195 PM NbLt's + 10 NbRt's - 75 from site) must be PM peak trips from the neighborhood connection of Timberwood. City counts for Nb Corbett are less in the PM than in the AM. Snow Mesa's Nb PM peak hour volumes are higher in the PM than AM, but not due to PVH site traffic. There must be something I'm missing or not following correctly. Please provide additional documentation and conversation regarding the expectation of 120 PM Peak hour trips from the adjacent neighborhood via Timberwood to Snow Mesa. Per our Syncro volumes for Corbett and Harmony we show about 170 vph Nb in the PM, and 480 vph Nb in the AM. And I seem to recall having seen numbers you provided possibly in the bound TIS for the site indicating about 200 vph in the PM, and roughly 400 in the AM. So I'm having some trouble with the PM exiting numbers in the "Warrant" TIS. Any assistance you could provide would be appreciated. Sincerely, Ward Stanford Traffic Systems Engineer City of Fort Collins wstanford@fcgov.com 970.221.6820 CC: Cam McNair; Dave Stringer; Eric Bracke; Mark Jackson 6a Selected Issues Report City of Fort C ollins � "rnkf.. Date: 05/24/2004 PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 1 COMMENTS DUE 5/26/04 ISSUES: Department: Engineering Issue Contact: Dave Stringer Topic: Civil Plans Number:38 Created:3/16/2004 Unresolved [4/26/041 [3/16/04] CS 505 see comment CS 300 Need revised soils report for all public streets. Report for PVH 3rd Filing shows expansive soils Number:40 Created:3/16/2004 Unresolved [4/26/041 [3/16/04] Once phasing has been agreed upon need to show phasing on all applicable sheets Topic: Covers,heet Number:65 Created:5124/2004 Pending [5/24/041 Name of cover sheet needs to match name of plat ( See redline plans) Number:66 Created:5/24/2004 Pending [5/24/04] Still need CDOT approval for Harmony Road portion of plans. Have meeting schedulked for May 26th at 1:30 PM to discuss Topic: Phasing, Plans Number:62 Created:5/24/2004 Pending [5/24/04] See comment 62 (if still applicable) as it relates to latest phasing plans for imfastructure Topic: Utility Plan Number: 47 [5/24/04] Page 1 Created:4/26/2004 Pending [4/26/041 Signal to be built with this project by Developer. If not typical CDOT Standard please provide a design for signal bases. Show pole locations on applicable sheets Topic: Utility Plans Number:63 Created:5/24/2004 Pending [5/24/04] If TIS doesn't meet signal warrants then will need some alternate design for intersection of Snow Mesa and Harmony Number: 64 Created:5/24/2004 Pending [5/24/04] 1 didn not find any detail on how landscaped median drainage (per LCUASS 7.5.1 - median drainage) was being addressed Page 2 STAFF PROJECT REVIEW (ih'nF 14 n9 Collln> BHA DESIGN Date: 05/26/2004 LUKEOLDENBURG 4803 INNOVATON DR. FT. COLLINS, CO 80525 Staff has reviewed your submittal for PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 1, and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Dave Stringer Topic: Coversheet Number: 65 Created: 5/24/2004 [5/24/04] Name of cover sheet needs to match name of plat ( See redline plans) Number: 66 Created: 5/24/2004 [5/24/04] Still need CDOT approval for Harmony Road portion of plans. Have meeting schedulked for May 26th at 1 30 PM to discuss Topic: Phasing Plans Number: 62 Created: 5/24/2004 [5/24/04] See comment 62 (if still applicable) as it relates to latest phasing plans for imfastructure Topic: Utility Plan Number: 47 [5/24/041 Created: 4/26/2004 [4/26/04] Signal to be built with this project by Developer. If not typical CDOT Standard please provide a design for signal bases. Show pole locations on applicable sheets Topic: Utility Plans Number: 63 Created: 5/24/2004 [5/24/04) If TIS doesn't meet signal warrants then will need some alternate design for intersection of Snow Mesa and Harmony Number: 64 Created: 5/24/2004 [5/24/041 1 didn not find any detail on how landscaped median drainage (per LCUASS 7. 5.1 - median drainage) was being addressed Department: Stormwater Utility Topic: Erosion Control Number: 6 [5/25/041 Fourth Review May 24, 2004 Issue Contact: Basil Harridan Created: 12/2/2003 1. Erosion Control calculations are contained in Appendix H, not Appendix G as stated in the body ofyour report. Page I 2. The notes on your sheet CS 221 need to be updated to the most current notes (available from stormwater development review). If the project is to be constructed in phases, each phase should have its own stormwater management plan which includes individual phase report, calculations, and surety. This "Master Infrastructure Plan" should not contain any stormwater management/erosion control information, except the note that each phase will have stonnwatcr management as shown in the plans for that phase. [4/27/041 Since there will be construction done off of these plans an erosion control plan and report is still expected for this project development plan. t3/9/04] Sediment/Erosion Control Plan Comments Poudre Valley Health Systems Harmony Campus Infrastructure Project November 24, 2003 The sediment/erosion control submittal is incomplete - no plan, no calculations, no report. Please submit a complete set of documents/calculations per City of Fort Collins requirements. Second Review February 23, 20041 Same comment. Department: Transportation Planning Issue Contact: Tom Reiff Topic: General Number: 50 Created: 4/27/2004 [5/25/041 Please provide an up to date phasing plan. Currently, the temporary sidewalk is shown on the Primary Care PDP, but not on the PVH infrastructure plan. Please include on both plans for clarification and label it as being constructed during the appropriate phase. [4/27/041 Where is the temporary pathway for pedestrians that is called for in the TIS from Timberwood Dr. to Snow Mesa? Will there be a sidewalk constructed with Timberwood and Snow Mesa? Is the fire access easement suppose to provide this connection? If so it needs to be ADA accessible. Please clarify with a phone call 416-2040. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number: 32 Created: 3/11 /2004 [5/26/041 [4/29/041 [3/11/04] Provide a phasing plan for the water and sewer lines if these utilities are not to be installed all in one time period. Provide all information necessary for the termination of phased water mains (temp fire hydrant for flushing). Sanitary sewer mains may only be stubbed a maximum of 2 feet or must be extended to the next manhole. Provide profiles of all proposed sanitary sewer mains. Number: 53 Page 2 Created: 4/29/2004 L7Project Comments Sheet Selected Departments Cirpot fort Collins Department: Engineering Date: December 3, 2003 Project: PVH HEALTH SYSTEM - HARMONY CAMPUTS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: December 07, 2003 Note -Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: Civil Plans Number: 9 Created: 12/3/2003 [12/3/03] Existing irrigation ditch to stay within right-of-way until future road improvements to Harmony Road are made Number: 10 Created: 12/3/2003 [12/3/03] No comments for this submittal. Project ready for hearing Number: 11 Created: 12/3/2003 [12/3/03] General Comments as it relates to Final Development Plans: Plat needs to show easements as shown on redline plans. Suggest that each tract be related at time of PDP submittal for these lots. This will allow for more defined easements when building pads sites are more defined. Southern drive off Timberwood servicing existing structure needs to be removed to accommodate the traffic that will be generated with future build out. Number: 15 Created: 12/3/2003 [12/3/03] Need irrigation owner's signature block on plat Signature Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other_ Utility _ Redline Utility Landscape Page I [5/26/041 [4/29/04] List all sanitary sewer manholes which are to be adjusted. Include the existing and proposed rim elevations. Include the manhole adjustment detail on the detail sheet. Number: 54 Created: 4/29/2004 [5/26/041 [4/29/041 Coordinate the other plan sets for this site with this plan set. Show and label all proposed stubs for MOB and Primary Care Fac. On these plans. Coordinate all sheets of this plan set with one another. Number: 56 Created: 4/29/2004 [5/26/041 [4/29/04] Clearly define all aspects of ALL the water and sewer main constructions (i.e. fittings, valves, thrust restraint, etc.). See site, landscape and utility plans for other comments. Be sure and return all of your reclined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, Cameron Gloss City Planner Page 3 Project Comments Shee'v Selected Departments � 1 it f N ..t C IIICI ' y O OI O S i Department: Engineering Date: June 13, 2004 Project: PVH HEALTH SYSTEM - HARMONY CAMPUS INFRASTRUCTURE PDP - TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: Review Date (Vote - Please identify your redlines for future reference Issue Contact: Dave Stringer Topic: Coversheet Number: 66 [6/13/04] ATMU i�: E.' if &ZAP0I1L I [5/24/04] Still need CDOT approval for Harmony Road portion of plans. Have meeting scheduled for May 26th at 1:30 PM to discuss. Additional meeting set for June 24th at 1:30 for further discussion Topic: Utility Plan Number: 47 [6/13/04] [5/24/04] Created: 4/26/2004 [4/26/041 Signal to be built with this project by Developer. If not typical CDOT Standard please provide a design for signal bases. Show pole locations on applicable sheets Signature Date CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other_ Utility Redline Utility Landscape Paae I Topic: Utility Plans Number: 69 Created: 6/13/2004 [6/13/04] CS001 add check to box as shown regarding CDOT access ramp details Number: 70 Created: 6/13/2004 [6/13/041 Cs512 add note referencing Landscape plan for type of sprinkler system to be used in medians without inlets Number: 71 Created: 6/13/2004 [6/13/041 Cs 200 move road detail to right edge of page Number: 72 Created: 6/13/2004 [6/13/04] Cs000 note variance for radii at Snow Mesa and Harmony Road, Cs 003 Cdot access ramp standards add note Number: 73 Created: 6/13/2004 [6/13/04] Cs 513 add detail regarding existing concrete test section and how asphalt will abut to it Number: 74 Created: 6/13/2004 [6/13/041 Cs 532 Revise note regarding signal to meet current status Number: 75 Created: 6/13/2004 [6/13/04] Cs 602 CDOT access ramps provide M&S standard details Number: 76 Created: 6/13/2004 [6/13/04] If no other CDOT concerns after June 24 meeting , Engineering is ready for mylar Page 2 F City of Fort Collins Current Planning FINAL PLAN REVISIONS COMMENT SHEET DATE: June 9, 2004 TO: Engineering PROJECT: #32-98D PVHS, Harmony Campus, Infrastructure PDP - Final Plan Revisions All comments must be received by Cameron Gloss no later than the staff review meeting: June 23, 2004 Note - Please identify your redlines for future reference (c:GH(-- GLOSS. r o /,VpY Name (please print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat Site Drainage Report _Other _Utility Redline Utility _Landscape o Ito Q VaN WO Project Comments Sheet Selected Departments 'itv of For[ Collins Department: Transportation Planning Is -A' , Date: December 3, 2003 Project: PVH HEALTH SYSTEM - HARMONY CAMPUTS INFRASTRUCTURE PDP -TYPE 1 All comments must be received by Cameron Gloss in Current Planning, no later than the staff review meeting: December 07, 2003 Note - Please identify your redlines for future reference Issue Contact: Tom Reiff Topic: Civil Plans Number: 16 Created: 12/3/2003 [12/3/03] The intersection design at Snow Mesa and Harmony Rd. will need to include directional ramps for the future ped crossing of Harmony (see red lines). Number: 17 Created: 12/3/2003 [12/3/03] The bike lane width when it is located between the right turn lane and the through lane only needs to be 6' in width, not 8' as shown. Number: 18 Created: 12/3/2003 [12/3/03] Add additional crosswalks at the Snow Mesa intersections with Timberwood and the driveway just south of the Harmony intersection (see red lines). Also please straighten some of the crosswalks to cross the street more directly. Number: 19 Created: 12/3/2003 [12/3/03] Reconfigure the right turn lane as it approaches the Harmony intersection and the first driveway. Please see red lines for the new design. Signature ate CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS Plat Site Drainage Report Other_ Y Utility _ Redline Utility Landscape Page I RESPONSE TO CITY OF FORT COLLINS COMMENTS: 12 22 2003 BY: Sear Brown and bha design ISSUES: Department: Current Planning Issue Contact: Cameron Gloss Topic: Landscape Plan Number: 7 Created: 12/2/2003 A maximum of 15% of any one -tree species is permitted within the development. It appears that one species- Washington Hawthorn- exceeds this limitation. Staff acknowledges that two varieties are provided, but they appear to be the same species and therefore don't comply with the minimum species diversity. Please add an additional tree species. Response: The quantities shown on the plan are incorrect. The plant schedule is representational at this time and quantities for individual species have not been calculated. The actual plant species for each plant will be indicated on the plans in final design. The re -submittal of this PDP will not indicate any quantities in the plant schedule. Topic: Subdivison Number: 5 Created: 12/2/2003 Please remove "Preliminary" from the Subdivision Plat title. Administrative action on the subdivision request will be for a final version of the plat. Response: This will be addressed with the final plat as well as all of the other specific commentns. Department: Engineering Topic: Civil Plans Issue Contact: Dave Stringer Number: 9 Created: 12/3/zuu,3 [12/3/03] Existing irrigation ditch to stay within right-of-way until future road improvements to Harmony Road are made Response: Comment noted. Number: 10 Created: 12/3/2003 [12/3/03] No comments for this submittal. Project ready for hearing Response: Comment noted. Number: 11 Created: 12/3/2003 [12/3/03] General Comments as it relates to Final Development Plans: Plat needs to show easements as shown on redline plans. Suggest that each tract be replatted at time of PDP submittal for these lots. This will allow for more defined easements when building pads sites are more defined. Response: The plat shows easements necessary for utilities that will be extended from under the road to outside of the right of way. Southern drive off Timberwood servicing existing structure needs to be removed to accommodate the traffic that will be generated with future build out. Response: The roadway will be designed without this opening. It has also been noted on the plat. Number: 15 Created: 12/3/2003 [12/3/031 Need irrigation owner's signature block on plat Response: The signature block has been included. Department: Light & Power Issue Contact: Alan Rutz Topic: General Number: 1 Created: 11/25/2003 Underground electric lines (UGE) are drawn incorrectly on the Overall Utility Plan, Contact Light and Power for maps of the existing underground electric system. Response: We will come to the electric offices prior to final design to get the correct locations. Number: 2 Created: 11/25/2003 Please provide potential future building and parking lot layouts along Timberwood and Snow Mesa to help facilitate electric system design. Response: We have provided a concept of this to you at the Utility Coordination Meeting ( I think) If not we can get a concept plan to you. Number: 3 Created: 11/25/2003 Streetlights will be placed along public streets. A 40 feet separation on both sides of the light is required between canopy trees and streetlights. A 15' separation on both sides of the light is required between ornamental trees and streetlights. See note 14 on Landscape Plan. Response: The plan will comply with the required landscape spacing from the streetlights. Lighting design will be completed by the city of Fort Collins Light and Power Department during final design. The landscape plan will be adjust when the lighting design is completed. Department: Stormwater Utility Issue Contact: Basil Hamdan Topic: Drainage Plan Number: 8 Created: 12/2/2003 [12/2/03] The drainage plan needs to show what the assumed imperviousness of all basins are in order to be able to check the proposed imperviousness in the future as the site develops. Response: All of the new development is considered to be 80% impervious. Please refer to the erosion control plans for Coefficient values. Pond numbering is very confusing from existing ponds to proposed ponds. It is not clear which, portion of the pond will be built when and where as this site develops. It is suggested that a phasing plan be provided. Response: You are right it is confusing. The SWMM model from Anderson Engineering has 500 type numbering and the original SWMM modeling has 300 type numbering. Before Final design Sear Brown will discuss with you the preferred numbering system. What will be done with the pond area that will be filled in ?? Please make sure area is seeded and mulched. Civil Response: This set of plans does not address the filling in of the pond because there will be no construction until another development is proposed. When a development is proposed that will cause the pond to be filled in then we will call for seeding and mulching. Planners Response: The site will be vegetated or reconfigured with subsequent development. Please see note 21. On sheet 1 of the landscape plan. Please provide easements for all proposed detention areas and vacate the easement for the pond area that will be filled in and no longer be used for detention. Response: This will be done in response to the needs of each development proposal. As discussed we have noted that the pond will be built in no more than three phases. Topic: Erosion Control Number: 6 Created: 12/2/2003 [12/2/031 Sediment/Erosion Control Plan Comments Poudre Valley Health Systems Harmony Campus Infrastructure Project November 24, 2003 The sediment/erosion control submittal is incomplete - no plan, no calculations, no report. Please submit a complete set of documents/calculations per City of Fort Collins requirements. Response: This will be addressed with final construction Plans. Department: Transportation Planning Issue Contact: Tom Reiff Topic: Civil Plans Number: 16 Created: 12/3/2003 [12/3/03] The intersection design at Snow Mesa and Harmony Rd. will need to include directional ramps for the future ped crossing of Harmony (see red lines). Response: This; has been included. Number: 17 Created: 12/3/2003 [12/3/031 The bike lane width when it is located between the right turn lane and the through lane only needs to be 6' in width, not 8' as shown. Response: Comment noted Number: 18 Created: 12/3/2003 [12/3/03] Add additional crosswalks at the Snow Mesa intersections with Timberwood and the driveway just south of the Harmony intersection (see red lines). Also please straighten some of the crosswalks to cross the street more directly. Response: This has been done: Number: 19 Created: 12/3/2003 [12/3/03] Reconfigure the right turn lane as it approaches the Harmony intersection and the first driveway. Please see red lines for the new design. Response: As discussed previously there is a lot of storage required. This configuration maximizes the storage. We are keeping the same configuration. Department: Water Wastewater Issue Contact: Jeff Hill Topic: Civil Plans Number: 12 Created: 12/3/2003 [12/3/03] The intersection of Snow Mesa and the private drive on the north side of this development needs to be realigned with the existing 12-inch water main. Response: We are moving the 12" water line per our utility coordination meeting. Number: 13 Created: 12/3/2003 [12/3/03] Several water and sewer services are proposed throughout this site. Provide an overall development plan which justifies the locations of these proposed services or perhaps it would be better to extend services from the mains when the exact location of the future buildings is better known. If services are extended now and they are located in the wrong location for future buildings they will need to be removed from the mains and new services extended which could double the cost of the future services. Response: We have adjusted the services per out utility coordination meeting Number: 14 Created: 12/3/2003 [12/3/03] A meeting is needed between the developer, developers consultants and the City utility staff to facilitate this project. See the master infrastructure plan for other comments. Response: The meeting has been held and issues resolved. When resubmitting plans, please return all of your redlined plan sets. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Cameron Gloss CuTent Planning Director