HomeMy WebLinkAboutCOURTYARDS AT MIRAMONT PUD - Filed CS-COMMENT SHEETS - 2003-07-31Communi° Planning and Environmental S, -ices
Planning Department
City of Fort Collins
March 28, 1994
Mr. Frank Vaught
1113 Stoney Hill Drive
Fort Collins, CO 80525
Dear Frank:.
Staff has completed its interdepartmental review for Courtyards at
Miramont P.U.D., Preliminary and Final (two lots) and offers the
following comments:
1. On the final plat...for..the two.lots:
A. Please label the "Point of Beginning" on the map.
B. The map and the legal description do not close.
C. A note should be provided stating the purpose of the
interior dashed lines.
D. The lot should be noted as Lot One.
2. For the Final, the phasing of the utility construction should
be clarified. Also, plans for the Final Utility Plan set
should be separate from the Preliminary Utility Plan set.
Although a simultaneous submittal is being reviewed for the
April P & Z, the two plan sets should be separated.
3. The Soils; Report is satisfactory for the Preliminary but is
too outdated for the Final (1980). A new Soils Report is
required for the Final P.U.D.
4. For both the Preliminary and Final, U.S. West advises that
telephone facilities generally occupy rear lot utility
easements,. The developer is responsible for provision of all
trench, street crossings, ditch crossings for telephone
facilities within the project, and the developer pays up front
construction costs for facilities within the development. Any
relocation of existing telephone facilities required by these
plans will be paid for by the developer.
5. Light and Power advises that private drives are not charged
for nor provided with for streetlighting. The developer is
encouraged to use high pressure sodium light sources in order
to be compatible with surrounding public street lighting.
6. For both the Preliminary and Final, Public Service Company
advises if electric and gas are both to run behind the
--
sidewalk,, then it appears that the street trees will conflict
with the gas line. The gas line will be four feet behind the
electric line. Street trees must be at least four feet from
the gas line.
7. Columbine Cable Television --is interested .in obtaining an
easement from Boardwalk to the area south of the irrigation
pond along the emergency access.
8. Comments from the City's Stormwater Utility will be provided
to the consulting engineer under separate cover. Also,
redlined Utility Plans will be forwarded to the consulting
engineer„
9. For both the Preliminary and Final, the Plans Examiner for the
Building Inspection Division advises that the exterior walls
of the single family homes located closer than three feet from
the property lines must be one -hour, fire -resistive
construction with no openings. Also, parapets extending 30
inches above the roof surface are required unless the
exceptions as outlined in Section 1710, U.B.C., are met.
Projections.(eaves, overhangs, cornices, etc.) may not extend
over property lines. Projections must comply with Sections
1711 and 504 U.B.C.
10. The Parks and Recreation Department cautions that the curb cut
for emergency access is located on a parcel that is under
negotiation for acquisition for a neighborhood park. This
curb cut is subject to review by Parks and Rec in the event
that the park site is purchased.
11. All dwelling units must be within 400 feet of a fire hydrant.
12. Staff has worked closely with the developers of Oak Hill
Apartments to.. -coordinate bicycle/pedestrian paths that link
the Tennis and Fitness Center, the Apartments, the Courtyards,
and the potential neighborhood park. A north -south segment of
this network should be added to The Courtyards P.U.D. just
east of Building Envelope #10 to connect with the proposed
path in Oak Hill Apartments.
13. Tract Q of the Oak -Cottonwood Farm is designated as "Business
Services and/or Multi -Family Residential." The proposed
P.U.D. issfor single family. Therefore, an amendment to Tract
Q of the O.D.P. should accompany the Preliminary and Final
requests. The amendment request should include an analysis of
the multi -family parcels remaining in the O.D.P.
14. It is suggested that the land use data be revised. It appears
that Phase VI, like Phase VII, is not part of the Preliminary
P.U.D. Therefore, these 2.2 acres should be subtracted from
the gross acreage resulting in a new gross of 11.11 acres, as
referenced in the Planning Objectives. The new gross density
would then be 4.14 dwelling units per acre, not 3.5 d.u./ac.
15. Is fencing proposed for the rear yards that face the pond? If
so, the P.U.D. should provide a schematic. Will such a fence
feature gates for access to the path? Please describe rear
yard treatment for those units along the pond.
This concludes Staff comments.at-this time. In order to stay on
schedule for the April 25, 1994 Planning and Zoning Board meeting,
please note the following deadlines:
Plan revisions are due April 6, 1994.
P.M.T.'s, 10 prints, renderings are due April 18, 1994.
If you have any questions or concerns regarding these comments,
please feel free to call our office to discuss or to set up a
meeting to explore the issues in depth.
Sincerely:
�V
Ted Shepard
Senior Planner.
xc: Kerrie Ashbeck, Civil Engineer
0
June 10, 1994 VS H E A R
ENGINEERING
Project No: 1410-01-94 CORPURATIUN
Roger Buffington
City of Fort Collins Water and Sewer
700 Wood Street
Ft. Collins, Colorado 80521
Re: Courtyards at Miramont, First Filing; Ft. Collins, Colorado
Dear Roger,
This is a response to your review comments concerning Courtyards at Miramont, First Filing
which were presented with the returned mylars on yellow tabs. These yellow tabs are being
returned with the mylars, hopefully in the location originally placed, for your subsequent review.
SHEET 2 - MASTER IMPROVEMENTS PLAN
The 8" water main stub will be abandoned at Boardwalk Drive south of Lots 1 and 2 (item 7
of the MASTER IMPROVEMENTS PLAN CONSTRUCTION NOTES). Item 7 has been
revised to direct abandoning the water line stub at the main.
Item 6 of the MASTER IMPROVEMENTS PLAN CONSTRUCTION NOTES has been
modified to expand on abandoning the sewer main at the inanhole.
Item 12 of the MASTER IMPROVEMENTS PLAN CONSTRUCTION NOTES has been
modified to indicate a swivel tee.
SHEET 3 -SANITARY SEWER PLAN AND PROFILE
* We have added the sewer service to the third lot on the north side of the private drive
according to the station presented in the sewer and water service suinmary to the right of the
plan view. This will also correspond to the service location shown on Sheet 2. May we enter
a manhole with a sewer service?
* We have added subdrain cleanouts according to the subdrain detail provided on the detail
sheet. Only one cleanout will be constructed with this Filing at ME A-2. This is where
sewer line construction ends for this filing.
* Sewer service stationing is provided in summary form to the right of the plan view.
* Water line deflection data has been added to the drawing (see profile) based on
manufacturer's deflection specifications.
SHEET 5 - DETAIL SHEET
* The City's sewer bedding detail has been added.
* The water line lowering detail has been removed.
4836 S. College, Suite 12 Fort Collins, CO 80525 (303)226-5334
PAGE 2
June 10, 1994
Project No: 1410-01-94
Re: Courtyards at N iramont, First Filing; Ft. Collins, Colorado
If you have further questions ar comments, please call at 226-5334.
Brian W. Shear,
Shear Engineering Corporation
BWS J jj
attachments
cc: Albrecht Homes
Kerrie Ashbeck:, City of Fort Collins Planning
Dave Simpson; Connell Resources