Loading...
HomeMy WebLinkAboutCOURTYARDS AT MIRAMONT PUD SECOND - Filed CS-COMMENT SHEETS - 2003-07-31Commu y Planning and Environmental vices Planning Department City of Fort Collins May 23, 1994 Bill Albrecht Albrecht Homes 4836 South College Avenue Fort Collins, CO. 80525 Dear Bill, Staff has reviewed your documents for the Courtyards at Kiramont P.U.D., Second Filing - Final that were submitted to the City on May 2, 1994, and would like to offer the following comments: 1. Public Service Company of Colorado has stated that they need 13 feet from back of sidewalk for a utility easement, with no trees in, the easement if electric and gas mains are both to be behind the walk. 2. A copy of the comments received from Sharon Getz of the Building Inspection Department is attached to this letter. 3. U.S. West has stated that their comments and concerns are the same as for the Courtyards at Miramont P.U.D., Second Filing, Preliminary Plan. 4. The Light i Power Department has indicated that they will have to install the electric system to accommodate more than just the 2 lots shown in Phase I. Their facilities would have to be installed for a minimum of 10 lots. Please contact Janet Perry if you have questions about electric service to the site. Janet can be reached at 221-6700. 5. A copy of the comments received from the Natural Resources Department is attached to this letter. 6. The comments received from the Engineering Department are as follows;; a. The 1980 soils report submitted is out of date, but it is OK since you will not be constructing public streets in this development. Also, the report does not pertain to the exact area of this development. b. You must construct sidewalk along Boardwalk Drive adjacent to the detention "irrigation" pond (Tract B). 281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6730 MEMORANDUM TO: Dennis Greenwalt, AT& T Broadband ✓Bob Rulli, Qwest ✓Jim Dewilde, Xcel Energy .,,Glen Schluter, Stormwater /Roger Buffington., City Water and Wastewater ;-Doug Martine, Light and Power FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2, 2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Miramont PUD, Second Filing, located at 5000 Boardwalk #23 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage easement is proposed for vacation, as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center by April 14, 2004. If we do not hear from you by this date, we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank you. No Problems Problems/Concerns as follows: ';Map Output Page 1 of I Easement vacation DroDosal on Lot 23 of Courtvards at Mirannnnt I Legend P week Railroads Sir"t Centerlines P. Evers. Sl ream and ,A/ Ditches ■ Lakes and Bodies of Wafer City Units LOT Z% I (2.tVATYAVVb AT M%qArAwJT* �p UID I %jEr bglD Flutj(q http://gisims.fcgov.comlservleticom.esri.esrimap.Esrimap?ServiceName=overview&Client... 4/1/2004 •„� • ,7-4 1 1 -Ij — — — 06IRG COP'Aa I; PRIVATE DRIVE { I I I , . a a• EXISTING BUILDING lnlulpllunu� � , 1 •• 1 I ! -4 I 1 '• 1 1 -. 1-1 J T --�-- I.- { � I I I I I I • • { i ( { { Maw a - GAFAM f i 1 p I � I g I i I � � CRMV PACE 1 I = I Il 23 c ' `• N _• M BND HACIENDA �GgSs� Uiil. � i ar.► M.M. 1•.W 614w(r l I �=Ck M VAWAM NO NUR FAm w SITE PLAN FOR LOT 21 COURTYARDS AT MIRAMONT P.U.D., SECOND FILING FORT COLLINS. COLORADO OWNER: ALBRECHT HOMES M MEMORANDUM TO: Roger Buffington., City Water and Wastewater FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2, 2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Miramont PUD, Second Filing, located at 5000 Boardwalk #23 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage easement is proposed for vacation, as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center by April 14, 2004. If we do not hear from you by this date, we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank you. X! o Problems Problems/Concerns as follows: MEMORANDUM TO: Dennis Greenwalt, AT& T Broadband FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2.2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Nliramont PUD, Second Filing, located at 3000 Boardwalk ;4^_3 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage casement is proposed for vacation. as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center be April 14. 2004. If we do not hear from you by this date. we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank yoL No Problems XProblems/Concerns as follows: Comcast Cable would like to the utility lines located and set up an on site meeting to make sure our facilities would not be impacted by this request. I can be reached at 484-7166 to set up a meeting after locates have been scheduled. [Mak (e7[7:1a111u1 TO: Jim Dewilde, Xcel Energy FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2, 2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Miramont PUD, Second Filing, located at 5000 Boardwalk #23 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage easement is proposed for vacation, as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center by April 14, 2004. If we do not hear from you by this date, we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank you. X No Problems Problems/Concerns as follows: .u� City of Fort Collins MEMORANDUM TO: Glen Schluter, Stormwater FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2, 2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Miramont PUD, Second Filing, located at 5000 Boardwalk 423 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage easement is proposed for vacation, as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center by April 14, 2004. If we do not hear from you by this date, we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank you. 4r No Problemsh/dlp��/—%-��{ �Gy VPfir`�"� Problems/Concerns as follows: MEMORANDUM TO: Doug Martine, Light and Power FROM: Sheri Wamhoff, Development Review Engineer DATE: April 2, 2004 RE: REQUEST TO VACATE A PORTION OF AN EASEMENT Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Miramont PUD, Second Filing, located at 5000 Boardwalk #23 which is north and east of Boardwalk Drive. A portion of the 8 foot side lot access, utility and drainage easement is proposed for vacation, as shown on the attached drawing. There is currently a deck that extends into the easement here and the owner of the property desires to build a pergola above the deck. Please sign and return any comments to Sheri L. Wamhoff in the Development Review Center by April 14, 2004. If we do not hear from you by this date, we will assume you have no objections to the proposed vacation. Please call Sheri at 221-6750 if you have any questions. Thank you. XNo Problems�'� Problems/Concerns as follows: I somlow E A/-FD2004 __ NWIN'iORANDI `\i TO: Bob Rulli, Owest FROM: Shcri Wamlintf, Development Review Frigincer DA 1 F: April ', 2001 f0 VA PCIR H'i OF AN PA�FNIIA[ F Attached for your review and comment is a sketch showing Lot 23 of Courtyards at Nliramont PUD, Second Filing, located at 5000 Boardwalk ;1�23 urhich is north and cast of Boardwalk I)rk,, . A portion oftlit,,8 foot side lot access, utility and drainage easement is proposed for vacation, as �Itowv on the attached drawing. Time is currently a deck that extends into the easement here and the owner of die property desires to build a par,,oia above the deck. Please sign and return amy comments to Sheri L. ykramlloff in the Development Review Caner by April 14, 2004. It w,e d.r not hear from you b this date, we will assm ue you have no objections to the proposed vacation. Please call Sheri at 2'? 1-07 0 i f you have, any questions. Thank you. �JNo problems Problems/Concerns as follows: uQS F R N�CO— 6� J L)TJL�` r 1'20h C. Off -site easements are needed for water and sanitary sewer across the "parks" outparcel. d. Additional comments have been sent to your engineer on red -lined utility plans. Please contact Kerrie Ashbeck if you have questions about the Engineering comments. Kerrie can be reached at 221-6750. 7. what are the "open space" connections intended to be used for? These occur between Lots 29 & 30 and 37 & 38. The subdivision plat graphically shows them but does not define them. 8. The proposed emergency access location, and type of surface, must be clearly defined. How will this occur if the "park" to the sough were to disappear? 9. The pedestrian paths in Tract A and around the irrigation pond should be 6' wide instead of the 41, as shown. Also, a path should hie provided through Tract A, to the park, between Lots 33 & 34. 10. The Land Use Breakdown on the Site Plan indicates a total of 44 lots in this filing, yet 46 lots are shown on the plan. Phase I, Lots 1 & 2, should be labeled as not being a part of the Second Filing? Also, the net density as indicated would reflect 46 dwelling units on 10.63 acres. 11. General Note 6 on the Site Plan references fencing guidelines. Guidelines are a good idea and the City would like to review these guidelines. 12. A pipe to the detention pond must be designed to include incoming flows from the tennis center to the north. The hydrology calculations will have to be revised. 13. Vehicular access between the Courtyards at Miramont, Second Filing and the Cottages at Miramont must be provided with this request., Right-of-way will have to be dedicated and should occur in the area of Lots 19 & 20. 14. Is it possible to provide landscaping along the edge of the irrigation pond, between the top of slope and the pedestrian path? This completes the review comments at this time. Additional comments may be forthcoming as the various departments and reviewing agencies continue to review this request. Please be aware of the following dates and deadlines to assure your ability to stay on schedule for the June 27, 1994 Planning and Zoning Board hearing: ****************************************************************** Plan revisions are due no later than June 9, 1994. Please contact me for the number of folded revisions required for each document. PMT's, renderings, and 8 folded copies of final revisions (for the Planning and Zoning Board packets) are due by 3:00 p.m. on June 20, 1994. ****************************************************************** Please contact me at 221-6750 if you have questions or concerns related to these comments. I would like to schedule a.meeting with you as soon as possible, if necessary, to discuss these comments. Sin erely, Steve Olt Project Planner xc: Ron Phillips Kerrie Ashbeck Advance Planning Stormwater Utility Transportation Parks & Recreation Vaught -]Frye Architects file/Project Planner July 18, 1994 Project No: 1410-01 94 Roger Buffington City of Fort Collins Water and Sewer 700 Wood Street Ft. Collins, Colorado 80521 Re: Courtyards at Miramont P.U.D., Second Filing; Ft. Collins, Colorado Dear Roger, This is a response to your review comments concerning the final utility plans for Courtyards at Miramont P.U.D., Second Filing. Please note that a second sewer line plan and profile sheet has been added to the set. The northernmost sewer line (Sewer Line A) has been extended to the east to service Lot 28. The southernmost sewer line (Sewer Line B) has been shortened. SHEET 2 - MASTER UTILITY PLAN * The 42" RCP storm sewer and the 8" PVC sewer line which are noted as existing, are being constructed with Courtyards at Miramont, First Filing. Construction for these utilities start this week. These utilities are not existing at this time, but will be completed by the time these plans are approved. We have left the "existing on the plans, but have added a note indicating that these utilities are being installed with Courtyards at Miramont, First Filing. * The 8" water main stub south of Lots 1 and abandoned at the main in Boardwalk Drive have added a note indicating that the stub is First Filing construction. 2, Courtyards at Miramont, First Filing, will be with Courtyards at Miramont, First Filing. We being abandoned with Courtyards at Miramont, * We have revised the sewer line plan and profile to extend the northernmost sewer line to Lot 28. * We have eliminated the water line to the north between Lots 10 and 19. * We have re -worked the water services to lots 24 and 28 as requested. * We have redefined the services to lots 33 and 41 so that they are perpendicular to the mains. * There will be construction phasing. The first phase of construction will be for the Courtyards at Miramont P.U.D., First Filing. Phase 2 construction will include infrastructure to service up to Lot 28. I am providing a redlined Master Utility Plan indicating construction phasing as currently planned, by Albrecht Homes. Sheet 3 of this set actually depicts the limits of Phase 2 construction and Sheet 4 of this set actually depicts the limits of Phase 3 construction. SHEET 3 - SANITARY SEWER PLAN AND PROFILE (Previously Sheet 3) SHEET 4 - SANTIARY SEWER PLAN AND PROFILE (Previously Sheet 3) The easement for that portion of the water and sewer main construction between Boardwalk Drive and the Courtyards at Miramont P.U.D., Second Filing, has been dedicated by separate instrument by Oak Farm Inc. The easement is 30' wide and is delineated on the plat of the Courtyards at Miramont P.U.D., Second Filing. 4836 S. College, Suite 12 Fort Collins, CO 80525 (303)226-5334 PAGE 2 July 18, 1994 Project No: 1410-01-94 Re: Courtyards at Miramont, Second Filing * We have re -worked the water services to lots 24 and 28 as requested. * We have prepared a sewer service summary. Please refer to Sheet 2; Master Utility Plan. * We have redefined the services to lots 33 and 41 so that they are perpendicular to the mains. * We have prepared a sewer service summary. Please refer to Sheet 2; Master Utility Plan. * Water line deflection data has been added to the drawing (see profile) based on manufacturer's deflection specifications. A general note concerning manufacturers maximum joint deflection recommendations has also been added. * The water line lowering profile nearest to Boardwalk Drive has been shortened. SHEET 5 - DETENTION POND OUTFALL STORM SEWER PLAN AND PROFILE Previously Sheet 4 * We can not obtain more separation between the sanitary sewer and the storm sewer. The sanitary sewer is defined by the existing sewer line in Boardwalk Drive and the storm sewer detention pond outfall is defined by the pond high water designated in the Miramont Master Drainage plan. Are there additional specifications or requirements you may have concerning this crossing? We, have encased both utilities because of the lack of separation. SHEET 8 - MISCELLANEOUS DESIGN PLAN AND PROFILES Previously Sheet 7 * We have revised the title block * We have eliminated the water line to the north between Lots 10 and 19. * We have encased the storm sewer 10' each side of the waterline as directed. SHEET 11 - DETAUL SHEET (previously Sheet 10) * Under drains have been noted on the plan and profiles to support the under drain / sewer line installation details. If you have ftirther questions or/comments, please call at 226-5334. Sincere Brian W. Shear, Shear Engineering Corporation BW S / jj cc: Albrecht Homes August 10, 1994 Project No: 1410-01-94 Basil Hatmdan City of Fort Collins Storm Water Utility P.O. Box 580 Ft. Collins, Colorado 80522 Re: Courtyards at Miramont P.U.D., Second Filing; Ft. Collins, Colorado Dear Basil, This letter is written in response to your review comments for the Courtyards at Miramont P.U.D., Second Filing, which were dated May 2, 1994. Each item is addressed according to the number of the comment. All detention pond data is represented according to the Amended Overall Drainage Plan (ODP) which was prepared by RBD, Inc. This data was closely coordinated with RBD, Inc. A 1.0' freeboard is provided with a top of pond elevation of 70.4. Any required revisions to the detention pond summary have been made. The summary is located on the Drainage and Erosion Control Plan. 2. Detention pond 340 at the corner of Lemay and Boardwalk, is part of the Miramont Overall Drainage Plan. The amended ODP addresses Pond 340 for the contributing flows, including those from detention pond 313. Our understanding is that the pipe from pond 313 to pond 340 must be constructed prior to construction of the residences within the limits of Courtyards at Miramont P.U.D., Second Filing. We anticipate construction of the pond release pipe with Courtyards at Miramont P.U.D., Second Filing. The pipe will be constructed to the Lemay Avenue swale as shown on the detention pond release storm sewer plan and profile. The outlet structure at pond 340 for the pipe system under Lemay will be designed and constructed with the next phase of Miramont Development. 3. All onsite drainage improvements facilitating the Oak Hill Apartments P.U.D., the Cottages at Miramont P.U.D and the Miramont Tennis Center, will be provided with Courtyards at Miramont P.U.D., Second Filing construction. This includes the following: * The storm sewer along Boardwalk Drive to the north boundary of Courtyards at Miramont P.U.D., Second Filing (south boundary of Oak Hill Apartments). * The storm sewer in the Courtyards at Miramont P.U.D., Second Filing open space or greenbelt area to the north boundary of Courtyards at Miramont P.U.D., Second Filing (south boundary of Oak Hill Apartments). The remainder of this storm sewer, which goes through the Oak Hill Apartments P.U.D. site, will be constructed with Oak Hill Apartments P.U.D. * The drainage Swale through the east portion of the Courtyards at Miramont P.U.D., Second Filing open space or greenbelt area to the north boundary of Courtyards at Miramont P.U.D., Second Filing (Cottages at Miramont P.U.D.). 4836 S. College, Suite 12 Fort Collins, CO 80525 (303)226-5334 PAGE 2 August 12, 1994 Project No: 1410-01-94 Re: Courtyards at N iramont P.U.D., Second Filing; Ft. Collins, Colorado 4. The flows to detention pond 313 to Concentration point B, do include contributing runoff from a portion of the Cottages at Miramont P.U.D. site. Drainage basin delineation has been clarified to represent contributing areas. We have incorporated the Overall Miramont Drainage Plan, which includes the Cottages at Miramont P.U.D. site, as part of the final drainage and erosion control report. Channel designs and cross sections will be provided for the overland flows through the open space or greenbelt areas. There are two (2) swales which have be designed. Details of both channel sections still need to be added to the drainage plan. 5. Proposed grading matches both the Oak Hill Apartment P.U.D. and the Collinwood sites. We had detailed the Master Grading Plan to indicate the proposed Oak Hill Apartments P.U.D. grading design, as well as the Collinwood existing grades. We have now updated the Drainage and Erosion Control Plan to do the same. We are incorporating the Final Grading Plan into the report as well. 6. The rear yards of the lots adjacent to Collinwood (Basin L) will drain due east to the Collinwood detention pond, then ultimately to detention pond 340 at the intersection of Boardwalk and Lemay. Because Collinwood will not be fully developed according to the final drainage plan for Collinwood, there is capacity available for this small contribution. An analysis of the actual impervious areas contributing to the Collinwood detention pond was performed. We have determined that the composite 'C' factor for the existing conditions at the site are significantly less than those calculated by RBD, Inc. as part of the Grading and Drainage Plan for Oakridge West P.U.D., First Filing. The comparison is as follows: * 0.49 for current conditions for 100 year storm * 0.70 by 1ZBD for original design conditions for the 100 year storm The smaller runoff coefficient can be attributed to the fact that the Collinwood site has not been fully developed in accordance with the original site plan. Several buildings and additional parking areas that are shown on the approved plans for Oakridge West P.U.D., First Filing have not been built as of this time. It is our understanding from Collinwood representatives, that not all improvements noted on the original plan will be constructed. The rear yards of the southernmost lots will drain undetained to the south, then be conveyed to the east within the same 20' drainage easement which is provided for the detention pond outfall storm sewer. The drainage plan will be revised to clarify the channelization of these flows. 7. Street capacity calculations for the private drive, have been added to the final Drainage and Erosion Control report. Street capacity graphic illustrations will be included on the Drainage and Erosion Control Plan. 8. A legal description for the offsite 20' easement for conveying flows to detention pond 340 has been prepared and presented to Oak Farm, Inc. for review and dedication. PAGE 3 August 12, 1994 Project No: 1410-01-94 Re: Courtyards at Miramont P.U.D., Second Filing; Ft. Collins, Colorado 9. Drainage contributions from the Cottages at Miramont have been included with this report. However, final onsite Cottages at Miramont P.U.D. design has not yet been started and will not be a part of this report. You have required that a project specific drainage report for the Cottages at Miramont P.U.D. be prepared with the Cottages final design. Contributions from the Cottages at Miramont P.U.D. to the pond are addressed with the contributing areas for sub -basin lb (Refer to page 4 in the calculations). 10. Additional comments made on the Utility Plans and the report have been addressed as well. We acknowledge that approval of the Amended Oak/Cottonwood Farm Overall Drainage Study will have to precede approval of this plan. We understand from conversations with staff at RBD, Inc., that the revisions to the Amended Oak/Cottonwood Farm Overall Drainage Study has not yet been re -submitted, but will be re -submitted early next week. We have also addressed a majority of the comments noted on the redlined Utility Plans and those comments noted in the Final Drainage and Erosion Control Report. These comments are addressed as follows: 1. A Final Grading Plan is currently being prepared to show the actual final grading that will occur with residence construction. This final grading will be consistent with the Drainage Plan basin delineation. The Final Grading Plan will be incorporated into the final Drainage and Erosion Control Report to replace the Overlot Grading Plan (OGP). The OGP reflects the grading required to complete construction up through the road and curb and gutter stage. 2. Please note that the open space or greenbelt areas are already dedicated as access, utility and drainage easements. Refer to the revised final plat which is also being re -submitted for your review. We will add a note to the GRADING AND DRAINAGE GENERAL NOTES on the Drainage and Erosion Control Plan to that effect. Please note that this is a general note: on the Cover Sheet of the Utility Plans as well. The open space or greenbelt areas facilitate the storm sewer for the Tennis Center and the drainage channel for the Cottages at :Miramont P.U.D. 3. The drainage summary table has been revised and re -applied to the Drainage and Erosion Control Plan in a more readable condition. 4. Design flow and pipe capacity data is shown the outfall plan and profile. This information has not been added to the Drainage and Erosion Control Plan. This data will be added to the Drainage and Erosion Control Plan. 5. No detail has been provided for the detention pond outfall storm sewer at the pond. The outfall is simply a open ended flared end section at the detention pond with an invert elevation set at 66.0 6. The date of the referenced Amended Oak/Cottonwood Farm Overall Drainage Study has been revised to April 20, 1994. PAGE 4 August 12, 1994 Project No: 1410-01-94 Re: Courtyards at N iramont P.U.D., Second Filing; Ft. Collins, Colorado 7. The Final Drainage and Erosion Control Report Drainage Facility Design section has been expanded to discuss contributing flows from the Cottages at Miramont P.U.D. in more detail. If you have further comments or questions, please call at 226-5334. Sincerely, i ., Brian W. Shear, l'.Fsr Shear Engineering; Corporation BWS / jj attachments cc: Albrecht Homes Kerrie Ashbeck; City of Fort Collins Planning RBD, Inc. Water, Waste and Land