HomeMy WebLinkAboutASAMERA PUD - Filed CS-COMMENT SHEETS - 2003-07-31ITEM:
COMMENT S*
("EED < eEll
y o � ►
0 IF D w PrT r�-� r,
AA LD <- off--f TIT
.,�)) o0i (
CITY OF FORT COLLINS P.O. BOX 580, FORT COLLINS, COLORADO 80522 PH (303) 484-4220
PLANNING DIVISION EXT. 655
May 20, 1982
Ms. Donna Lockwood
Architecture Plus
318 E. Oak
Fort Collins, CO 80524
Dear Donna:
The staff has reviewed the application for preliminary approval of the Asamura
PUD and would offer the following comments:
I. The entrances to the project should be designed as curb cuts rather than
curb returns.
2. Per applicant's request for certain variances from the street standards of
the City, the staff would make the following recommendations:
a. Variance request to reduce the required setback of curb cut along
Mason Street to 150-feet is acceptable.
b. Variance request to reduce the required setback of curb cut along
Horsetooth Road to 75-feet is not acceptable. The applicant should
work with staff to relocate the curb cut as far west as possible.
C. Variance request to the requirement of a 50-foot separation from any
parking space to the flowline of an adjacent street is acceptable.
However, the site plan should clearly indicate treatment of parking
spaces as Employee Parking Only.
3. The larger pump island would appear to conflict with interior traffic cir-
culation and should be re-evaluated. Is adequate stacking space being
provided?
4. The water service for this property will be tapped to an 8-inch water line
in South Mason Street which belongs to the Fort Collins -Loveland Water
District. The applicant will pay City fees and charges and be considered a
City customer. Arrangements for the tap will be made with the District.
5. The following repays apply to this property:
#42: Sewer line in Mason Street $896.15
#41:. Sewer line in Horsetooth Road $507.67
#79-3: Water line in Horsetooth Road - approximately $14.25 per front
foot along Horsetooth Road based upon May 1982 inflation adjustor
Ms. Donna Lockwood
Architecture Plus
May 20, 1982
Page 2
6. Building envelopes should be dimensioned on all sides and distance to two
property lines indicated.
7. The loading zone must be at least 500-sf in area with no dimension less
than 50-feet.
8. Bicycle and motorcycle parking spaces should be indicated.
9. A 6-foot easement on north property line.and an 8-foot easement along Mason
Street and Forsetooth Road will be required for utility purposes. Please
indicate on site plan. Voltage available to this property will be 120/208
30 4W.
10. Sidewalks along Mason Street and Horsetooth Road should be indicated on the
site plan.
11. Security lighting should be indicated on the site plan.
12. Applicant should provide evidence as to how gas spills on the site will be
handled.
13. How does the project reduce energy use (Criteria #29)? Please explain.
14. Additional landscape treatment interior to the site and along property
lines will be required for screening, visual and shading purposes.
15. Applicant should investigate special pavement treatment at curb cuts to
enhance pedestrian use.
16. Location of trash areas and screening thereof should be indicated.
17. The staff questions the points you have taken on Point Chart D and would
recommend we meet as soon as possible to discuss this item.
18. For what purpose was 10-foot easement along north property line originally
dedicated? Please explain.
I would recommend we meet as soon as possible to discuss the above items. Re-
visions to the plans should be delivered to this office no later than Friday,
June 4, 1982. Also, on Monday, June 21, 1982, 8-12"xll" reductions and colored
renderings of all plans should be submitted. If you should have any questions,
please feel free to call.
Sincerely yours,
Joe Frank
Senior Planner
cc: Rick Ensdorff, Traffic Engineer
Mauri Rupel, Development Engineer
Ken Waido, Chief Planner
I
. UA I L:
0
L 7.�
"I-- pl—k ko 1 1141 t— M --F
W,
A cx�
�.� ram, � � �
S;fC_ 4„
Ivew
N 0 ssf �
^4 116we�
rilu %4-1#1 A, t — — I - —, \-/
Si 40)&j -2
1, L lict'
64 A'A C
CITY OF Fu;; i (11)LLIN, P.O. r_' X 580, FORT COLLINS, COLORADO 805..:. PH (303) 484-4220
DEVELOPMENT CENTER EXT.655
September 23, 1982
Mr. Dana Lockwood
Architecture Plus
318 East Oak
Fort Collins, CO 80524
Dear Dana:
The staff has reviewed the application for final plan approval of the Asamera
Oil PUD and would offer the following comments:
1. The applicant should contact a City Crime Prevention Officer to discuss
security measures.
2. If the applicant anticipates any excavation in or near Horsetooth Road,
the Western Slope Gas Company Division Office in Campion, Colorado
(667-3404) must be contacted so the actual line location can be deter-
mined before construction begins.
3. The access easement along western property line should be identified on
the subdivision plat.
4. The basis for the bearings should be indicated on the plat.
5. The subdivision plat should show two public survey monuments.
6. The cap numbers on the corner monuments should be shown.
7. The owners" signature hox on the plat should be changed to include
"President" and "Attest: Secretary."
8. The "Director of Engineering Services" should be "City Engineer" on
the plat.
9. The plat should be called "Subdivision Plat of the ."
10. The existing 10-foot utility easement along the north property line needs
to be vacated. This item will go to the City Council as a separate item
from the PUD plan.
11. A handicapped ramp will be required at the Mason/Horsetooth corner.
Mr. Dana Lockwood
Architecture Plus
September 23, 1982
Page 2
12. Site plan should show relocated fire hydrant.
13. The site plan should show sidewalk transition from 7-foot where it abuts
the curb to 5-foot as it leaves the curb.
14. Size of wager and sewer services should be shown on the site plan.
15. If the street asphalt is less than 2-years old where a cut is planned,
a 20-foot wide patch will be required.
16. The utility plans should show a storm drain running from the parking lot
through an inlet, then pipe into a storm sewer in Horsetooth Road.
17. Building envelope and footprint and dimensions thereof should be indicated.
18. Length of parking spaces should be indicated.
19. Height and material of fence for trash area should be indicated.
20. Walls of buildings where located less than 10-feet from a property line
must be fire resistive. Overhangs are not permitted closer than 3'4" to
property lines according to the Building Codes.
21. Energy saving features to the plan and building should be indicated on
the site plan.
22. Each of the interior landscaped areas near the pumps should be at least
80-sf in ground area to allow for root aeration and should have raised
concrete curbs. Also, ground cover for these areas should be indicated.
Please revise.
23. Applicant should justify substituting "privet hedge" for lilacs along
west property line.
24. A note should be added that architectural renderings of the building
are on file with the City.
25. The staff would recommend that the minimum plant sizes be used as indicated
on the attached plant list.
26. The signed mylars of the subdivision plat and site plan should be delivered
to this office no later than Monday, October 18, 1982.
27. The signed "Landscape and Open Space ovenants" should be submitted on
Monday, October 18, 1982.
28. The mylar of the landscape plan and building elevations should be submitted
on Monday, October 18, 1982.
I would recommend we meet as soon as possible to discuss the above items. On
Wednesday, October 6, 1982 revisions to the plans should be submitted. Also,
Mr. Dana Lockwood
Architecture Plus
September 23, 1982
Page 3
on Monday, October 18, 1982, 8-1/2"xll" reductions of all plans and colored
renderings of the site plan should be submitted. If you should have any
questions, please feel free to call.
Sincerely yours,
Joe Frank, AICP
City Planner
JF/fsr
cc: Mauri Rupel, Development Center Director