Loading...
HomeMy WebLinkAboutCLARENDON HILLS THIRD - Filed CS-COMMENT SHEETS - 2003-07-07r 7 Sep 88 Vr :— i —,i � i Y d i i �•� 9 ITF m- 35-86F CLARENDON HILLS, 3rd Filing - PRELIMINARY SUBDIVISION No Problems Problems or Concerns (see 1)c10w) Date Signature DATE: 6 Deaa DEPARTMENT: t,�7 Yg►vee"-rin 7 Sep 88 35-86F CLARENDON HILLS, 3rd Filing PRELIMINARY SUBDIVISION No Problems Problems) or Concerns (see below) I I . Date Signature 4 /NSA _, f A T- . 7 Sep 88 _ 1 ITEM_ 35-86F CLARENMN HILLS, 3rd Filing - PRELIMINARY SUBDIVISION Date No Problems Problems or Concern(see rS belo ri) Sol L, S (7RA WAGE i To 5 U8N 1 7Q�. Signature Z buaq DA 7 Sep 88 ITEM. 35-86F CLARENDON HILLS, 3rd Filing - PRELIMINARY SUBDIVISION No Problems Problems or Concerns (see below) i J 6?--'V 7 5; v,5M J -T6 00 _ Date ��ls met Signature Develc ient Services Planning Department Citv of Fort Collins September 20, 1988 Mr. Rob Persichitte Intcrmill Land Surveying, Inc. 1301 North Cleveland Loveland, CO 80537 Dear Mr. Persichitte: Staff has reviewed the Clarendon Hills Third Filing Preliminary Subdivision Plat, #35-86F, and has the following comments: 1. The Project Engineer will receive additional comments red lined on the plat and utility drawings. 2. The north end of Hinsdale Drive must be provided with a turnaround. A temporary cul de sac is sufficient. 3. Coordinate casement locations with water and sewer, light and power and other utilities. Water and sewer service will be provided by Fort Col- lins/Loveland Water District and South Fort Collins Sanitation District respectively. 4. Provide a location map on the plat. 5. Show lot area. on each lot. Lots with less than forty feet street frontage must have at least two off-street parking spaces. 6. Submit a preliminary drainage report. 7. The proposed grading doesn't represent realistic final grading. Back lot drainage could be a problem. Please address this issue by providing more detailed grading and designate drainage paths within specified drainage casements. 8. The existing contours show several drainage paths through the site. Are off -site flows being cut off by this development? If so, off -site flows must be routed around or through the site. 300 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750 Clarendon Comments Page 2 9. Vcrify the capacity of the existing detention pond. 10. All cul de sacs and "bubbles" need to neck down to a 36 foot pavement width adjacent to the street. H. Verify that the proposed development is consistent with the previously submitted traffic study. 12. Indicate how the developer proposes to landscape and maintain "Tract A". 13. Submit an updated APO list. This concludes Staff comments at this time. Please note the following dates and let me know if there are any problems in meeting the deadlines: Plan reilsions are due October 5, 1988 PNIT's, colored renderings, and 10 prints are due October 17, 1988 Final mylars and documents are due October 20. 1988 As always, please, call if there are any questions or concerns. Sincerely, Linda Ripley Project Planner LR/bh cc: Joe Frank, Assistant Planning Director Mike Herzig, Development Coordinator Develk neat Service` %'lann.rib ;1epartiiietit Citv or Fort CoilinS 17 1988 Mr. Rob Pcrsichitte lntcrmill Land Surveying, Inc. 1301 North Cleveland I.ovcland, CO 80537 Dear Mr. Persichitte: Staff has reviewed the Clarendon Hills Third Filing Final Subdivision Plat, _,_-86G, and has the following comments: I I'hc Project Engineer will receive additional comments red lined on the plat and utility drawings. Pro% idc a 80 foot wide temporary turn -around at the north end of Hinsdale Drive. l'hanac Larimcr County Voc-Tech Center to read Front Range Community Coilccc Larimcr Count��� Center. i. Provide a note on the plat indicating who will be responsible for the landscape maintenance of Tracts A - G. 5. Attach a copy of the grading plan to the drainage report. 6. All agreements with off -site property owners regarding drainage across their property must be obtained prior to final approval by the City. 7. Off -site drainage casements are required in the First Filing. Please refer to the utility plans for specific locations. 8. The drainage report must include calculations for the pipe and swale that is draining sub -basins 11, 13 & 14. Provide calculations for the sidewalk culvert. 9. There are concerns regarding the street capacity during a major storm event. Plcasc see the: specific comments in the report. 10. A variance must be requested for the proposed depth of water in cul-de-sac „F _)00 LaPorte Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-h750 Page 2 11. See additional comments in the report regarding design assumptions and calculations. 12. The grading plan does not meet our criteria. See specific comments on the plan. 13. A general note must be added to the utility plans regarding the mainte- nance of all storm drainage facilities located outside the right of way. The City will not be responsible for maintenance. 14. The irrigation ditch diversion plan must be approved by the ditch owner. 15. Minimum finish floor for lots ad lac-.nt to the drainagc swales and inlets must be specified. 16. Erosion control measures have not been clearly addressed. ! 7. Rcmovc the signature block for City Council. IS. The plat needs a certification by a licensed attorney that the statement of land ownership on the plat is correct. 19. Include the date of preparation on the plat. This concludes Staff comments at this time. Please note the following dates and Ict nic know if there are any problems in meeting the deadlines: Plan revisions are due January 4, 1989 PNIT's, colored renderings, and 10 prints are due January 17, 1989 Final mylars and documents are due January 19, 1989 As always, please call if there are any questions or concerns. Sincerely, 7! l Linda Ripley Project Planner LR/bh cc: Joe Frank, Assistant Planning Director Mike Herzig, Development Coordinator J _ 5 Citv of Fort Collins TO: Dex .)pincnt Semites Plannin,, Departnient GARY HUETT PUBLIC SERVICE MEMORANDU,N FROM: Mike Herzig, Development Uoordinator i E: 6,, 1988 RE: Subdivision Utility Plans Submitted for your review and comment are utility plans for: Please respond by: Clarendon Hills ire Filing December 16, 1.988 '()o pro W CMA3 ax-e AMA� , 300 LaPorte Avcnue • P.O. Box 5,S0 • Port Collins, CO 50522-0580 • (303) 221-6750