HomeMy WebLinkAbout140 W MULBERRY ST - SPECIAL INSPECTIONS - 3/15/2014MAX Field Construction Office 3000 South College Ave., Suite 201 Fort Collins, CO 80526 fcgov.com/maxconstruction Delivery by hand March 15, 2014 City of Fort Collins 1 +0 Building Services 281 North College Avenue Fort Collins, CO 80524 I Subject: MAX BRT — Building Permit No. B1300301— Mulberry northbound station Bus Stop and Station Specialty Inspections To whom it may concern: The MAX BRT stations and stops are nearing final completion. As such, this letter shall serve as a i. general compliance letter to certify the project was constructed in conformance with the approved plans and specifications and applicable building code. This work includes: 1. Utility installation including electrical, irrigation and communications 2. Subgrade preparation 3. Light pole footing/foundation installation 4. Concrete flatwork paving 5. Structural framing; structural steel, roofing, cladding and connections 6. Surface restoration including architectural concrete paver installation 7. Site amenity installation Personnel from the City of Fort Collins Engineering Department and Ditesco have jointly inspected; the construction work. Deficiencies identified during construction have been corrected and accepted. ,Record drawing information has been documented and will be transferred to final drawings for City of Fort Collins Engineering Departmental use. If you require any further information or supporting documentation, please contact me at 970-988-8605 or keith.meyer .ditescoservices.com. Sincer KeMeye , PV. S b'49 �ryO -76 A 6+Fi.� Cc: Erika Keeton, PE — Cii bf Fort Collins Engineering Department Ryan Dickinson — Concrete Express, Inc. file Page 1 of 1 0 Magnetic Particle Examination CTL I THOMPSO1.N p® of Welds Report � ., CLIENT: _ . JOB NUMBER: PROJECT: tA.cL9oV !',)A CT. Gn�s��r % DATE: LOCATION (' "P*OA WELD LOCATION AND IDENTIFICATION SKETCH Weld identification _ Material thickness �4 1-0 `y-V Weld joint AW5 _. Welding process 61G��✓ Quality requlrements - section no. Remarks.— ' I _ Interpretation Repairs Date Weld Ideliiification Area Accept Reject Accept Reject Remarks I • - t4 r V� J r 6 The above welds were prepared and tested in accordance with the requirements of the American Welding Society AWS D1.1 {_zg.,47 ) Structural Welding Code. AJlanufacturer or contractor 4�,AL fJ{el d of Inspection: �. _ Qry ' ' Wet J Residual Continuous ❑ AC I- DC Half -wave FIELD COPY TO TECHNICIAN _.. _ LEVEL WELD / BOLT INSPECTION REPORT SUMMARY Client Dame; CH2M HILL, INC. Inspection Date: 04/22/2013 Project: MAX BUS RAPID TRANSIT Project Number: FC05942.000 Report Number: 4 TYPE OF INSPECTION / APPLICABLE CODE O Visual Weld AWS 131.1-02 Table 6.1 ❑ Magnetic Particle Weld AWS 131.1-02 Sect. 6.10 ❑ Liquid Dye Penetrant Weld AWS 131.1-02 Sect. 6.10 Location and Description of Work: WELDS Field Rep: ALLEN BARTON ❑ Ultrasonic Weld ❑ Decking AWS D1.1-02 Sect. 6.13 AWS 131.3-02 Sect. 4.5 ❑ High Strength Bolt AISC Spec. for Structural Joints Using ASTM A 325 or A490 Bolts, Sect. 8 & 9. ❑ Anchor Bolts Project Specifications We performed a -visual inspection of the welded connections for the shop -fabricated assembly Icon A60 at CDI's shop in Denver.. We also performed a magnetic particle inspection on 10% of the A60 assembly. Please refer to the attached Magnetic Particle Examination of Welds Report for details. Plans were prepared by SSS, project no. 1552, dated 3/14113. BOLTS At the time of our inspection, the items observed met the quality standards sited above unless noted below. ❑ Discrepancies were observed, please see the attached Outstanding Discrepancies list. Specific information is presented on the following inspection reports. 351 Linden Street I Suite 1401 Fort Collins, CO 805241 Phone: 970-206-94551 Fax: 970-206-9441 Magnetic Particle Examination cTL I THOMPSON of Welds Report CLIENT: JOB NUMBER: l�G-C1Z��� PROJECT: /_W _ZrfX `A. �d/��Iyr_ DATE: y� u - LOCATION: WELD LOCATION AND IDENTIFICATION SKETCH Weld IdentificationZO!✓ Material thickness MOMAWA Weld joint AWS. Welding process Forr"A Quality requirements -section no. Remarks _ ®a■ I0 Remarks The above welds were prepared and tested in accordance with the requirements of the American Welding Society AWS 131.1, ( LO/ B ) Structural': Welding Code. Manufacturer or contractor 75D od of Inspection: ry ❑ Wet Z) Residual Continuous O AC C' OC I'7 Half -wave FIELD COPY TO _,. _ TECHNICIAN %� I���/rB LEVEL .. 77� _ dilesco BUILDING INSPECTION RECORD Mulberry NB Station Owner: City of Fort Collins — Engineering Department Contact: Erika Keeton Project Name: Mason Corridor — MAX BRT Project Number: 7332 Local Building Official: City of Fort Collins Building Permit No: B1300301 Architect/Engineer: Michael Baker Type of Construction: ll-B Contractors: General: Concrete Express, Inc. Occupancy Classifications: U-Occupancy Electrical: Sturgeon Electric Total Bldg Area: 162 ft2 Mechanical: N/A Plumbing: N/A Building General Date I Inspector ❑x Footings/Foundations . Comments: Completed under separate inspection record. 5/3/13 JB/CTL ❑ Concrete Slab / Under -Floor. Comments: N/A N/A N/A • ❑x Light Gauge Framing: Comments: Steel Studs 5/9/13 JB x❑ Sheathing Comments: Plywood Sheathing 5/9/13 . JB ❑ Fire -Resistant Penetrations Comments: N/A N/A N/A ❑ Mechanical/Energy Efficiency ... Comments: N/A N/A N/A ❑x Roofing Comments: Sheet Metal Roof 3/12/14 JB Other :. Comments: N/A N/A N/A ❑ Final Comments: Building complete and fully accepted. N/A N/A Special Date Inspector ❑ Bolt/Weld Inspection Comments: Visual weld inspection. Bolt inspection completed under separate inspection record. 5/10/13 . CTL ❑ Special Structural Concrete. Comments: N/A i N/A N/A ❑ Masonry.......• Comments: N/A N/A N/A ❑ Wood Comments: N/A N/A N/A ❑ Soils/Foundations . Comments: Building excavation completed in in -situ materials and inspected prior to installation 4/26/13 JB ❑ Spray -Applied Fireproofing Comments• N/A N/A N/A ❑ Control Systems . Page 1 of 2 Comments: N/A N/A N/A ❑ Other Comments: Electrical Date Inspector ❑ Underground . Comments: Completed under separate inspection record by City of Fort Collins. N/A N/A ❑ .Rough Walls.. Comments: Completed under separate inspection record by City of Fort Collins. N/A N/A ❑ Rough Ceilings...... Comments: Completed under separate inspection record by City of Fort Collins. N/A N/A Final ........ Comments: Completed under separate inspection record by City of Fort Collins. N/A N/A Plumbing I Date Inspector ❑ Underground ... . Comments: N/A N/A N/A ❑ Gas Comments: N/A N/A N/A ❑ Interior Water ....: . Comments: N/A N/A N/A '..Interior DWV Comments: N/A N/A N/A ❑ Final ' .:..:;;:..:... Comments: N/A N/A N/A Fire Suppression and Alarm Inspection by local.jurisdiction N/A N/A Elevator by local jurisdiction or special consultant N/A N/A Note: See attached photographs for further installation record. See daily reports for detailed account of construction progress. I MG_1607 I MG_1608 IMG_1943 IMG_2575 IMG_2577 00f�flrri 3` 7 Fl y 7 �? 76 (S" Ir0 AG1G7Gi 7�G6;�R yw Architect/Engineer Certification The stamp affixed hereto certifies installation of the marked items in general conformance with the approved project technical specifications and drawings. Page 2 of 2 CH2M HILL, INC. 9191 S. JAMAICA STREET ENGLEWOOD CO 80112 LETTER OF TRANSMITTAL Date: WEDNESDAY, APRIL 24, 2013 Project: MAX BUS RAPID TRANSIT Project No: FC05942.000 WE ARE TRANSMITTING: Weld and/or Bolt Inspection Results COPIES MAILED TO: 0 L/C CTL T on, Inc o cr•;' .� 3 3 WYN REGI 351 Linden Street I Suite 140 1 Fort Collins, CO 80524 I Phone: 970-206-94551 Fax: 970-206-9441 fti."i'1V'C'O�Ft�P+O'iRxA Ti-E+D'.,: xs CH2M HILL, INC. 9191 S. JAMAICA STREET ENGLEWOOD CO 80112 Date: 0710112013 Report ID: K92718 - FC05942.000 Report of Concrete Compressive Strength Tests Project: MAX BUS RAPID TRANSIT Supplier: MARTIN MARIETTA MASON ST FROM SOUTH OF HARMONY RD TO CHERRY MATERIALS Location: Caissons for the northbound Mulberry Street Station. Cast Date: 51312013 Ticket: 49015542 Batch Time: 11:13 Concrete Mix: CD4715 In -Lab Date: 5/4/2013 Truck Number: 088 Test Time: 12:00 Specimens Made By: JUSTIN Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Lab 68 ° F 72 OF Fog Room Physical Properties of Concrete (ASTM C143, C231, C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4500 psi @ 28 days 3.50 in. 6.4% 143.2 pcf. 73 deg. F Compressive Strengths (ASTM C39) Specimen Age in Diameter Area Max. Load Compressive Percent Type of Number Days (inches) (sq. inches) (Ibs.) Strength (psi) of fc Fracture 1 7 .4.00 12.57 62,320 4960 Average: 4960 110 2 28 4.00 12.57 73,820 5870 .3 28 4.00 12.57 69,140 5500 4. 28 4.00 12.57 70,210 5590 Average: 5650 126 5 56 4.00 CTL.lThom WYATT 04LIT REGIONAL M) 12.57 86,410 6880 Average: 6886 Comments: 4.50 yards on truck no water added on site. cc: MARTIN MARIETTA MATERIALS 351 Linden Street I Suite 140 1 Fort Collins, CO 80524 1 Phone: 970-206-9455 1 Fax: 970-206-9441 LETTER OF TRANSMITTAL CH2M HILL, INC. Gate: TUESDAY, MAY 14, 2013 9191 S. JAMAICA STREET ENGLEWOOD CO 80112 Project: MAX BUS RAPID TRANSIT WE ARE TRANSMITTING: FOR DATES: COPIES MAILED TO: Project No: FC05942.000 Weld and/or Bolt Inspection Results 5/10/201 3 351 Linden Street 1 Suite 1401 Fort Collins. CO 80524 i Phone: 970-206-94551 Far : 970-206-9441 WELD / BOLT INSPECTION REPORT SUMMARY Client Name: CH2M HILL, INC. Inspection Date: 05/10/2013 Project: MAX BUS RAPID TRANSIT Project Number: FC05942.000 Report Number: 5 TYPE OF INSPECTION / APPLICABLE CODE ❑ Visual Weld AWS D1.1-02 Table 6.1 ❑ Magnetic Particle. Weld AWS D1.1-02 Sect. 6.10 Field Rep: JACK PAPPERT ❑ Ultrasonic Weld ❑ Decking AWS D1.1-02 Sect. 6.13 AWS 131.3-02 Sect. 4.5 L7 High Strength '8olt AISC Spec: for Structural Joints Using ASTM A 325 or A490 Bolts, Sect. a & 9. ❑ Liquid Dye Penetrant Weld ❑ Anchor Bolts:' AWS D1.1-02 Sect. 6.10 Project Specifications Location and Description, of Work: Plans were prepared by Baker, project "FC 7073", dated 11/10/12. BOLTS We inspected the bolted connections of the column cap plates to the overhead beams for the following 5 stations: northbound Mulberry Street, southbound Mulberry Street, northbound Laurel'Street,'northbound Drake Road, and northbound Troutman Parkway. All of the bolts were in the snug -tight condition or greater with washers installed at the time of our inspection with the following 2 exceptions: we observed a 1/4-inch gap between the beam and the column cap plate at the west end of the top of the southeast column at the northbound Drake;Road station and a missing washer for the southeast bolt at the top of the column connection at the southeast corner of the northbound Troutman Parkway station. We also inspected the 3/4-inch diameter anchor bolts for the column base plates at the same five stations. All of the anchor bolts were in the snug -tight condition or greater with washers installed at the time of our incnartinn At the time of our inspection, the items observed met the quality standards sited above unless noted below. 2 Discrepancies were observed Specific information is presented on the following inspection reports. 351 linden Street I Suite 140 1 Fort Collins, CO 805241 Phone: 970-206-94551 Fax: 970-206-9441 LETTER OF TRANSMITTAL CH2M HILL, INC. Date: FRIDAY, JUNE 7, 2013 9191 S. JAMAICA STREET ENGLEWOOD CO 80112 project: MAX BUS RAPID TRANSIT � I Project No: FC05942.000 WE ARE TRANSMITTING: Weld and/or Bolt Inspection Results FOR DATES: 5/17/2013 REMARKS: See attached summary reports for information. COPIES MAILED TO: Linden Street I Suite 140 1 Fort Collins, CO 80524 1 rRhGre. ye 0-2K55 1 Fax' G: Q-=w-9441 WELD/ BOLT INSPECTION REPORT SUMMARY Client Name: CH2M HILL, INC. Inspection Date: 05/17/2013 Project: MAX BUS RAPID TRANSIT Project Number: FC05942.000 Report Number: g TYPE OF INSPECTION / APPLICABLE CODE O Visual Weld AWS D1,1-02 Table 6.1 ❑ Magnetic Particle Weld AWS 131.1-02 Sect. 6.10 ' Field Rep: ALLEN BARTON ❑ Ultrasonic Weld ❑ Decking AWS D1.1-02 Sect. 6.13 AWS 131.3-02 Sect. 4.5 ❑ High Strength Bolt AISC Spec. for Structural Joints Using ASTM A 325 or A490 Bolts, Sect. 8 & 9. ❑ Liquid Dye Penetrant Weld ❑ Anchor Bolts AWS 101.1-02 Sect. 6.10 Project Specifications Location and Description of Work: WELDS We, performed a visual inspection, of the welded connections for the shop -fabricated assembly A60BF at CDI's shop in Denver. We also performed a. magnetic particle inspection on 10% of the A60 assembly. Please refer to the attached Magpetic Particle Examination of Welds Report for details. Plans were prepared by Skylark Shelters, project no. 1552. i BOLTS At the time of our inspection, the items observed met the quality standards sited above unless noted below. ❑ Discrepancies were observed, please see the attached Outstanding Discrepancies list. Specific information is presented on the following inspection reports. 351 Linden St,eet I Suite 140 1 Fort Collins, CO 805241 Phone: 970-206-94551 Fax: 970-206-9441