Loading...
HomeMy WebLinkAbout323 PARKER ST - CORRESPONDENCE - 2/18/1998CITY OF FORT CO( LJNS DEVELOPMENT SERVICES - BUILDING PERMITS & INSPECTIONS February 18, 1988 To Whom it flay Concern: On February 18, 1988, at approximately 9:15 a.m. I inspected two (2) warm morning heaters located at 323 Parker Street in the City of Fort Collins. The first heater in the lower level, which could be a family or living room, was okay with one exception. The thimble into the chimney was loose and should be fastened so it will not pull away and let gases out into the room. The pipe is a single wall, black 3" pipe and is at least 6" from the wall. The second heater, located on the upper or main level, is in the utility room , being used to keep water pipes from freezing. It appears to be a 3" pipe, possibly wrapped with what I think could be asbestos. This is not acceptable and should be removed. Also, the single wall pipe is too close to combustibles with no thimble at the ceiling line. Replacing this pipe to double wall would make this unit legal. Sincerely, Jack Grove Building Inspector JG/avb �Ys w �S�s,.tt �- r � [a .'.l `.:c px: 1.��"i�. ss :�.. `s;',4�?"s a%c. _`7.3f i5-•:. �-�c ax+�`.`.�`S.. ,:--w;. :4;s ..s:.:+'� 300 LaPorte Ave. • P.O. Box 580 • Fort Collins, Colorado 80522 • (303) 221-6760