Loading...
HomeMy WebLinkAboutHUMAN BEAN AT SPRING CREEK - FDP - 37-06/A - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTAPPENDIX • SITE HYDROLOGY • WATER QUALITY POND • OPEN CHANNELS • PIPES • EROSION CONTROL EFFECTIVENESS CALCULATIONS • REFERENCE MATERIAL EROSION AND SEDMENTATION CONTROL Temporary erosion control during site construction will be provided by straw bale barriers, a sediment trap to be located within the water quality pond, vehicle tracking control at the access to College Ave., and a silt fence as depicted in the attached Erosion Control Plan. Performance Standards for the property and Effectiveness calculations for the proposed erosion control measures are included in the Appendix. Any disturbed soil to remain bare for more than 30 days will be seeded with a temporary seed mix of either warm season or cool season grass, depending on the month of the year. Two acceptable alternative seed types for this temporary vegetation are: Seedine Season Jan -Feb Do not seed Mar — May 15 Annual ryegrass, drilled at 20 lbs seed per acre May 16 — July Hybrid sudan grass, drilled at 15 lbs seed per acre Aug — Sep Annual ryegrass, drilled at 20 lbs seed per acre Oct — Dec Do not seed The contractor will be required to install and maintain all erosion control features on the site and replace any damaged elements during the construction period. Permanent erosion control will be achieved via the water quality pond. Landscaped areas will either be seeded with a permanent grass seed mix or covered with turf sod. The property owner will be responsible for maintaining all the permanent drainage and landscape features of the site. Page 8 111512007 DRAINAGE PLAN/HYDRAULIC REPORT The drainage plan for the proposed project is attached as a full-size drawing in the map pocket. The plan includes construction of curb cuts to convey site and off -site runoff to the proposed water quality pond, and HDPE pipes to convey storm water runoff from the pond to the Spring Creek channel. Each type of hydraulic structure to be installed for site drainage is discussed below. WATER QUALITY DETENTION Water quality will be provided for the Human Bean site through an Extended Detention Basin (EDB), a recognized Best Management Practice in the Urban Storm Drainage Criteria Manual Volume 3. The volume of the pond was determined based on 40-hour drain time and an 80 percent imperviousness for the site. The pond will treat a runoff depth of 0.33" over the 0.37- acre project. Calculations for pond size and outlet structure design are included in the Appendix, and outlet structure details are depicted in the Utility Plans. Storm water runoff will enter the pond via a curb cut and riprap rundown. The riprap rundown will be grounted due to the slope of the pond's sides, and will be comprised of Type VL (d5o = 6 inches) angular riprap. OPEN CHANNELS Two curb cuts will be installed to allow storm water runoff to be conveyed through the site, one at each design point listed above. The curb cuts were designed using Mannings' equation, assuming normal flow conditions, with a conservative n-value of 0.020. Both curb cuts were assumed to have a 1.0 % longitudinal slope though the cut. A spreadsheet presenting these calculations is attached in the Appendix. PH'ES Two high density polyethylene (HDPE) pipes will be installed to convey storm water runoff from the water quality pond to Spring Creek. The pipes will have capacity to convey the 100- year developed discharge from both the Human Bean and the Vision Eyeland properties (Basins A and OS-1, respectively). The pipes were sized under non -pressure flow (as open channels) using the UD-Culvert spreadsheets created by the Urban Drainage and Flood Control District. These spreadsheets are attached in the Appendix, and the results are summarized in the table below. Pipe ID Location Size, Circular Design Pipe Capacity, HDPE Discharge, cfs cfs Pipe-1 Conveys flow from the pond east 18" 6.1 7.5 to MHl, slope = 0.6% Pipe-2 Conveys flow from MH1 to 18" 6.1 21.1 Spring Creek, slope = 6% Page 7 211512007 I RUNOFF Methodolgy. Runoff at the project was evaluated for the 2-year, 5-year, 10-year and 100-year storm events using the rational method. The rational method relates discharge to the product of three terms: a runoff coefficient appropriate for site conditions and the design storm, rainfall intensity at the time of concentration, and basin area. Topography at the site was based on. 1-foot contour intervals generated from site survey. Specific guidance provided by the City's Storm Drainage Design Criteria and Construction Standards was followed in the estimation of the time of concentration. Intensity was determined from the equations summarized above. Runoff Coefficients. Runoff coefficients for application in the rational method were determined for the site using tables provided in the City of Fort Collins Storm Drainage Design Criteria and Construction Standards (May 1984, rev. April 1999). These coefficients are a function of the soil type and corresponding hydrologic soil group for the site and the percent of site imperviousness due to the expected presence of parking and drive areas, sidewalks, and rooftops. Runoff coefficients for frequent storms used for this analysis for landscaped areas, roofs, and paved areas were 0.25, 0.95, and 0.95, respectively. The proposed site will be 80 percent impervious; the remaining 20 percent will be landscaped. Composite runoff calculations were performed for the project site to determine the percent imperviousness for each basin, as depicted in the Appendix. The table below summarizes the developed runoff coefficients for the site for the 2-year, 5-year, 10-year, and 100-year storms. Oita Rnnnff f neffirienta % Impervious 2-year 5- ear 10- ear 0-year Site, weighted 80 1 0.81 10.81 0.81 1.00 Off -site, weighted 94 1 0.93 1 0.93 0.93 1.00 Basins and Design Points. The project site, for analysis of development hydrology, was divided into two drainage basins: the off -site basin and the project site basin, totaling 0.655 acres. A small landscaped portion of the developed site (a strip of land a few feet wide) will drain south to Spring Creek College. The table below summarizes the basin locations and areas. Basin ID Area acres Location A 0.369 1 Human Bean site OS-1 0.286 1 East half of Vision E eland property, and south half of building Two design points was used in the hydraulic design below, as summarized in the following table. Design Point Hydraulic Feature Contributing Basin(s) 1 Curb cut in parking island OS-1 2 Curb cut to pond, south curb OS-1 + A k: 0. L. Page 6 211512007 Most of the cite is currently an asphalt parking surface. Existing vegetation includes a grass berm with shrubs and trees next to College Avenue, and a few trees in the southeast corner of the site. DRAINAGE ANALYSIS The site was analyzed to determine the depth of rainfall for storms of varying frequency and the predicted rate of discharge associated with these storm events, both under historic and proposed or developed conditions. The methods used are detailed below, and all calculations are included in the Appendix to this report. RAINFALL Rainfall depths for various storm frequencies and durations were calculated using City of Fort Collins rainfall design criteria and the intensity -duration -frequency relationships that correspond to these criteria. A set of IDF curves is included in the Appendix materials. These IDF relationships can be approximated mathematically with an equation of the form: I = K /(10 + tc)x Where: I = intensity in inches/hour K = a constant which is a function of the specific IDF curve t, = time of concentration in minutes, and x = an exponent which is a function of the specific IDF curve The variables K and x can be determined for any set of known IDF curves, and were calculated for the 2, year, 5-year, 10-year and 100-year storms. The IDF equation for the 2-year storm in Fort Collins, for example, is determined to be: I = 23.7 /(10 + tc)0.791 The corresponding IDF equation for each of these four storm events is summarized in the following table: Storm Event K x 2-year 23.7 0.791 5-year 30.1 0.766 10-year 40.6 0.793 100- ear 82.9 0.793 These relationships allow the easy determination of rainfall intensity for these four storm events for any basin's calculated time of concentration. Page S 211512007 p 1 1 40' 0 - 40' NORn SCALE: 1, - 40 ❑I WS.,M190NEAM o 0 7 O w u OMOro4O HUMN u E4N/.TYRING C�FFI( R C Q a ` DATE 12I06 �v FIGURE HUMAN BEAN AT SPRING CREEK ! �C� PROJECT NO.: 36 101 2 r SITE PLAN Associates DRAWN BY: KB a/ Buckeye m Bucke N [ St St m O U E Lake St n Cl Prospect St c Deines a a ci a a Cl � Pork r n o AL O o. St Y m Alpert c a. o 0 U Ct c :EAlpert Ct 0 Cl Stuart St Spring Creek o o �eYe Johnson Dr7- V nne c Spring Pak Dr ne r Cheyenne u N Arthur ' t Dr m n E Y u Dart rh puth Y o (' G\ a D Q' O V Rutilers Ave 0 S Q Duke a o a Columbia Rd Y L) u o 0 C Cornell Ain —ve b Cam ridge Yale Way Dr Ci r VOnd N er6i i Ave Qto'� NORTH in Y ui been NTS c Y o i c Rd o Princeton Cr Rd I Y r 0 a: FIGURE HUMAN BEAN AT SPRING CREEK ` DATE I2106 QED PROJECT NO.: 36-101 VICINITY MAP Associates DRAWN BY: KB OVERALL DRAINAGE CONSIDERATIONS PROJECT DESCRIPTION The Human Bean at Spring Creek PDP is a proposed 0.37-acre commercial development to be located on the east side of South College Avenue adjacent to the existing Vision Eyeland clinic at 1820 S. College Ave. Figure 1 is a vicinity map for the project. The property, which is rectangular in shape, is situated just north of Spring Creek. The proposed project will include a drive -through coffee shop with drive aisles, and with on -site parking also provided. Figure 2 is a reduced version of the site plan. The project will be built in one construction phase. MAJOR BASIN The site is located within Fort Collins' Spring Creek Basin, which discharges into the Cache La Poudre River approximately 3 miles east of the site. EXISTING HYDRAULIC FACILITIES AND FLOOD HAZARD AREAS The southwest corner of the site is located within a flood hazard area. The adjacent mapped flood hazard area for Spring Creek is depicted on FIRM Panel 08069C0987F, Community number 080102 (see attached reference material). The portion of the property affected by the floodplain is located within the flood fringe, and not within the floodway. An approved Floodplain Use Permit will be required prior to the start of any site improvements in the floodplain, including landscape improvements. No existing irrigation facility is located on or immediately adjacent to the project. An existing area drain and 8" storm drain pipe capture storm water runoff and convey it to Spring Creek. A riprap apron has been placed at the outlet of this pipe and is observed to be stable. EXISTING TOPOGRAPHY, SOILS AND VEGETATION The site currently has a general north to south slope, with the area drain mentioned above located in a sump approximately 30 feet north of the property line. Off -site runoff flows to the property from the adjacent Vision Eyeland property. The northwest comer of the Vision Eyeland property is extremely flat, and topographic survey indicates that it will not drain to the subject property. According to the Soil Survey of Larimer County, prepared by the Soil Conservation Service (SCS, now the Natural Resources Conservation Service or NRCS), the Fort Collins loam underlies the proposed project. The Hydrologic Soil Group for this soil is Group B, corresponding to relatively slow runoff or relatively rapid percolation rates. Page 4 211512007 ENGINEER CERTIFICATION OF DRAINAGE REPORT I hereby certify that this report and attached plans for the drainage design of the Human Bean at Spring Creek PDP was prepared by me or under my direct supervision for the owners thereof and meets or exceeds the criteria in the City of Fort Collins Storm Drainage Design Criteria and Construction Standards. REG/ST l��i,,r Date Og' °°°.,° F4 : AZ °° t 9' V,7:&�q Registered Pro essional Engineer W 26325 � 0 x State of Colorado No. . .0 Page 3 211512007 / / 1 / 1 TABLE OF CONTENTS DRAINAGE AND EROSION CONTROL REPORT.................................................................................................. 1 Tableof Contents.......................................................................................................................................................... 2 Engineer Certification of Drainage Report ................................................................................................................... 3 Overall Drainage Considerations.............................................................................................................................. 4 ProjectDescription............................................................................................................................................... 4 MajorBasin.......................................................................................................................................................... 4 Existing Hydraulic Facilities and Flood Hazard Areas......................................................................................... 4 Existing Topography, Soils and Vegetation......................................................................................................... 4 DrainageAnalysis..................................................................................................................................................... 5 Rainfall................................................................................................................................................................. 5 Runoff................................................................................................................................................................... 6 Drainage Plan/Hydraulic Report ............................................................................................................................... 7 WaterQuality Detention....................................................................................................................................... 7 OpenChannels...................................................................................................................................................... 7 Pipes...................................................................................................................................................................... 7 Erosion and Sedimentation Control.......................................................................................................................... 8 Appendix ....................... .............................. 9 Page 2 211512007 CCU Associates DRAINAGE AND EROSION CONTROL REPORT For: HUMAN BEAN AT SPRING CREEK CITY OF FORT COLLINS, COLORADO ON BEHALF OF APPLICANT: PIAZZA, LLC QED ASSOCIATES 204 WALNUT STREET, SUITE C FORT COLLINS, CO 80524 FEBRUARY 169 2007 ► ► 1 204 walnut street, suite c, fort collins, co 80524 9 office: 970.416.0600 9 fax: 970.416-0601