HomeMy WebLinkAbout2439 PALOMINO DR - DISCLOSURES - 11/23/2015 (11)BUILDING LEAKAGE TEST
Date of Test: 11/23/2015 Test File: 2439 Palomino Dr - DR Horton - MP Tectite
Customer: DR Horton Technician: Tyler Stein - EnergyLogic Inc.
Project Number: 38424
Building Address: 2439 Palomino Dr
Fort Collins, CO 80525
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
2512 CFM50 (+/- 1.7 %)
2.60 ACH50
138.2 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 111.0 (+/- 29.3 %)
Exponent (n) = 0.797 ( +/- 0.077 )
Correlation Coefficient = 0.99537
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate:
2. Estimated Design Infiltration Rate:
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
146.5 CFM
0.15 ACH
18.3 CFM per person
Winter: 275.6 CFM Summer: 172.9 CFM
0.29 ACH 0.18 ACH
Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010)
Recommended Whole Bldg Rate: 97.4 CFM
Base Rate: 115.3 CFM
Infiltration Credit: <17.9 CFM>