Loading...
HomeMy WebLinkAbout2439 PALOMINO DR - DISCLOSURES - 11/23/2015 (11)BUILDING LEAKAGE TEST Date of Test: 11/23/2015 Test File: 2439 Palomino Dr - DR Horton - MP Tectite Customer: DR Horton Technician: Tyler Stein - EnergyLogic Inc. Project Number: 38424 Building Address: 2439 Palomino Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 2512 CFM50 (+/- 1.7 %) 2.60 ACH50 138.2 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 111.0 (+/- 29.3 %) Exponent (n) = 0.797 ( +/- 0.077 ) Correlation Coefficient = 0.99537 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 146.5 CFM 0.15 ACH 18.3 CFM per person Winter: 275.6 CFM Summer: 172.9 CFM 0.29 ACH 0.18 ACH Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 97.4 CFM Base Rate: 115.3 CFM Infiltration Credit: <17.9 CFM> No Text No Text No Text