HomeMy WebLinkAbout2220 MAID MARIAN CT - DISCLOSURES - 7/17/2015 (4)BUILDING LEAKAGE TEST Date of Test: 7/17/2015 Test File: 2220 Maid Marian Ct - Midtown - MP Tectite Technician: Tyler Stein - EnergyLogic Inc. Project Number: 35785 Customer: Midtown Homes Building Address: 2220 Maid Merian Ct Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1292 CFM50 ( +/- 1.0 %) (50 Pa = 0.2 w.c.) 2.36 ACH50 2. Leakage Area: 71.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 107.6 ( +/- 27.2 %) Exponent (n) = 0.635 ( +/- 0.069 ) Correlation Coefficient = 0.99694 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 61.2 CFM 0.11 ACH 20.4 CFM per person 2. Estimated Design Infiltration Rate: Winter: 86.6 CFM 0.16 ACH Summer: 63.5 CFM 0.12 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 57.2 CFM Base Rate: 57.2 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 7/17/2015 Test File: 2220 Maid Marian Ct - Midtown - MP Tectite Building Information Volume 32776 Surface Area 7323 Floor Area 3470 Height 10 # of Bedrooms 2 # of Occupants 3 Year of Construction 2015 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 12830-7 3/22/2013 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 7/17/2015 Test File: 2220 Maid Marian Ct - Midtown - MP Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 71.0 82.0 5000.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -2.8 n/a n/a -65.7 -62.3 62.9 1432 1496 0.7 Ring A -61.3 -57.9 55.9 1352 1413 -0.4 Ring A -56.5 -53.1 50.8 1291 1348 0.5 Ring A -54.4 -51.0 46.3 1234 1289 -1.4 Ring A -48.3 -44.9 40.8 1159 1211 0.3 Ring A -43.9 -40.5 35.6 1086 1134 0.3 Ring A -4.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters - Fewer than 8 data points were taken. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 7/17/2015 Test File: 2220 Maid Marian Ct - Midtown - MP Tectite Comments Connections to: Garage = -45.2 Pa Mechanicals = -50