HomeMy WebLinkAboutPRESIDIO APARTMENTS - FDP - 25-09/A - CORRESPONDENCE - (3)Ted Shepard - Presidio Apartments PDP Ted Shepard
From: Russell Hovland
To: Ted Shepard
Date: 11/10/2009 10:56:52 AM
Subject: Presidio Apartments PDP — Ted Shepard
Ted,
Here are some comments from Building Plan Review for you Presidio Apartments PDP meeting.
The following 2006 IBC code requirements would likely affect these 3 story R-2 buildings:
1. Fire sprinkler system required per chap 9.
2. 1-hour dwelling units sep walls/floors required.
3. Our local amendment to section 1026 requires egress windows from sleeping rooms even in a
sprinkled building.
4. Keep the buildings 20 feet apart from each other to avoid wall protection issues per chap 6.
5. Radon reduction system required.
6. Accessible dwelling units are required by chapl 1 and state statute CRS 9-5.
Please remember to schedule a Pre -submittal code review meeting in the mid design stage of the project
Russ Hovland
Plans Examiner
Community Development & Neighborhood Services
City of Fort Collins
Direct 970-416-2341
rhovland@fcgov.com
CC: Lisa Schoenfeld; Mike Gebo; Steve Dush