Loading...
HomeMy WebLinkAbout2945 JOSEPH DR - DISCLOSURES - 6/19/2015 (4)BUILDING LEAKAGE TEST GS Services Ltd 2000 S. College Ave #308 Fort Collins, CO 80525 Date of Test: 6/19/2015 Test File: Savant Homes- 2945 Joseph Dr. - bd ma Technician: Project Number: Customer: Savant Homes Building Address: 2945 Joseph Dr. Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1194 CFM50 ( +/- 3.6 %) (50 Pa = 0.2 w.c.) 2.96 ACH50 2. Leakage Area: 65.7 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 16.3 ( +/- 26.0 %) Exponent (n) = 1.097 ( +/- 0.072 ) Correlation Coefficient = 0.99786 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 67.5 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 108.8 CFM 0.27 ACH Summer: 72.2 CFM 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 6/19/2015 Test File: Savant Homes- 2945 Joseph Dr. - bd ma Building Information Volume 24170 Surface Area Floor Area 2720 Height 18 # of Bedrooms 5 # of Occupants Year of Construction 2014 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 6/19/2015 Test File: Savant Homes- 2945 Joseph Dr. - bd ma Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 78.0 88.0 5000.0 Data Points - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.8 n/a n/a -63.4 -61.5 44.6 1211 1441 -3.9 Ring A -56.1 -54.2 35.7 1087 1293 -0.9 Ring A -50.3 -48.4 27.9 964 1147 -0.5 Ring A -44.6 -42.7 213.8 866 1030 2.6 Ring B -38.6 -36.7 153.1 734 873 2.7 Ring B -32.3 -30.4 103.0 603 717 3.7 Ring B -26.2 -24.3 59.4 459 546 0.9 Ring B -19.8 -17.9 27.1 311 370 -4.4 Ring B -2.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test - Test Parameters None - * n value outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 6/19/2015 Test File: Savant Homes- 2945 Joseph Dr. - bd ma Comments House wrt garage = -46.1 pa