HomeMy WebLinkAbout2202 MAID MARIAN CT - DISCLOSURES - 1/16/2015BUILDING LEAKAGE TEST Date of Test: 1/16/2015 Test File: 2202 Maid Marian Ct-Multi Point Tectite Technician: Justin Heldenbrand Project Number: EnergyLogic (33680) Customer: Midtown Homes Building Address: 2202 Maid Marian Ct Fort Collins, CO 80524 Test Results 1. Airflow at 50 Pascals: 1098 CFM50 ( +/- 0.2 %) (50 Pa = 0.2 w.c.) 2.15 ACH50 2. Leakage Area: 60.4 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 92.2 ( +/- 4.5 %) Exponent (n) = 0.633 ( +/- 0.011 ) Correlation Coefficient = 0.99984 4. Test Settings: Test Standard: RESNET Multi-Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 52.0 CFM 0.10 ACH 13.0 CFM per person 2. Estimated Design Infiltration Rate: Winter: 73.6 CFM 0.14 ACH Summer: 54.0 CFM 0.11 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 61.8 CFM Base Rate: 61.8 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 1/16/2015 Test File: 2202 Maid Marian Ct-Multi Point Tectite Building Information Volume 30681 Surface Area 6854 Floor Area 3183 Height 10 # of Bedrooms 3 # of Occupants 4 Year of Construction 2015 Wind Shield M Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) - Micromanometer Energy Conservatory DG700 275-7 10/31/2014 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 1/16/2015 Test File: 2202 Maid Marian Ct-Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 70.0 39.0 5003.0 Data Points Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) % Error Fan Configuration -1.1 n/a n/a -67.6 -66.5 55.7 1349 1316 0.0 Ring A -64.9 -63.8 52.7 1314 1281 0.0 Ring A -61.8 -60.7 49.3 1271 1240 -0.1 Ring A -58.0 -56.9 45.3 1220 1190 -0.2 Ring A -55.0 -53.9 42.6 1184 1154 0.2 Ring A -51.0 -49.9 38.5 1127 1099 0.2 Ring A -48.5 -47.5 35.9 1090 1062 0.0 Ring A -45.3 -44.3 32.6 1040 1014 -0.2 Ring A -1.0 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 1/16/2015 Test File: 2202 Maid Marian Ct-Multi Point Tectite Comments Connection to: Mechanicals -50pa Sales Office/Garage should be tested once the supply ducts have been removed and the space turned back into a garage