Loading...
HomeMy WebLinkAbout1439 FRONT NINE DR - SPECIAL INSPECTIONS - 5/19/2015May 19, 2015 Dan Fender Re: 1439 Front Nine Drive Fort Collins, Colorado wialams a Gl55OC=Ell T122S STRUCTURAL ENGINEERS OIC- /�C� %3IJ v 389i As requested I have reviewed the requirements for removing a portion of the following bearing wall between the kitchen and dining area at the referenced site. DISCUSSION & RECOMMENDATIONS The structure is a wood frame residence with a basement foundation An approximate 101/2' opening between the kitchen and dining area is planned. The wall supports the trusses over the kitchen. Based on the span and design load it is recommended a (2)-1 3/4"x 9 1/2" beam be used at the opening. The beam should be supported on a 2-2x4 post at each end. Solid blocking should be provided in the joist space below over the top of the existing basement beam. GENERAL COMMENTS This report has been prepared based on observations of the portions of the structure visible and with generally accepted engineering practices in the area. Should different information become available the opinions and recommendations contained in this report should be reviewed and modified or supplemented as necessary. No warranty or guarantee, express or implied, is made or intended by this written or any oral report. If I can be of further assistance please contact me. Sincerely, �h \ c�J(1 RI WSO. We s & Ass.oitesy l�ip.5 23C i iP ary G. We'eks,''P.E. tructural En'g n$,er......... z 4730 South College Ave, Suite 201, Fort Collins, CO 80525 Phone (970) 225.2422 - Fax (970) 225.2622 1)