Loading...
HomeMy WebLinkAbout4700 LADY MOON DR - SPECIAL INSPECTIONS - 1/26/2015GROUND January 26, 2015 v� 3 v y 7 32 ENGINEERING Subject: Materials Testing, Building Summary Letter, Banner -Fort Collins Medical Center, Fort Collins, Colorado Job Number. 13-0605 Permit Number: b1304738 Mr. Mark Ostrand Banner Health Development and Construction 1801 16t' Street Greeley, CO 80631 Attn: Mr. Ostrand, This letter summarizes the materials testing Ground Engineering Consultants, Inc. (GROUND) performed during the construction of the Banner — Fort Collins Medical Center located at the southeast corner of the intersection of East Harmony Road and Lady Moon Drive (4700 Lady Moon Drive, Fort Collins, CO 80528). The materials testing was performed on a part-time basis at times scheduled by the owner, owner's representative, contractor, and/or subcontractor. During construction, representatives of our office observed reinforcing steel placement and performed testing on the structural concrete placed for the footings, foundation walls, and floor slabs. The structural concrete was tested to determine physical properties and compressive strength. In addition, representatives of our office were on -site to periodically observe the reinforcing steel and grout placement during construction of the structural masonry walls for screen wall. Nuclear moisture density testing was periodically performed on the structural fill soils and bearing soils during the building excavation and backfill to determine percent compaction and in -place moisture content. Laboratory testing included the determination of moisture and density relationship and soils classification. A Certified Welding Inspector (CWI) was on -site to observe field welded and bolted connections. Observations were performed during the erection of the structural steel. In addition, representatives of our office observed spray applied fireproofing for thickness, density, and adhesion to structural steel members. Based on the test results and to the best of our knowledge, it is our opinion that the materials tested as outlined above for soil compaction, concrete, reinforcing steel, structural masonry walls, fireproofing, and structural steel welded and bolted connections were in general accordance with project plans and specifications. The materials testing as indicated above was periodically performed to provide data to the Owner, Contractor, and Subcontractors to assist them in evaluating the general compliance of the tested materials and/or work with the contract documents at the times of our observation and testing. We did not supervise, direct or have any control over the Contractor's work. We LOVELAND OFFICE 2468 East 9th Street I Loveland, CO 80537 1 (970) 622-0800 1 www.groundeng.com ENGLEWOOD i COMMERCE CITY i LOVELAND I GRANBY I GYPSUM Banner— Fort Collins Medical Center Fort Collins, Colorado were not responsible for the Contractor's means, methods, procedures, techniques, or sequences of construction, nor responsible for Contractor to carry out the work in accordance with the contract documents. If you have any questions concerning this letter, please contact our office. Sincerely, Ground Engineering Consultants, Inc. Kelsey Van DN:cnydgnedby RelseyVan Bemmel DN:m=Kelseyinn Bng Con a=Ground Engineering Consultants, ou=lvoland Nq lAek,pard ernnne BemmeI s.00m k� yvanbemmeipgrounden Date: 2015.011611:06:56-0TW r, Kelsey Van BemmeI, P.E. Job No. 13-0604 Ground Engineering Consultants, Inc. Page 2 of 2