HomeMy WebLinkAbout4809 PRAIRIE VISTA DR - DISCLOSURES - 5/11/2015BUILDING LEAKAGE TEST Date of Test: 5/11/2015 Test File: 4809 Prairie Vista Dr Multi Point Tectite Customer: Philgreen Construction Technician: Brad Smith - EnergyLogic Project Number: 35400 Building Address: 4809 Prairie Vista Dr Fort Collins, CO 80526 Test Results 1. Airflow at 50 Pascals: 855 CFM50 (+/- 0.8 %) (50 Pa = 0.2 w.c.) 1.71 ACH50 2. Leakage Area: 47.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 56.0 (+/-19.7 %) Exponent (n) = 0.697 ( +/- 0.049 ) Correlation Coefficient = 0.99752 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 49.9 CFM 0.10 ACH 10.0 CFM per person 2. Estimated Design Infiltration Rate: Winter: 93.8 CFM Summer: 58.9 CFM 0.19 ACH 0.12 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 68.6 CFM Base Rate: 68.6 CFM Infiltration Credit: <0.0 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/11/2015 Test File: 4809 Prairie Vista Dr Multi Point Tectite Building Information Location Climate Information Volume 30010 Surface Area 6940 Floor Area 3114 Height 20 # of Bedrooms 4 # of Occupants 5 Year of Construction 2015 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 13013-7 1 4/16/2015 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/11/2015 Test File: 4809 Prairie Vista Dr Multi Point Tectite Depressurization Test: Environmental Data Indoor Temperature ff) Outdoor Temperature (°F) Altitude (ft) 69.0 57.0 5003.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -3.4 n/a n/a -69.3 -66.4 32.0 1030 1044 0.1 Ring A -67.8 -64.9 30.4 1005 1018 -0.7 Ring A -63.7 -60.7 28.0 965 978 -0.2 Ring A -60.0 -57.1 25.9 929 941 0.3 Ring A -57.9 -55.0 239.7 916 929 1.6 Ring B -52.8 -49.9 199.3 836 848 -0.7 Ring B -49.9 -47.0 184.9 806 817 -0.3 Ring B -47.3 -44.4 171.8 777 788 0.0 Ring B -2.5 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None I BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/11 /2015 Test File: 4809 Prairie Vista Dr Multi Point Tectite Connection to: Garage: -46.1 Mechanicals: -50 Pa Comments