Loading...
HomeMy WebLinkAbout2121 SCARECROW RD - DISCLOSURES - 3/7/2014BUILDING LEAKAGE TEST GS Service GS"Sbudoes 2000 S College Ave. Suite 308 Fort Collins, CO 80525 I;9� 0617(. Date of Test: 3/7/2014 Test File: Bellisimo Construction 2121 Scarecrow Rd -Unit C - BD Customer: Bellisimo Technician: Project Number: Unit C Fort Collins, CO 80526 Building Address: Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1379 CFM50 ( +/- 2.6 %) (50 Pa = 0.2 w.c.) 5.04 ACH50 2. Leakage Area: 75.9 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 61.8 (+/- 22.0 %) Exponent (n) = 0.794 ( +/- 0.060 ) Correlation Coefficient = 0.99717 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 77.9 CFM 0.28 ACH 2. Estimated Design Infiltration Rate: Winter: 125.6 CFM Summer: 83.4 CFM 0.46 ACH 0.30 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman DN: CN = Paul Higman,;,Higrnan C = US Date. 2014.12.23 09: 58:04-06'00' CiS�S�er�ces gUILDING LEAKAGE TEST Page 2 of 4 �_ , ,::..� � �, � �- Date of Test: 3/7/2014 Test File: Bellisimo Construction 2121 Scarecrow Rd ±�ni�C���BD� ��� ��� � � � �—.i � ,e.- ,,.:.�„ W Building Information Location Climate Information Volume 16435 Ventilation Weather Factor 0.87 SurtaceArea Energy Ciimate Factor 17.00 FloorArea 1760 Heating Degree Days 6128 Height 18 Cooling Degree Days 297 #of Bedrooms 3 Design Winter Wind Speed 7.3 mph #of Occupants Design Summer Wind Speed 9.4 mph Year of Construction 2014 � Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost I Heating Efficiency% Cooling Fuel Cost Coaling SEER Equipment Information Type Manufacturer Model Serial Number � Custom Calibration Date Fan Energy Conservatory Model 3 (110� i Default Micromanometer Energy Conservatory DG700 I r � GS 5eryices �1--=- - BUILDING LEAKAGE TEST Page 3 of 4 � Date of Test: 3/7/2014 Test File: Bellisimo Construction 2121 Scarecrow Rd-Unit,,`C�S B �� „��_ � � � � � � � ,__) ��, � Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) Altitude(ft) 68.0 45.0 5000.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration 0.1 n/a n/a -66.1 -66.0 86.2 1670 1666 -3.2 Ring A -58.4 -58.4 73.8 1548 1544 -1.0 Ring A -51.0 -51.0 64.3 1448 1444 3.1 Ring A -43.6 -43.6 47.4 1248 1245 0.7 Ring A -34.3 -34.3 33.3 1051 1048 2.6 Ring A -31.4 -31.3 28.3 970 967 1.6 Ring A -28.1 -28.1 211.8 862 860 -1.4 Ring B -21.3 -21.3 133.2 685 683 -2.3 Ring B -0.2 n/a n/a TimeAveraging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None 1 ` GS��Ser�tices BUILDING LEAKAGE TEST Page 4 of 4 .:_, r..,� , �, � ,f __ �.-� -- �� ` � Date of Test: 3/7/2014 Test File: Bellisimo Construction 2121 Scarecrow Rd -Unit��'�BD�j � � � � L" �_;..\� ,�� ri.� � Comments House WRT Garage=-46.1 pa Targets: 3.Oach50= <817 cfm50 4.Oach50= <1089 cfm50 0.3cfm per s.f. of surface area= <1455 cfm50