Loading...
HomeMy WebLinkAbout2110 NANCY GRAY AVE - DISCLOSURES - 11/6/2014 (9)4 p g BUILDING LEAKAGE TEST Q�P�r QQ ec GS Services to 7 V V 2000 S College Ave. #308 Fort Collins, CO 80525 Date of Test: 11/6/2014 Test File: Bellisi o Construction - 2110 Nancy Gray - UnitA-bd1 Customer: Bellisimo Construction Inc Technician: Paul Higman Project Number: Fort Collins, CO 80526 Building Address: UnitA 2110 Nancy Gray Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1327 CFM50 (+/-1.8 %) (50 Pa = 0.2 w.c.) 4.79 ACH50 y� 2. Leakage Area: 73.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 96.7 (+/-12.4 %) Exponent (n) = 0.670 ( +/- 0.034 ) Correlation Coefficient = 0.99867 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 75.0 CFM 0.27 ACH 2. Estimated Design Infiltration Rate: Winter: 120.9 CFM Summer: 80.2 CFM 0.44 ACH 0.29 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating 2. Estimated Cost of Air Leakage for Cooling Digitally signed by: Paul Paul Higman D:,,CN = Paul Higman Higman a(eU2014.11.1013: 06:26-06'00' GSfSetiqes L -J ✓ ''_J `,J I� i �=— BUILDING LEAKAGE TEST Page 2 of 4 J Date of Test: 11/6/2014 Test File: BeIIisimo Construction - 2110 Nancy Gray - UnitA-bd1 Building Information Location Climate Information Volume 16609 Surface Area Floor Area 1622 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 No Text No Text No Text