HomeMy WebLinkAbout2050 YEARLING DR - DISCLOSURES - 5/7/2015BUILDING LEAKAGE TEST Date of Test: 5/7/2015 Test File: 2050 Yearling Dr - DR Horton - MP Tectite Customer: DR Horton Technician: Tyler Stein - EnergyLogic Inc. Project Number: 34953 Building Address: 2050 Yearling Dr Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 2145 CFM50 (+/- 1.9 %) (50 Pa = 0.2 w.c.) 2.22 ACH50 2. Leakage Area: 118.0 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 207.0 (+/- 39.0 %) Exponent (n) = 0.598 ( +/- 0.101 ) Correlation Coefficient = 0.98591 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 141.3 CFM 0.15 ACH 23.5 CFM per person 2. Estimated Design Infiltration Rate: Winter: 235.2 CFM Summer: 147.6 CFM 0.24 ACH 0.15 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate: 85.0 CFM Base Rate: 100.3 CFM Infiltration Credit: <15.3 CFM> BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/7/2015 Test File: 2050 Yearling Dr- DR Horton-MP Tectite Building Information Location Climate Information Volume 57918 Ventilation Weather Factor 0.87 Surtace Area 10211 Energy Climate Factor 17.00 FloorArea 5533 Heating Degree Days 6128 Height 30 Cooling Degree Days 297 #of Bedrooms 5 Design Winter Wind Speed 7.3 mph #of Occupants 6 Design Summer Wind Speed 9.4 mph Year of Construction 2015 Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110� Default Micromanometer Energy Conservatory DG700 12830-7 3/22/2013 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/7/2015 Test File: 2050 Yearling Dr- DR Horton- MP Tectite Depressurization Test: Environmental Data Indoor Temperature(°F) Outdoor Temperature (°F) Altitude(ft) 60.0 48.0 5000.0 Data Points Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.2 n/a n/a -58.8 -56.9 166.8 2304 2296 -0.9 Ring A -59.7 -57.7 161.1 2266 2257 -3.4 Ring A -55.7 -53.7 165.8 2298 2289 2.3 Ring A -52.3 -50.4 153.4 2212 2204 2.3 Ring A -48.1 -46.1 133.7 2069 2061 0.8 Ring A -43.7 -41.7 117.6 1943 1936 0.5 Ring A -40.3 -38.3 104.8 1837 1830 0.0 Ring A -36.3 -34.3 88.5 1692 1686 -1.5 Ring A -1.7 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None - 'correlation coefficient outside of normally accepted limits. * n value and/or correlation coefficient limits are not officially part of the RESNET Multi-Point Test Standard. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/7/2015 Test File: 2050 Yearling Dr- DR Horton- MP Tectite Comments Connections to: Garage =-45.2 Pa Mechanicals=-50