HomeMy WebLinkAbout2814 EXMOOR LN - DISCLOSURES - 1/27/2015g s r41N
r
F
GO,.rv'
Date of Test: 1/27/2015
Customer: Journey Homes
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
Infiltration Estimates
BUILDING LEAKAGE TEST
GS Services Ltd
2000 South College Ave #308
Fort Collins, Co 80525
Test File: Journey Homes -2814 Exmoor - BD2
Technician: Paul Higman
Project Number:
Building Address: 2814 Exmoor Lane
Fort Collins, CO 80525
1532 CFM50 (+/- 2.3 %)
2.98 ACH50
84,3 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 33.0 ( +/- 18.3 %)
Exponent (n) = 0.981 ( +/- 0.050 )
Correlation Coefficient = 0.99836
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
1. Estimated Average Annual Infiltration Rate: 76.7 CFM
0.15ACH
2. Estimated Design Infiltration Rate: Winter: 139.6 CFM Summer: 92.6 CFM
0.27 ACH 0.18 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Digitally signed by:
Paul
Paul Higman
DN itN = Paul
Hi mane'fll
""*9', nC=US
_..1 Date: 2015.02.02 16:
t d29-06'00'
V
GSA rcS BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 1/27/2015 Test File: Journey Homes -2814 ExmooriJ.D , �h �.n� r A [)�
Building Information Location Climate Information
Volume
30843
Surface Area
Floor Area
3427
Height
12
# of Bedrooms
3
# of Occupants
Year of Construction
2014
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
19028-7
�� SBNIS
�,� BUILDING LEAKAGE TEST Page 3 of 4
Ur+% Date of Test: 1/27/2015 Test File: JourneyHomes -2814 Exmor - BD2 fir'
G.7
Depressurization Test:
Environmental Data
Indoor Temperature (A°F)
Outdoor Temperature (A°F)
Altitude (ft)
62.0
40.0
4980.0
Data Points - Data Entered Manually
Nominal Baseline Adjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-0.8
n/a
n/a
-61.1
-60.2
100.3
1798
1794
-2.4
Ring A
-55.6
-54.7
86.2
1670
1667
-0.4
RingA
-49.9
-49.0
68.8
1496
1493
-0.6
RingA
-46.1
-45.2
59.2
1391
1388
0.0
RingA
-40.7
-39.8
47.0
1243
1240
1.3
Ring A
-36.0
-35.1
37.8
1118
1116
3.0
Ring A
-30.7
-29.8
256.1
947
945
2.5
Ring B
-26.2
-25.3
176.7
788
786
0.1
Ring B
-20.7
-19.8
101.3
598
597
-3.4
Ring B
-1.0
n/a
n/a
Time Averaging Period: 10
Deviations from Standard RESNET Multi -Point Test - Test Parameters
None
$ YB k
GS �eiS
BUILDING LEAKAGE TEST Page 4 of 4
Date of Test: 1/27/2015 Test File: Journey Homes -2814 Exmoor -BD2
Comments
House WRT Garage =-45.8pa