Loading...
HomeMy WebLinkAbout2814 EXMOOR LN - DISCLOSURES - 1/27/2015g s r41N r F GO,.rv' Date of Test: 1/27/2015 Customer: Journey Homes Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level Infiltration Estimates BUILDING LEAKAGE TEST GS Services Ltd 2000 South College Ave #308 Fort Collins, Co 80525 Test File: Journey Homes -2814 Exmoor - BD2 Technician: Paul Higman Project Number: Building Address: 2814 Exmoor Lane Fort Collins, CO 80525 1532 CFM50 (+/- 2.3 %) 2.98 ACH50 84,3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 33.0 ( +/- 18.3 %) Exponent (n) = 0.981 ( +/- 0.050 ) Correlation Coefficient = 0.99836 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test 1. Estimated Average Annual Infiltration Rate: 76.7 CFM 0.15ACH 2. Estimated Design Infiltration Rate: Winter: 139.6 CFM Summer: 92.6 CFM 0.27 ACH 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman DN itN = Paul Hi mane'fll ""*9', nC=US _..1 Date: 2015.02.02 16: t d29-06'00' V GSA rcS BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 1/27/2015 Test File: Journey Homes -2814 ExmooriJ.D , �h �.n� r A [)� Building Information Location Climate Information Volume 30843 Surface Area Floor Area 3427 Height 12 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 �� SBNIS �,� BUILDING LEAKAGE TEST Page 3 of 4 Ur+% Date of Test: 1/27/2015 Test File: JourneyHomes -2814 Exmor - BD2 fir' G.7 Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 62.0 40.0 4980.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -0.8 n/a n/a -61.1 -60.2 100.3 1798 1794 -2.4 Ring A -55.6 -54.7 86.2 1670 1667 -0.4 RingA -49.9 -49.0 68.8 1496 1493 -0.6 RingA -46.1 -45.2 59.2 1391 1388 0.0 RingA -40.7 -39.8 47.0 1243 1240 1.3 Ring A -36.0 -35.1 37.8 1118 1116 3.0 Ring A -30.7 -29.8 256.1 947 945 2.5 Ring B -26.2 -25.3 176.7 788 786 0.1 Ring B -20.7 -19.8 101.3 598 597 -3.4 Ring B -1.0 n/a n/a Time Averaging Period: 10 Deviations from Standard RESNET Multi -Point Test - Test Parameters None $ YB k GS �eiS BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 1/27/2015 Test File: Journey Homes -2814 Exmoor -BD2 Comments House WRT Garage =-45.8pa