Loading...
HomeMy WebLinkAbout328 REMINGTON ST - SPECIAL INSPECTIONS - 11/14/2014KL&A, Inc. Structural Engineers and Builders 421 East Fourth Street, Loveland, CO 80537 Ph: 970-667-2426 Fax: 970-667-2493 November 14, 2014 Jason McConahy Mountain View Community Church 328 Remington Street Fort Collins, CO 80524 Re: Storage to Office Renovation Dear Mr. McConahy: The purpose of this letter is to state that we have reviewed the existing balcony wood framing of the building located at 328 Remington Street in Fort Collins, CO along with the proposed floor framing plan for the new office in this area. Our review consisted of the following, a site observation, review of the proposed framing, and structural calculations. The proposed office floor framing will sit approximately 2'-6" above the existing balcony floor and will consist of wood joists spanning to wood knee walls bearing on the existing floor. Based on our review, the existing structure is adequate to support the additional dead load of the office floor and wall framing along with the 50 psf office live load. We recommend that the office floor be framed with APA span rated 24" oc sheathing (23/32" nominal thickness) over 2x8 Hem Fir No.2 floor joists at 16" OC. 2x4 studs at 24" OC are acceptable for the proposed knee wall and office wall framing. This review is based on field observation performed by KL&A, Inc. on 11/13/2014. No material testing or destructive testing was performed. This review was prepared in accordance with the standard of care for engineering practice. No warranties are provided, either express or implied. If you have any questions, please feel free to call. Sincerely, Christopher S. Kendall, P.E. Project Manager CW�MluidADo 'S� T.e Rciew Lmc 141114d