Loading...
HomeMy WebLinkAbout2037 SCARECROW RD - DISCLOSURES - 4/1/2015 (9)GS"S'erv'��e� BUILDING LEAKAGE TEST GS Service 2000 S College Ave. Suite 308 Fort Collins, CO 80525 01400790 Date of Test: 4/1/2015 Test File: Bellisimo Construction - 2037 Scarecrow - Unit C - BD Customer: Bellisimo Technician: Project Number: Unit C Fort Collins, CO 80526 Building Address: 2037 Scarecrow Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1270 CFM50 (+ - 2.4 %) (50 Pa = 0.2 w.c.) 4.64 ACH50 2. Leakage Area: in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 92.9 (+/- 18.7 %) Exponent (n) = 0.668 ( +/- 0.051 ) Correlation Coefficient = 0.99705 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 71.8 CFM 0.26 ACH 2. Estimated Design Infiltration Rate: Winter: 115.7 CFM 0.42 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Summer: 76.8 CFM 0.28 ACH Digitally signed by: Paul Paul Higman DN:;CN = Paul Higman C Higman �� Date. 2015.04.0312:09: 53-06'00' GS Services BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/1/2015 Test File: Bellisimo Construction - 2037 Scarecrow - Unit ;BD i�� , jo Building Information Location Climate Information Volume 16435 Surface Area Floor Area 1760 Height . 18 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 19028-7 9/9/2014 GS Sertices =-- - BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/1/2015 Test File: Bellisimo Construction - 2037 Scarec v✓Un tom. �a� Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 66.0 64.0 5000.0 Data Points Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.0 n/a n/a -60.4 -59.8 58.5 -54.5 -53.8 51.8 -48.7 -48.1 44.2 -42.5 -41.8 37.7 -36.8 -36.2 31.6 -31.4 -30.8 222.1 -26.8 -26.1 170.7 -19.6 -19.0 123.3 -0.3 n/a n/a Time Averaging Period: 0 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1382 1417 -1.0 Ring A 1302 1336 0.1 Ring A 1206 1237 -0.1 Ring A 1116 1145 1.6 Ring A 1024 1050 2.6 Ring A 882 905 -1.4 Ring B 774 794 -3.5 Ring B 659 676 1.8 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters GS Services BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4/1/2015 Test File: Bellisimo Construction - 2037 Scarecrow - Unit C - BD Comments D) cu House WRT Garage =-45.5pa