HomeMy WebLinkAbout2061 SCARECROW RD - DISCLOSURES - 2/17/2015BUILDING LEAKAGE TEST GS Services Ltd 2000 S College Ave. Suite 308 Fort Collins, CO 80525 Date of Test: 2/17/2015 Test File: Bellisimo Construction - 2061 Scarecrow - Unit B - BD Customer: Bellisimo Construction Inc. Technician: Phil Seitz Project Number: Unit B Fort Collins, CO 80526 Building Address: 2061 Scarecrow Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: +/- 1.4 %) (50 Pa = 0.2 w.c.) 5.39 ACH50 2. Leakage Area: 4.5 in2 LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 71.1 (+/- 9.6 %) Exponent (n) = 0.717 ( +/- 0.027 ) Correlation Coefficient = 0.99930 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 66.3 CFM 0.30 ACH 2. Estimated Design Infiltration Rate: Winter: 106.9 CFM Summer: 70.9 CFM 0.49 ACH 0.33 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Philip DWCNP ePhilip Seitz email =S V I tZf D DaIte: 201 03 318: 14:24-07'00' to, BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/17/2015 Test File: Bellisimo Construction-2061 Scarecrow-Unit B-BD Building Information Location Climate Information Volume 13052 Ventilation Weather Factor 0.87 SurfaceArea Energy Climate Factor 17.00 FloorArea 1305 Heating Degree Days 6128 Height 18 Cooling Degree Days 297 #of Bedrooms 3 Design Winter Wind Speed 7.3 mph #of Occupants Design Summer Wind Speed 9.4 mph Year of Construction 2014 Design Winter Temp Diff 73 deg F Wind Shield M Design SummerTemp Diff 15 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110� Default BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/17/2015 Test File: Bellisimo Construction-2061 Scarecrow- Unit B-BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) Altitude(ft) 62.0 20.0 5000.0 Data Points Nominal BaselineAdjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -3.8 n/a n/a -63.8 -59.1 59.1 1390 1314 -0.6 Ring A -57.9 -53.2 51.0 1292 1222 -0.4 Ring A -51.9 -47.1 43.1 1191 1127 0.2 Ring A -46.1 -41.4 34.8 1073 1015 -1.0 Ring A -39.2 -34.4 27.6 958 906 0.9 Ring A -33.8 -29.0 209.9 858 811 2.1 Ring B -27.0 -22.3 138.7 699 661 0.5 Ring B -21.8 -17.1 90.4 565 534 -1.6 Ring B -5.7 n/a n/a Time Averaging Period: 0 Deviations from Standard RESNET Multi-Point Test-Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test:2/17/2015 Test File: Bellisimo Construction-2061 Scarecrow-Unit B-BD Comments House WRT Garage=-45.6 pa Targets: 4.Oach50=<870